These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 17290919)

  • 1. [Experimental study of the hydrodynamics of polyurethane tricuspid heart valves].
    Sister VG; Iurechko VN
    Med Tekh; 2006; (6):8-14. PubMed ID: 17290919
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Experimental study of hydrodynamics of artificial heart valves].
    Vil'danov LM; Etonov MP; Iurechko VN
    Med Tekh; 1998; (2):11-8. PubMed ID: 9611743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Medinzh artificial cardiac valves].
    Iurechko VN; Sister VG
    Med Tekh; 2007; (3):13-23. PubMed ID: 17600929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Study of hydrodynamic characteristics of artificial heart valves by photochromic imaging].
    Vil'danov LM; Etonov MP; Iurechko VN
    Med Tekh; 1998; (1):10-20. PubMed ID: 9560812
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new design for polyurethane heart valves.
    Butterfield M; Wheatley DJ; Williams DF; Fisher J
    J Heart Valve Dis; 2001 Jan; 10(1):105-10. PubMed ID: 11206756
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro function and durability of a polyurethane heart valve: material considerations.
    Bernacca GM; Mackay TG; Wheatley DJ
    J Heart Valve Dis; 1996 Sep; 5(5):538-42. PubMed ID: 8894995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cholesterol-modified polyurethane valve cusps demonstrate blood outgrowth endothelial cell adhesion post-seeding in vitro and in vivo.
    Stachelek SJ; Alferiev I; Connolly JM; Sacks M; Hebbel RP; Bianco R; Levy RJ
    Ann Thorac Surg; 2006 Jan; 81(1):47-55. PubMed ID: 16368333
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of prosthetic valve hydrodynamic function: objective testing using statistical multilevel modeling.
    Bernacca GM; McColl JH; Wheatley DJ
    J Heart Valve Dis; 2004 May; 13(3):467-77. PubMed ID: 15222295
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Polyurethane heart valves: past, present and future.
    Kütting M; Roggenkamp J; Urban U; Schmitz-Rode T; Steinseifer U
    Expert Rev Med Devices; 2011 Mar; 8(2):227-33. PubMed ID: 21381912
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical models for the simulation of flexible artificial heart valves: part I--computational methods.
    Fenlon AJ; David T
    Comput Methods Biomech Biomed Engin; 2001; 4(4):323-39. PubMed ID: 11328643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevention of polyurethane valve cusp calcification with covalently attached bisphosphonate diethylamino moieties.
    Alferiev I; Stachelek SJ; Lu Z; Fu AL; Sellaro TL; Connolly JM; Bianco RW; Sacks MS; Levy RJ
    J Biomed Mater Res A; 2003 Aug; 66(2):385-95. PubMed ID: 12889009
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A detailed fluid mechanics study of tilting disk mechanical heart valve closure and the implications to blood damage.
    Manning KB; Herbertson LH; Fontaine AA; Deutsch S
    J Biomech Eng; 2008 Aug; 130(4):041001. PubMed ID: 18601443
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cavitation behavior observed in three monoleaflet mechanical heart valves under accelerated testing conditions.
    Lo CW; Liu JS; Li CP; Lu PC; Hwang NH
    ASAIO J; 2008; 54(2):163-71. PubMed ID: 18356649
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Experimental study of artificial disk heart valves].
    Etonov MP; Iurechko VN; Iurechko RV; Radkevich FA
    Med Tekh; 1999; (3):32-7. PubMed ID: 10475790
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An experimentally derived stress resultant shell model for heart valve dynamic simulations.
    Kim H; Chandran KB; Sacks MS; Lu J
    Ann Biomed Eng; 2007 Jan; 35(1):30-44. PubMed ID: 17089074
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Vena cava as autologous tissue for pulmonary valve substitute.
    Scharfschwerdt M; Sievers HH; von Heinz M; Schmidtke C
    Interact Cardiovasc Thorac Surg; 2008 Dec; 7(6):973-6. PubMed ID: 18718954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A comment on optimal shaped prosthesis for tricuspid valve using an experimental model].
    Fukushima Y; Kitamura N; Adachi T; Miki T; Yamaguchi A; Otaki M; Minoji T; Tamura H
    Nihon Kyobu Geka Gakkai Zasshi; 1989 Jun; 37(6):1174-8. PubMed ID: 2809291
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Numerical analysis on the hemodynamics and leaflet dynamics in a bileaflet mechanical heart valve using a fluid-structure interaction method.
    Choi CR; Kim CN
    ASAIO J; 2009; 55(5):428-37. PubMed ID: 19730001
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro determination of the curvatures and bending strains acting on the leaflets of polyurethane trileaflet heart valves during leaflet motion.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1995; 209(4):243-53. PubMed ID: 8907218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.