155 related articles for article (PubMed ID: 17300739)
1. Immobilized molecular beacons: a new strategy using UV-activated poly(methyl methacrylate) surfaces to provide large fluorescence sensitivities for reporting on molecular association events.
Situma C; Moehring AJ; Noor MA; Soper SA
Anal Biochem; 2007 Apr; 363(1):35-45. PubMed ID: 17300739
[TBL] [Abstract][Full Text] [Related]
2. Fabrication of DNA microarrays onto poly(methyl methacrylate) with ultraviolet patterning and microfluidics for the detection of low-abundant point mutations.
Situma C; Wang Y; Hupert M; Barany F; McCarley RL; Soper SA
Anal Biochem; 2005 May; 340(1):123-35. PubMed ID: 15802138
[TBL] [Abstract][Full Text] [Related]
3. Functionalization of poly(methyl methacrylate) (PMMA) as a substrate for DNA microarrays.
Fixe F; Dufva M; Telleman P; Christensen CB
Nucleic Acids Res; 2004 Jan; 32(1):e9. PubMed ID: 14718554
[TBL] [Abstract][Full Text] [Related]
4. Fabrication of DNA microarrays onto polymer substrates using UV modification protocols with integration into microfluidic platforms for the sensing of low-abundant DNA point mutations.
Soper SA; Hashimoto M; Situma C; Murphy MC; McCarley RL; Cheng YW; Barany F
Methods; 2005 Sep; 37(1):103-13. PubMed ID: 16199178
[TBL] [Abstract][Full Text] [Related]
5. A new optical platform for biosensing based on fluorescence anisotropy.
Baldini F; Carloni A; Giannetti A; Porro G; Trono C
Anal Bioanal Chem; 2008 Jul; 391(5):1837-44. PubMed ID: 18274733
[TBL] [Abstract][Full Text] [Related]
6. Photochemically patterned poly(methyl methacrylate) surfaces used in the fabrication of microanalytical devices.
Wei S; Vaidya B; Patel AB; Soper SA; McCarley RL
J Phys Chem B; 2005 Sep; 109(35):16988-96. PubMed ID: 16853163
[TBL] [Abstract][Full Text] [Related]
7. Immobilization of DNAzyme catalytic beacons on PMMA for Pb2+ detection.
Dalavoy TS; Wernette DP; Gong M; Sweedler JV; Lu Y; Flachsbart BR; Shannon MA; Bohn PW; Cropek DM
Lab Chip; 2008 May; 8(5):786-93. PubMed ID: 18432350
[TBL] [Abstract][Full Text] [Related]
8. Air Plasma-Enhanced Covalent Functionalization of Poly(methyl methacrylate): High-Throughput Protein Immobilization for Miniaturized Bioassays.
Sathish S; Ishizu N; Shen AQ
ACS Appl Mater Interfaces; 2019 Dec; 11(49):46350-46360. PubMed ID: 31722179
[TBL] [Abstract][Full Text] [Related]
9. [Viability of murine 3T3 fibroblasts on the poly(methyl methacrylate) surface modified by constant UV irradiation].
Chaberska H; Kaczmarek H; Bazylak G
Polim Med; 2007; 37(3):13-9. PubMed ID: 18251201
[TBL] [Abstract][Full Text] [Related]
10. Ligase detection reaction/hybridization assays using three-dimensional microfluidic networks for the detection of low-abundant DNA point mutations.
Hashimoto M; Hupert ML; Murphy MC; Soper SA; Cheng YW; Barany F
Anal Chem; 2005 May; 77(10):3243-55. PubMed ID: 15889915
[TBL] [Abstract][Full Text] [Related]
11. PMMA biosensor for nucleic acids with integrated mixer and electrochemical detection.
Nugen SR; Asiello PJ; Connelly JT; Baeumner AJ
Biosens Bioelectron; 2009 Apr; 24(8):2428-33. PubMed ID: 19168346
[TBL] [Abstract][Full Text] [Related]
12. One-step immobilization of aminated and thiolated DNA onto poly(methylmethacrylate) (PMMA) substrates.
Fixe F; Dufva M; Telleman P; Christensen CB
Lab Chip; 2004 Jun; 4(3):191-5. PubMed ID: 15159777
[TBL] [Abstract][Full Text] [Related]
13. Surface modification of poly(methyl methacrylate) used in the fabrication of microanalytical devices.
Henry AC; Tutt TJ; Galloway M; Davidson YY; McWhorter CS; Soper SA; McCarley RL
Anal Chem; 2000 Nov; 72(21):5331-7. PubMed ID: 11080884
[TBL] [Abstract][Full Text] [Related]
14. Microfluidic DNA microarrays in PMMA chips: streamlined fabrication via simultaneous DNA immobilization and bonding activation by brief UV exposure.
Sabourin D; Petersen J; Snakenborg D; Brivio M; Gudnadson H; Wolff A; Dufva M
Biomed Microdevices; 2010 Aug; 12(4):673-81. PubMed ID: 20336488
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of different nonspecific binding blocking agents deposited inside poly(methyl methacrylate) microfluidic flow-cells.
Le NC; Gubala V; Gandhiraman RP; Daniels S; Williams DE
Langmuir; 2011 Jul; 27(14):9043-51. PubMed ID: 21648475
[TBL] [Abstract][Full Text] [Related]
16. A gene necessary for normal male courtship, yellow, acts downstream of fruitless in the Drosophila melanogaster larval brain.
Drapeau MD; Radovic A; Wittkopp PJ; Long AD
J Neurobiol; 2003 Apr; 55(1):53-72. PubMed ID: 12605459
[TBL] [Abstract][Full Text] [Related]
17. Protein immobilization on the surface of polydimethylsiloxane and polymethyl methacrylate microfluidic devices.
Khnouf R; Karasneh D; Albiss BA
Electrophoresis; 2016 Feb; 37(3):529-35. PubMed ID: 26534833
[TBL] [Abstract][Full Text] [Related]
18. Plasticizer-assisted bonding of poly(methyl methacrylate) microfluidic chips at low temperature.
Duan H; Zhang L; Chen G
J Chromatogr A; 2010 Jan; 1217(1):160-6. PubMed ID: 19945714
[TBL] [Abstract][Full Text] [Related]
19. Molecular beacons for DNA biosensors with micrometer to submicrometer dimensions.
Liu X; Farmerie W; Schuster S; Tan W
Anal Biochem; 2000 Jul; 283(1):56-63. PubMed ID: 10929808
[TBL] [Abstract][Full Text] [Related]
20. Surface modification of poly(methyl methacrylate) for improved adsorption of wall coating polymers for microchip electrophoresis.
Shah JJ; Geist J; Locascio LE; Gaitan M; Rao MV; Vreeland WN
Electrophoresis; 2006 Oct; 27(19):3788-96. PubMed ID: 16960835
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]