These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 17275614)

  • 1. Automatic 3D tracking of cardiac material markers using slice-following and harmonic-phase MRI.
    Sampath S; Prince JL
    Magn Reson Imaging; 2007 Feb; 25(2):197-208. PubMed ID: 17275614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of human myocardial dynamics using virtual markers based on magnetic resonance imaging.
    Kvitting JP; Sigfridsson A; Wigström L; Bolger AF; Karlsson M
    Clin Physiol Funct Imaging; 2010 Jan; 30(1):23-9. PubMed ID: 19780762
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.
    Herold V; Mörchel P; Faber C; Rommel E; Haase A; Jakob PM
    Magn Reson Med; 2006 May; 55(5):1058-64. PubMed ID: 16596630
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia.
    Arai AE; Gaither CC; Epstein FH; Balaban RS; Wolff SD
    Magn Reson Med; 1999 Jul; 42(1):98-109. PubMed ID: 10398955
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation.
    Rogers WJ; Shapiro EP; Weiss JL; Buchalter MB; Rademakers FE; Weisfeldt ML; Zerhouni EA
    Circulation; 1991 Aug; 84(2):721-31. PubMed ID: 1860217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feedback-assisted three-dimensional reconstruction of the left ventricle with MRI.
    Swingen CM; Seethamraju RT; Jerosch-Herold M
    J Magn Reson Imaging; 2003 May; 17(5):528-37. PubMed ID: 12720262
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fast tracking of cardiac motion using 3D-HARP.
    Pan L; Prince JL; Lima JA; Osman NF
    IEEE Trans Biomed Eng; 2005 Aug; 52(8):1425-35. PubMed ID: 16119238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 3D myocardial tissue tracking with slice followed cine DENSE MRI.
    Spottiswoode BS; Zhong X; Lorenz CH; Mayosi BM; Meintjes EM; Epstein FH
    J Magn Reson Imaging; 2008 May; 27(5):1019-27. PubMed ID: 18425823
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-directional myocardial motion assessed using 3D phase contrast MRI.
    Kvitting JP; Ebbers T; Engvall J; Sutherland GR; Wranne B; Wigström L
    J Cardiovasc Magn Reson; 2004; 6(3):627-36. PubMed ID: 15347127
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous MRI tagging and through-plane velocity quantification: a three-dimensional myocardial motion tracking algorithm.
    Kuijer JP; Marcus JT; Götte MJ; van Rossum AC; Heethaar RM
    J Magn Reson Imaging; 1999 Mar; 9(3):409-19. PubMed ID: 10194711
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous measurement of blood and myocardial velocity in the rat heart by phase contrast MRI using sparse q-space sampling.
    Wise RG; Al-Shafei AI; Carpenter TA; Hall LD; Huang CL
    J Magn Reson Imaging; 2005 Nov; 22(5):614-27. PubMed ID: 16193471
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac magnetic resonance imaging for the evaluation of ventricular function.
    Sarwar A; Shapiro MD; Abbara S; Cury RC
    Semin Roentgenol; 2008 Jul; 43(3):183-92. PubMed ID: 18486680
    [No Abstract]   [Full Text] [Related]  

  • 13. Tag surface reconstruction and tracking of myocardial beads from SPAMM-MRI with parametric B-spline surfaces.
    Amini AA; Chen Y; Elayyadi M; Radeva P
    IEEE Trans Med Imaging; 2001 Feb; 20(2):94-103. PubMed ID: 11321594
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Extended harmonic phase tracking of myocardial motion: improved coverage of myocardium and its effect on strain results.
    Tecelão SR; Zwanenburg JJ; Kuijer JP; Marcus JT
    J Magn Reson Imaging; 2006 May; 23(5):682-90. PubMed ID: 16570245
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated 3D motion tracking using Gabor filter bank, robust point matching, and deformable models.
    Chen T; Wang X; Chung S; Metaxas D; Axel L
    IEEE Trans Med Imaging; 2010 Jan; 29(1):1-11. PubMed ID: 19369149
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A B-spline approach to phase unwrapping in tagged cardiac MRI for motion tracking.
    Chiang P; Cai Y; Mak KH; Zheng J
    Magn Reson Med; 2013 May; 69(5):1297-309. PubMed ID: 22692944
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.
    Sampath S; Derbyshire JA; Atalar E; Osman NF; Prince JL
    Magn Reson Med; 2003 Jul; 50(1):154-63. PubMed ID: 12815690
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional magnetic resonance myocardial motion tracking from a single image plane.
    Abd-Elmoniem KZ; Osman NF; Prince JL; Stuber M
    Magn Reson Med; 2007 Jul; 58(1):92-102. PubMed ID: 17659617
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Strain analyses of left ventricle wall with spatial modulation of magnetization based on two-dimensional method].
    Wang C; Inaba T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1037-40. PubMed ID: 17121349
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac material markers from tagged MR images.
    Kerwin WS; Prince JL
    Med Image Anal; 1998 Dec; 2(4):339-53. PubMed ID: 10072201
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.