BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 17278496)

  • 21. Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range.
    Butson MJ; Cheung T; Yu PK
    Appl Radiat Isot; 2006 Jan; 64(1):60-2. PubMed ID: 16105740
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Scanning orientation effects on Gafchromic EBT film dosimetry.
    Butson MJ; Cheung T; Yu PK
    Australas Phys Eng Sci Med; 2006 Sep; 29(3):281-4. PubMed ID: 17058592
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
    Paelinck L; De Neve W; De Wagter C
    Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.
    Rink A; Vitkin IA; Jaffray DA
    Med Phys; 2005 Aug; 32(8):2510-6. PubMed ID: 16193781
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accurate skin dose measurements using radiochromic film in clinical applications.
    Devic S; Seuntjens J; Abdel-Rahman W; Evans M; Olivares M; Podgorsak EB; Vuong T; Soares CG
    Med Phys; 2006 Apr; 33(4):1116-24. PubMed ID: 16696489
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.
    Lewis DF; Chan MF
    Med Phys; 2016 Feb; 43(2):643-9. PubMed ID: 26843228
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High sensitivity radiochromic film dose comparisons.
    Butson MJ; Yu PK; Cheung T; Metcalfe P
    Phys Med Biol; 2002 Nov; 47(22):N291-5. PubMed ID: 12476988
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dosimetric properties of Gafchromic EBT films in monoenergetic medical ion beams.
    Martisíková M; Jäkel O
    Phys Med Biol; 2010 Jul; 55(13):3741-51. PubMed ID: 20530848
    [TBL] [Abstract][Full Text] [Related]  

  • 30. XR type-R radiochromic film x-ray energy response.
    Butson MJ; Cheung T; Yu PK
    Phys Med Biol; 2005 Aug; 50(15):N195-9. PubMed ID: 16030377
    [TBL] [Abstract][Full Text] [Related]  

  • 31. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy.
    Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M
    Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?
    van Battum LJ; Hoffmans D; Piersma H; Heukelom S
    Med Phys; 2008 Feb; 35(2):704-16. PubMed ID: 18383692
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimization of the gafchromic EBT protocol for IMRT QA.
    Schneider F; Polednik M; Wolff D; Steil V; Delana A; Wenz F; Menegotti L
    Z Med Phys; 2009; 19(1):29-37. PubMed ID: 19459583
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of GafChromic EBT prototype B for external beam dose verification.
    Todorovic M; Fischer M; Cremers F; Thom E; Schmidt R
    Med Phys; 2006 May; 33(5):1321-8. PubMed ID: 16752567
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Energy dependence of EBT-1 radiochromic film response for photon (10 kvp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner.
    Richter C; Pawelke J; Karsch L; Woithe J
    Med Phys; 2009 Dec; 36(12):5506-14. PubMed ID: 20095263
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optical characterization of a radiochromic film by total reflectance and transmittance measurements.
    Fusi F; Mercatelli L; Marconi G; Cuttone G; Romano G
    Med Phys; 2004 Jul; 31(7):2147-54. PubMed ID: 15305469
    [TBL] [Abstract][Full Text] [Related]  

  • 37. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
    Saur S; Frengen J
    Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Modeling the dose dependence of the vis-absorption spectrum of EBT3 GafChromic™ films.
    Callens MB; Crijns W; Depuydt T; Haustermans K; Maes F; D'Agostino E; Wevers M; Pfeiffer H; Van Den Abeele K
    Med Phys; 2017 Jun; 44(6):2532-2543. PubMed ID: 28370086
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Role of water in the crystal structure of LiPCDA monomer and the radiotherapy dose response of EBT-3 film.
    Kaiyum R; Schruder CW; Mermut O; Rink A
    Med Phys; 2022 May; 49(5):3470-3480. PubMed ID: 35286716
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film.
    Sutherland JG; Rogers DW
    Med Phys; 2010 Mar; 37(3):1110-6. PubMed ID: 20384246
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.