These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

60 related articles for article (PubMed ID: 1728997)

  • 1. Will stress shielding limit the longevity of cemented femoral components of total hip replacement?
    Harris WH
    Clin Orthop Relat Res; 1992 Jan; (274):120-3. PubMed ID: 1728997
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing.
    O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH
    J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
    Behairy YM; Harris WH
    Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of material properties of femoral hip components on bone remodeling.
    Weinans H; Huiskes R; Grootenboer HJ
    J Orthop Res; 1992 Nov; 10(6):845-53. PubMed ID: 1403299
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials.
    Huiskes R; Weinans H; van Rietbergen B
    Clin Orthop Relat Res; 1992 Jan; (274):124-34. PubMed ID: 1728998
    [TBL] [Abstract][Full Text] [Related]  

  • 7. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters.
    Digas G
    Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femoral bone loss following hip replacement. A comparative study.
    Pritchett JW
    Clin Orthop Relat Res; 1995 May; (314):156-61. PubMed ID: 7634629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of cortical strain after cemented and press-fit proximal and distal femoral replacement.
    Hua J; Walker PS
    J Orthop Res; 1992 Sep; 10(5):739-44. PubMed ID: 1500986
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The various stress patterns of press-fit, ingrown, and cemented femoral stems.
    Huiskes R
    Clin Orthop Relat Res; 1990 Dec; (261):27-38. PubMed ID: 2245558
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Early aseptic loosening of the CF 30 femoral stem].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bone remodelling inside a cemented resurfaced femoral head.
    Gupta S; New AM; Taylor M
    Clin Biomech (Bristol); 2006 Jul; 21(6):594-602. PubMed ID: 16542761
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Metal-on-metal hip replacement using Metasul cups cemented into Muller reinforcement rings after a mean 5-year (3-8) follow-up: improvement of acetabular fixation by comparing with direct cementation to bone].
    Girard J; Herent S; Combes A; Pinoit Y; Soenen M; Laffargue P; Migaud H
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Jun; 94(4):346-53. PubMed ID: 18555860
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].
    Migaud H; Jardin C; Fontaine C; Pierchon F; d'Herbomez O; Duquennoy A
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(4):360-7. PubMed ID: 9452810
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
    Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
    Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Should monobloc cemented stems be systematically revised during revision total hip arthroplasty? A prospective evaluation].
    Grosjean G; Courpied JP; Moindreau M; Hunou N; Mathieu M; Hamadouche M
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Nov; 94(7):670-7. PubMed ID: 18984124
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 100 cemented versus 100 noncemented stems with comparison of 25 matched pairs.
    D'Lima DD; Oishi CS; Petersilge WJ; Colwell CW; Walker RH
    Clin Orthop Relat Res; 1998 Mar; (348):140-8. PubMed ID: 9553546
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Otto Aufranc Award. Skeletal response to well fixed femoral components inserted with and without cement.
    Maloney WJ; Sychterz C; Bragdon C; McGovern T; Jasty M; Engh CA; Harris WH
    Clin Orthop Relat Res; 1996 Dec; (333):15-26. PubMed ID: 8981879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.