These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 17272302)

  • 21. The force attenuation provided by hip protectors depends on impact velocity, pelvic size, and soft tissue stiffness.
    Laing AC; Robinovitch SN
    J Biomech Eng; 2008 Dec; 130(6):061005. PubMed ID: 19045534
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Acceptance of hip protectors for hip fracture prevention in nursing homes.
    Hubacher M; Wettstein A
    Osteoporos Int; 2001; 12(9):794-9. PubMed ID: 11605747
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Force reduction by an external hip protector on the human hip after falls.
    Wiener SL; Andersson GB; Nyhus LM; Czech J
    Clin Orthop Relat Res; 2002 May; (398):157-68. PubMed ID: 11964646
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Prevention with hip protectors. Biomechanical aspects in falls and hip fractures].
    Lauritzen JB
    Nord Med; 1996 Dec; 111(10):340-3. PubMed ID: 8992465
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Utilization of external hip protectors in frail elderly residents of nursing homes].
    Mendelson G; Ben-Israel J
    Harefuah; 2005 Feb; 144(2):112-4, 150. PubMed ID: 16128016
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact experiments of an external hip protector in young volunteers.
    Parkkari J; Kannus P; Heikkilä J; Poutala J; Heinonen A; Sievänen H; Vuori I
    Calcif Tissue Int; 1997 Apr; 60(4):354-7. PubMed ID: 9075632
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Assessing the safety and effectiveness of hip protectors.
    Minns J; Dodd C; Gardner R; Bamford J; Nabhani F
    Nurs Stand; 2004 Jun 9-15; 18(39):33-8. PubMed ID: 15214118
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Hip fracture with correctly positioned external hip protector.
    Specht-Leible N; Oster P
    Age Ageing; 1999 Sep; 28(5):497. PubMed ID: 10529047
    [No Abstract]   [Full Text] [Related]  

  • 29. [Hip protectors in prevention of proximal femoral fracture].
    Conzelmann M
    Ther Umsch; 2002 Jul; 59(7):359-65. PubMed ID: 12185952
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prevention of hip fractures by external hip protectors: a randomized controlled trial.
    van Schoor NM; Smit JH; Twisk JW; Bouter LM; Lips P
    JAMA; 2003 Apr; 289(15):1957-62. PubMed ID: 12697798
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Will elderly rest home residents wear hip protectors?
    Villar MT; Hill P; Inskip H; Thompson P; Cooper C
    Age Ageing; 1998 Mar; 27(2):195-8. PubMed ID: 16296679
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of a new design of hip protectors using finite element analysis and mechanical tests.
    Schmid Daners M; Wullschleger L; Derler S; Schmitt KU
    Med Eng Phys; 2008 Nov; 30(9):1186-92. PubMed ID: 18424166
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.
    Tadano S; Nakatsuchi H; Goto N; Fujisaki K; Nakatsuchi Y
    Biomed Mater Eng; 2011; 21(4):235-46. PubMed ID: 22182791
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Compliance with external hip protectors in nursing homes in Norway.
    Forsén L; Sandvig S; Schuller A; Søgaard AJ
    Inj Prev; 2004 Dec; 10(6):344-9. PubMed ID: 15583255
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Efficacy of a specially designed hip protector for hip fracture prevention and compliance with use in elderly Hong Kong Chinese.
    Woo J; Sum C; Yiu HH; Ip K; Chung L; Ho L
    Clin Rehabil; 2003 Mar; 17(2):203-5. PubMed ID: 12625661
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Factors affecting adherence to use of hip protectors amongst residents of nursing homes--a correlation study.
    O'Halloran PD; Cran GW; Beringer TR; Kernohan G; Orr J; Dunlop L; Murray LJ
    Int J Nurs Stud; 2007 Jul; 44(5):672-86. PubMed ID: 16487529
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Test systems for the biomechanical evaluation of hip protectors: a systematic review.
    Yahaya SA; Ripin ZM; Ridzwan MIZ
    Osteoporos Int; 2020 Jan; 31(1):43-58. PubMed ID: 31446442
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Acceptability and compliance with hip protectors in community-dwelling women at high risk of hip fracture.
    Patel S; Ogunremi L; Chinappen U
    Rheumatology (Oxford); 2003 Jun; 42(6):769-72. PubMed ID: 12730537
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Older adults' perceptions of wearable technology hip protectors: implications for further research and development strategies.
    Hall A; Boulton E; Stanmore E
    Disabil Rehabil Assist Technol; 2019 Oct; 14(7):663-668. PubMed ID: 30371132
    [No Abstract]   [Full Text] [Related]  

  • 40. The Amsterdam Hip Protector Study: compliance and determinants of compliance.
    van Schoor NM; Asma G; Smit JH; Bouter LM; Lips P
    Osteoporos Int; 2003 Jun; 14(4):353-9. PubMed ID: 12730735
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.