BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

701 related articles for article (PubMed ID: 17314040)

  • 1. Fabrication of sucrose biosensor based on single mode planar optical waveguide using co-immobilized plant invertase and GOD.
    Bagal DS; Vijayan A; Aiyer RC; Karekar RN; Karve MS
    Biosens Bioelectron; 2007 Jun; 22(12):3072-9. PubMed ID: 17314040
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Invertase inhibition based electrochemical sensor for the detection of heavy metal ions in aqueous system: Application of ultra-microelectrode to enhance sucrose biosensor's sensitivity.
    Bagal-Kestwal D; Karve MS; Kakade B; Pillai VK
    Biosens Bioelectron; 2008 Dec; 24(4):657-64. PubMed ID: 18667298
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.
    Salimi A; Compton RG; Hallaj R
    Anal Biochem; 2004 Oct; 333(1):49-56. PubMed ID: 15351279
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment.
    Shan D; He Y; Wang S; Xue H; Zheng H
    Anal Biochem; 2006 Sep; 356(2):215-21. PubMed ID: 16842730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of electrochemical biosensor based on tyrosinase immobilized in composite biopolymeric film.
    Tembe S; Karve M; Inamdar S; Haram S; Melo J; D'Souza SF
    Anal Biochem; 2006 Feb; 349(1):72-7. PubMed ID: 16360108
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of amperometric biosensor for glucose based on a novel attractive enzyme immobilization matrix: calcium carbonate nanoparticles.
    Shan D; Zhu M; Xue H; Cosnier S
    Biosens Bioelectron; 2007 Mar; 22(8):1612-7. PubMed ID: 16920350
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Study on multiple-enzyme electrode for sucrose determination.
    Hu W; Zhang X; Zhang X; Hu S
    Chin J Biotechnol; 1991; 7(4):293-300. PubMed ID: 1824242
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Glucose biosensor based on the room-temperature phosphorescence of TiO2/SiO2 nanocomposite.
    Li Y; Liu X; Yuan H; Xiao D
    Biosens Bioelectron; 2009 Aug; 24(12):3706-10. PubMed ID: 19541471
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bienzymatic glucose biosensor based on co-immobilization of peroxidase and glucose oxidase on a carbon nanotubes electrode.
    Zhu L; Yang R; Zhai J; Tian C
    Biosens Bioelectron; 2007 Nov; 23(4):528-35. PubMed ID: 17764922
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Palladium hexacyanoferrate hydrogel as a novel and simple enzyme immobilization matrix for amperometric biosensors.
    Iveković D; Milardović S; Grabarić BS
    Biosens Bioelectron; 2004 Nov; 20(4):872-8. PubMed ID: 15522604
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Glucose biosensor based on electrodeposition of platinum nanoparticles onto carbon nanotubes and immobilizing enzyme with chitosan-SiO(2) sol-gel.
    Zou Y; Xiang C; Sun LX; Xu F
    Biosens Bioelectron; 2008 Feb; 23(7):1010-6. PubMed ID: 18054479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode.
    Li J; Lin X
    Biosens Bioelectron; 2007 Jun; 22(12):2898-905. PubMed ID: 17215117
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of glucose amperometric biosensor based on a novel attractive enzyme immobilization matrix: amino derivative of thiacalix[4]arene.
    Chen M; Zhang W; Jiang R; Diao G
    Anal Chim Acta; 2011 Feb; 687(2):177-83. PubMed ID: 21277420
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes.
    Kang X; Mai Z; Zou X; Cai P; Mo J
    Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of polymaleimidostyrene as a convenient immobilization reagent of enzyme in biosensor.
    Uchiyama S; Tomita R; Sekioka N; Imaizumi E; Hamana H; Hagiwara T
    Bioelectrochemistry; 2006 May; 68(2):119-25. PubMed ID: 16039167
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chemiluminescence flow biosensor for glucose based on gold nanoparticle-enhanced activities of glucose oxidase and horseradish peroxidase.
    Lan D; Li B; Zhang Z
    Biosens Bioelectron; 2008 Dec; 24(4):940-4. PubMed ID: 18783937
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical biosensor based on hollow integrated waveguides.
    Cadarso VJ; Fernández-Sánchez C; Llobera A; Darder M; Domínguez C
    Anal Chem; 2008 May; 80(9):3498-501. PubMed ID: 18393473
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Immobilization of glucose oxidase on electrodeposited nickel oxide nanoparticles: direct electron transfer and electrocatalytic activity.
    Salimi A; Sharifi E; Noorbakhsh A; Soltanian S
    Biosens Bioelectron; 2007 Jun; 22(12):3146-53. PubMed ID: 17368016
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fabrication of a miniature CMOS-based optical biosensor.
    Ho WJ; Chen JS; Ker MD; Wu TK; Wu CY; Yang YS; Li YK; Yuan CJ
    Biosens Bioelectron; 2007 Jun; 22(12):3008-13. PubMed ID: 17320371
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel glucose biosensor based on the immobilization of glucose oxidase onto gold nanoparticles-modified Pb nanowires.
    Wang H; Wang X; Zhang X; Qin X; Zhao Z; Miao Z; Huang N; Chen Q
    Biosens Bioelectron; 2009 Sep; 25(1):142-6. PubMed ID: 19595586
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 36.