BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 17303619)

  • 1. Calibration of the spring constant of AFM cantilever.
    Jing GY; Ma J; Yu DP
    J Electron Microsc (Tokyo); 2007 Jan; 56(1):21-5. PubMed ID: 17303619
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers.
    Yeh MK; Tai NH; Chen BY
    Ultramicroscopy; 2008 Sep; 108(10):1025-9. PubMed ID: 18547729
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spring constant calibration of atomic force microscopy cantilevers with a piezosensor transfer standard.
    Langlois ED; Shaw GA; Kramar JA; Pratt JR; Hurley DC
    Rev Sci Instrum; 2007 Sep; 78(9):093705. PubMed ID: 17902953
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever.
    Yeh MK; Tai NH; Chen BY
    Rev Sci Instrum; 2009 Apr; 80(4):043705. PubMed ID: 19405664
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of the spring constant of atomic force microscopy cantilevers by finite element method.
    Chen BY; Yeh MK; Tai NH
    Anal Chem; 2007 Feb; 79(4):1333-8. PubMed ID: 17297931
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array.
    Gates RS; Reitsma MG
    Rev Sci Instrum; 2007 Aug; 78(8):086101. PubMed ID: 17764361
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid.
    Pettersson T; Nordgren N; Rutland MW; Feiler A
    Rev Sci Instrum; 2007 Sep; 78(9):093702. PubMed ID: 17902950
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cantilever spring constant calibration using laser Doppler vibrometry.
    Ohler B
    Rev Sci Instrum; 2007 Jun; 78(6):063701. PubMed ID: 17614610
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interlaboratory round robin on cantilever calibration for AFM force spectroscopy.
    te Riet J; Katan AJ; Rankl C; Stahl SW; van Buul AM; Phang IY; Gomez-Casado A; Schön P; Gerritsen JW; Cambi A; Rowan AE; Vancso GJ; Jonkheijm P; Huskens J; Oosterkamp TH; Gaub H; Hinterdorfer P; Figdor CG; Speller S
    Ultramicroscopy; 2011 Dec; 111(12):1659-69. PubMed ID: 22094372
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor.
    Xie H; Vitard J; Haliyo S; Régnier S; Boukallel M
    Rev Sci Instrum; 2008 Mar; 79(3):033708. PubMed ID: 18377016
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration of higher eigenmode spring constants of atomic force microscope cantilevers.
    Lozano JR; Kiracofe D; Melcher J; Garcia R; Raman A
    Nanotechnology; 2010 Nov; 21(46):465502. PubMed ID: 20972309
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: a kinetostatic method.
    Tseytlin YM
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):025102. PubMed ID: 18315324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method for atomic force microscopy cantilever stiffness calibration under heavy fluid loading.
    Kennedy SJ; Cole DG; Clark RL
    Rev Sci Instrum; 2009 Dec; 80(12):125103. PubMed ID: 20059166
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calibration of AFM cantilever spring constants.
    Gibson CT; Weeks BL; Abell C; Rayment T; Myhra S
    Ultramicroscopy; 2003; 97(1-4):113-8. PubMed ID: 12801663
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers.
    Golovko DS; Haschke T; Wiechert W; Bonaccurso E
    Rev Sci Instrum; 2007 Apr; 78(4):043705. PubMed ID: 17477668
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Error in dynamic spring constant calibration of atomic force microscope probes due to nonuniform cantilevers.
    Frentrup H; Allen MS
    Nanotechnology; 2011 Jul; 22(29):295703. PubMed ID: 21673383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calibration of AFM cantilever stiffness: a microfabricated array of reflective springs.
    Cumpson PJ; Zhdan P; Hedley J
    Ultramicroscopy; 2004 Aug; 100(3-4):241-51. PubMed ID: 15231316
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope.
    Rawlings C; Durkan C
    Nanotechnology; 2012 Dec; 23(48):485708. PubMed ID: 23137943
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers.
    Sader JE; Friend JR
    Rev Sci Instrum; 2015 May; 86(5):056106. PubMed ID: 26026567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atomic force microscope cantilever calibration using a focused ion beam.
    Slattery AD; Quinton JS; Gibson CT
    Nanotechnology; 2012 Jul; 23(28):285704. PubMed ID: 22728463
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.