These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 17295066)

  • 1. Design considerations for an implantable, muscle powered piezoelectric system for generating electrical power.
    Lewandowski BE; Kilgore KL; Gustafson KJ
    Ann Biomed Eng; 2007 Apr; 35(4):631-41. PubMed ID: 17295066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo demonstration of a self-sustaining, implantable, stimulated-muscle-powered piezoelectric generator prototype.
    Lewandowski BE; Kilgore KL; Gustafson KJ
    Ann Biomed Eng; 2009 Nov; 37(11):2390-401. PubMed ID: 19657742
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new skeletal muscle linear-pull energy convertor as a power source for prosthetic circulatory support devices [corrected].
    Farrar DJ; Hill JD
    J Heart Lung Transplant; 1992; 11(5):S341-50. PubMed ID: 1420227
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implantable power generation system utilizing muscle contractions excited by electrical stimulation.
    Sahara G; Hijikata W; Tomioka K; Shinshi T
    Proc Inst Mech Eng H; 2016 Jun; 230(6):569-78. PubMed ID: 27006422
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Models of metabolic utilization predict limiting conditions for sustained power from conditioned skeletal muscle.
    Gustafson KJ; Marinache SM; Egrie GD; Reichenbach SH
    Ann Biomed Eng; 2006 May; 34(5):790-8. PubMed ID: 16598656
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo performance of a muscle-powered drive system for implantable blood pumps.
    Trumble DR; Melvin DB; Dean DA; Magovern JA
    ASAIO J; 2008; 54(3):227-32. PubMed ID: 18496270
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Frequency-dependent power output and skeletal muscle design.
    Medler S; Hulme K
    Comp Biochem Physiol A Mol Integr Physiol; 2009 Mar; 152(3):407-17. PubMed ID: 19101645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design optimization of contactless generator for implantable energy harvesting system utilizing electrically-stimulated muscle.
    Mochida T; Hijikata W
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():358-363. PubMed ID: 31945915
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A deterministic mechanism producing the loose coupling phenomenon observed in an actomyosin system.
    Masuda T
    Biosystems; 2009 Feb; 95(2):104-13. PubMed ID: 18793694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a contactless energy harvesting system driven by contraction of skeletal muscle for implantable medical devices.
    Mochida T; Hijikata W
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():4648-4652. PubMed ID: 30441387
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design study of piezoelectric energy-harvesting devices for generation of higher electrical power using a coupled piezoelectric-circuit finite element method.
    Zhu M; Worthington E; Tiwari A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010; 57(2):427-37. PubMed ID: 20178909
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies.
    Liacouras PC; Wayne JS
    J Biomech Eng; 2007 Dec; 129(6):811-17. PubMed ID: 18067384
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo studies of an implantable energy convertor for skeletal muscle powered cardiac assist.
    Reichenbach SH; Farrar DJ; Diao E; Hill JD
    ASAIO J; 1997; 43(5):M668-72. PubMed ID: 9360130
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Power harvesting using PZT ceramics embedded in orthopedic implants.
    Chen H; Liu M; Jia C; Wang Z
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Sep; 56(9):2010-4. PubMed ID: 19812004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Power generation from four skeletal muscle configurations. Design implications for a muscle powered cardiac assist device.
    Badhwar V; Badhwar RK; Oh JH; Chiu RC
    ASAIO J; 1997; 43(5):M651-7. PubMed ID: 9360126
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Piezoelectric diaphragm for vibration energy harvesting.
    Minazara E; Vasic D; Costa F; Poulin G
    Ultrasonics; 2006 Dec; 44 Suppl 1():e699-703. PubMed ID: 16814837
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of pedaling rate on muscle mechanical energy in low power recumbent pedaling using forward dynamic simulations.
    Hakansson NA; Hull ML
    IEEE Trans Neural Syst Rehabil Eng; 2007 Dec; 15(4):509-16. PubMed ID: 18198708
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microelectronics mounted on a piezoelectric transducer: method, simulations, and measurements.
    Johansson J; Delsing J
    Ultrasonics; 2006 Jan; 44(1):1-11. PubMed ID: 16107274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sustained skeletal muscle power for cardiac assist devices: implications of metabolic constraints.
    Reichenbach SH; Egrie GD; Marinache SM; Gustafson KJ; Farrar DJ; Hill JD
    ASAIO J; 2001; 47(5):541-7. PubMed ID: 11575834
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A totally implantable electrical heart.
    Jufer M
    J Heart Transplant; 1985; 4(5):496-8. PubMed ID: 3843614
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.