These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
86 related articles for article (PubMed ID: 17278522)
1. Comment on: "Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence" [Med. Phys. 33, 2506-2518 (2006)]. MacDougall ND; Miquel ME; Keevil SF; Pitchford WG; Smith MA Med Phys; 2007 Jan; 34(1):366. PubMed ID: 17278522 [No Abstract] [Full Text] [Related]
2. Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence. Bayreder C; Georg D; Moser E; Berg A Med Phys; 2006 Jul; 33(7):2506-18. PubMed ID: 16898454 [TBL] [Abstract][Full Text] [Related]
3. Severe dose inaccuracies caused by an oxygen-antioxidant imbalance in normoxic polymer gel dosimeters. Sedaghat M; Bujold R; Lepage M Phys Med Biol; 2011 Feb; 56(3):601-25. PubMed ID: 21220843 [TBL] [Abstract][Full Text] [Related]
4. Investigating the potential of polymer gel dosimetry for interventional radiology: first results. Antoniou PE; Bousbouras P; Sandaltzopoulos R; Kaldoudi E Phys Med Biol; 2008 Apr; 53(8):N127-36. PubMed ID: 18364553 [TBL] [Abstract][Full Text] [Related]
5. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels. Khan M; Heilemann G; Kuess P; Georg D; Berg A Phys Med Biol; 2018 Mar; 63(6):06NT01. PubMed ID: 29528035 [TBL] [Abstract][Full Text] [Related]
6. A basic study of some normoxic polymer gel dosimeters. De Deene Y; Hurley C; Venning A; Vergote K; Mather M; Healy BJ; Baldock C Phys Med Biol; 2002 Oct; 47(19):3441-63. PubMed ID: 12408474 [TBL] [Abstract][Full Text] [Related]
7. Radiological properties of normoxic polymer gel dosimeters. Venning AJ; Nitschke KN; Keall PJ; Baldock C Med Phys; 2005 Apr; 32(4):1047-53. PubMed ID: 15895589 [TBL] [Abstract][Full Text] [Related]
8. Preliminary studies on the role and reactions of tetrakis(hydroxymethyl)phosphonium chloride in polyacrylamide gel dosimeters. Sedaghat M; Bujold R; Lepage M Phys Med Biol; 2012 Oct; 57(19):5981-94. PubMed ID: 22964826 [TBL] [Abstract][Full Text] [Related]
9. A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners. Hill B; Venning AJ; Baldock C Med Phys; 2005 Jun; 32(6):1589-97. PubMed ID: 16013718 [TBL] [Abstract][Full Text] [Related]
10. The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels. De Deene Y; Vergote K; Claeys C; De Wagter C Phys Med Biol; 2006 Feb; 51(3):653-73. PubMed ID: 16424587 [TBL] [Abstract][Full Text] [Related]
11. Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging. Venning AJ; Hill B; Brindha S; Healy BJ; Baldock C Phys Med Biol; 2005 Aug; 50(16):3875-88. PubMed ID: 16077233 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Sep; 58(18):6241-62. PubMed ID: 23965800 [TBL] [Abstract][Full Text] [Related]
13. On the validity of 3D polymer gel dosimetry: II. physico-chemical effects. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Jan; 58(1):43-61. PubMed ID: 23221322 [TBL] [Abstract][Full Text] [Related]
14. Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI. Haraldsson P; Karlsson A; Wieslander E; Gustavsson H; Bäck SA Phys Med Biol; 2006 Feb; 51(4):919-28. PubMed ID: 16467587 [TBL] [Abstract][Full Text] [Related]
15. Examination of THPC as an oxygen scavenger impacting VIC dosimeter thermal stability and comparison of NVP-containing polymer gel dosimeters. Jaszczak M; Kolesińska B; Wach R; Maras P; Dudek M; Kozicki M Phys Med Biol; 2019 Jan; 64(3):035019. PubMed ID: 30577036 [TBL] [Abstract][Full Text] [Related]
16. An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients. Baras P; Seimenis I; Sandilos P; Vlahos L; Bieganski T; Georgiou E; Pantelis E; Papagiannis P; Sakelliou L Med Phys; 2005 Nov; 32(11):3339-45. PubMed ID: 16370420 [TBL] [Abstract][Full Text] [Related]
17. The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy. Gear JI; Flux GD; Charles-Edwards E; Partridge M; Cook G; Ott RJ Phys Med Biol; 2006 Jul; 51(14):3503-16. PubMed ID: 16825745 [TBL] [Abstract][Full Text] [Related]
18. Investigation of tetrakis hydroxymethyl phosphonium chloride as an antioxidant for use in x-ray computed tomography polyacrylamide gel dosimetry. Jirasek A; Hilts M; Shaw C; Baxter P Phys Med Biol; 2006 Apr; 51(7):1891-906. PubMed ID: 16552112 [TBL] [Abstract][Full Text] [Related]
19. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy. Crescenti RA; Scheib SG; Schneider U; Gianolini S Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460 [TBL] [Abstract][Full Text] [Related]
20. Application of bi-nanoparticle on dose enhancement effect in two different polymer gel dosimeter using spectrophotometer. Sathiyaraj P; Jebaseelan Samuel EJ J Cancer Res Ther; 2018; 14(3):662-665. PubMed ID: 29893336 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]