These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. [An experience of using the DRK-1 dosimeter with conduit ionizing chamber for monitoring the parameters of X-ray diagnostic equipment]. Voronin KV; Okhrimenko SE Med Tekh; 2003; (5):35-7. PubMed ID: 14603849 [TBL] [Abstract][Full Text] [Related]
4. [A portable miniature IMD-01 X-ray dosimeter for monitoring the dose power in radiodiagnosis]. Vladimirov LV; Kozlov AA Med Tekh; 2002; (5):24-7. PubMed ID: 12512279 [TBL] [Abstract][Full Text] [Related]
5. [Computer-assisted combined management of physical radiation protection and quality control of X-ray diagnostic equipment]. Traino AC; Tana L; Tosetti M; Lazzeri M Radiol Med; 1994 May; 87(5):694-8. PubMed ID: 8008903 [TBL] [Abstract][Full Text] [Related]
7. [Development of a system controlling x-ray diagnostic devices]. Zhutiaev SG; Mishkinis BIa; Chikirdin EG Med Tekh; 1992; (4):3-7. PubMed ID: 1435143 [TBL] [Abstract][Full Text] [Related]
8. [Checking of the automated collimation system of the X-ray beams in diagnostic equipment]. Voronin KV; Okhrimenko SE Med Tekh; 2004; (6):38-9. PubMed ID: 15656415 [No Abstract] [Full Text] [Related]
9. An evaluation of semiconductor and ionization chamber detectors for diagnostic x-ray dosimetry measurements. Martin CJ Phys Med Biol; 2007 Aug; 52(15):4465-80. PubMed ID: 17634644 [TBL] [Abstract][Full Text] [Related]
10. [Controlling of the high-voltage generator in a direct radiography system]. Shen JX; Xu P; Zhou HQ; Feng HQ Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Mar; 30(2):111-3. PubMed ID: 16830803 [TBL] [Abstract][Full Text] [Related]
11. [On systematization of engineering tests of X-ray diagnostic equipment under conditions of treatment-and-prophylaxis institutions]. Kruchinin SA; Rezvykh SV; Shengeliia NA Med Tekh; 2005; (5):22-4. PubMed ID: 16285242 [TBL] [Abstract][Full Text] [Related]
12. [Contemporary requirements for the radiation safety of x-ray diagnostic rooms]. Blinov NN; Kozlovskiĭ EB Med Tekh; 2008; (5):23-5. PubMed ID: 19048862 [No Abstract] [Full Text] [Related]
14. [Hygienic requirement for calculation the protection, radiation control and control of the exploitation parameters for the X-ray equipment]. Ermolina EP; Pertsov VA Med Tekh; 2003; (5):9-11. PubMed ID: 14603842 [TBL] [Abstract][Full Text] [Related]
15. [The ID-03 X-ray dosimeter for monitoring the radiation parameters of X-ray equipment in roentgenography]. Vladimirov LV; Kozlov AA Med Tekh; 2002; (5):22-4. PubMed ID: 12512278 [TBL] [Abstract][Full Text] [Related]
17. [Use of diagnostic dosimeters to evaluate x-ray diagnostic study methods as well as the training level of the researchers]. Gursky S; Schulz HG; König W; Menzel B; Wässer R Radiol Diagn (Berl); 1980; 21(3):403-8. PubMed ID: 7455058 [No Abstract] [Full Text] [Related]
18. Tunable monochromatic X rays: a new paradigm in medicine. Carroll FE AJR Am J Roentgenol; 2002 Sep; 179(3):583-90. PubMed ID: 12185024 [No Abstract] [Full Text] [Related]
19. [Measured and calculated doses of transmitted and reflected radiation in the radiation energy range of x-ray diagnostic equipment]. Gurzhiev AN; Gurzhiev SN; Korablev VM; Kostritskiĭ AV Med Tekh; 2008; (5):19-22. PubMed ID: 19051419 [No Abstract] [Full Text] [Related]
20. [Hardware-software system for monitoring parameters and characteristics of X-ray computer tomographs under operation conditions]. Blinov NN; Zelikman MI; Kruchinin SA Med Tekh; 2007; (5):28-31. PubMed ID: 18030772 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]