BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 17312204)

  • 1. The hemostatic history of a 15-month-old child implanted with a Berlin heart left ventricular assist device.
    Steenwyk BL; Kirklin JK; Gurley WQ; Nielsen VG
    Anesth Analg; 2007 Mar; 104(3):538-40. PubMed ID: 17312204
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemostasis management in pediatric mechanical circulatory support.
    Seibel K; Berdat P; Boillat C; Wagner B; Zachariou Z; Kessler U
    Ann Thorac Surg; 2008 Apr; 85(4):1453-6. PubMed ID: 18355556
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Subcutaneous low molecular weight heparin for management of anticoagulation in infants on excor ventricular assist device.
    Ghez O; Liesner R; Karimova A; Ng C; Goldman A; van Doorn C
    ASAIO J; 2006; 52(6):705-7. PubMed ID: 17117062
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Successful bridge to transplant using the Berlin Heart left ventricular assist device in a 3-month-old infant.
    Dunnington GH; Sleasman J; Alkhaldi A; Pelletier MP; Reitz BA; Robbins RC
    Ann Thorac Surg; 2006 Mar; 81(3):1116-8. PubMed ID: 16488739
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical cardiac support in the young with the Berlin Heart EXCOR pulsatile ventricular assist device: 15 years' experience.
    Hetzer R; Alexi-Meskishvili V; Weng Y; Hübler M; Potapov E; Drews T; Hennig E; Kaufmann F; Stiller B
    Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu; 2006; ():99-108. PubMed ID: 16638554
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preliminary single center North American experience with the Berlin Heart pediatric EXCOR device.
    Rockett SR; Bryant JC; Morrow WR; Frazier EA; Fiser WP; McKamie WA; Johnson CE; Chipman CW; Imamura M; Jaquiss RD
    ASAIO J; 2008; 54(5):479-82. PubMed ID: 18812737
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ventricular assist device application with the intermediate use of a membrane oxygenator as a bridge to pediatric heart transplantation.
    Garcia-Guereta L; Cabo J; de la Oliva P; Villar MA; Bronte LD; Goldman L; Hübler M
    J Heart Lung Transplant; 2009 Jul; 28(7):740-2. PubMed ID: 19560705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of pediatric Berlin Heart EXCOR biventricular device as a bridge to retransplantation in a 10-month-old infant with acute graft failure after cardiac transplantation.
    Krokstrom AK; Higgins T; Johansson S; Jögi P
    ASAIO J; 2009; 55(5):525-6. PubMed ID: 19730011
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.
    John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L
    Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
    Zimpfer D; Zrunek P; Roethy W; Czerny M; Schima H; Huber L; Grimm M; Rajek A; Wolner E; Wieselthaler G
    J Thorac Cardiovasc Surg; 2007 Mar; 133(3):689-95. PubMed ID: 17320566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prognostic value of left ventricular apical tissue removed for HeartMate II left ventricular assist device placement.
    Soderlund KA; Chivukula RR; Russell SD; Conte JV; Mudd JO; Halushka MK
    Cardiovasc Pathol; 2009; 18(4):217-22. PubMed ID: 18706833
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Whole blood hypercoagulability despite anticoagulation during mechanical cardiac assist.
    Niemi TT; Kukkonen SI; Hämmäinen PT; Suojaranta-Ylinen RT; Sipponen JT
    Perfusion; 2008 Mar; 23(2):107-10. PubMed ID: 18840579
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumatic paracorporeal ventricular assist device in infants and children: initial Stanford experience.
    Malaisrie SC; Pelletier MP; Yun JJ; Sharma K; Timek TA; Rosenthal DN; Wright GE; Robbins RC; Reitz BA
    J Heart Lung Transplant; 2008 Feb; 27(2):173-7. PubMed ID: 18267223
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Connecting the Centrimag Levitronix pump to Berlin Heart Excor cannulae; a new approach to bridge to bridge.
    Maat AP; van Thiel RJ; Dalinghaus M; Bogers AJ
    J Heart Lung Transplant; 2008 Jan; 27(1):112-5. PubMed ID: 18187096
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Management of deep wound complications with vacuum-assisted therapy after Berlin Heart EXCOR ventricular assist device placement in the pediatric population.
    Kouretas PC; Burch PT; Kaza AK; Lambert LM; Witte MK; Everitt MD; Siddiqi FA
    Artif Organs; 2009 Nov; 33(11):922-5. PubMed ID: 19874282
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ventricular assist device as a bridge to transplant, and extracorporeal membrane oxygenation for primary graft failure in a child with hemophilia A.
    Frías MÁ; Jaraba S; Ibarra I; Arroyo MJ; Velasco MJ; Ulloa E; Velasco F; Pérez-Navero JL
    Pediatr Crit Care Med; 2011 Nov; 12(6):e432-5. PubMed ID: 21926657
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiac extracorporeal life support: state of the art in 2007.
    Cooper DS; Jacobs JP; Moore L; Stock A; Gaynor JW; Chancy T; Parpard M; Griffin DA; Owens T; Checchia PA; Thiagarajan RR; Spray TL; Ravishankar C
    Cardiol Young; 2007 Sep; 17 Suppl 2():104-15. PubMed ID: 18039404
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of pediatric patients after implantation of the Berlin Heart EXCOR ventricular assist device.
    Stiller B; Lemmer J; Schubert S; Ewert P; Schulze-Neick I; Hübler M; Redlin M; Berger F; Hetzer R
    ASAIO J; 2006; 52(5):497-500. PubMed ID: 16966844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo preclinical anticoagulation regimens after implantation of ventricular assist devices.
    Saeed D; Fukamachi K
    Artif Organs; 2009 Jul; 33(7):491-503. PubMed ID: 19566726
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bridge to transplant using the MicroMed DeBakey ventricular assist device in a child with idiopathic dilated cardiomyopathy.
    Padalino MA; Ohye RG; Chang AC; Gajarski RJ; Bove EL; Devaney EJ
    Ann Thorac Surg; 2006 Mar; 81(3):1118-21. PubMed ID: 16488740
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.