These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
246 related articles for article (PubMed ID: 17322429)
1. Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study. Daniel J; Ziaee H; Pradhan C; Pynsent PB; McMinn DJ J Bone Joint Surg Br; 2007 Feb; 89(2):169-73. PubMed ID: 17322429 [TBL] [Abstract][Full Text] [Related]
2. Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. Daniel J; Ziaee H; Pradhan C; McMinn DJ J Bone Joint Surg Br; 2009 Feb; 91(2):176-9. PubMed ID: 19190049 [TBL] [Abstract][Full Text] [Related]
3. Systemic metal exposure in large- and small-diameter metal-on-metal total hip replacements. Daniel J; Ziaee H; Pradhan C; McMinn DJ Orthopedics; 2008 Dec; 31(12 Suppl 2):. PubMed ID: 19298017 [TBL] [Abstract][Full Text] [Related]
4. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698 [TBL] [Abstract][Full Text] [Related]
5. Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study. Ziaee H; Daniel J; Datta AK; Blunt S; McMinn DJ J Bone Joint Surg Br; 2007 Mar; 89(3):301-5. PubMed ID: 17356138 [TBL] [Abstract][Full Text] [Related]
6. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study. Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673 [TBL] [Abstract][Full Text] [Related]
7. Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period. deSouza RM; Parsons NR; Oni T; Dalton P; Costa M; Krikler S J Bone Joint Surg Br; 2010 Dec; 92(12):1642-7. PubMed ID: 21119168 [TBL] [Abstract][Full Text] [Related]
8. Metal ion levels in patients with a lumbar metal-on-metal total disc replacement: should we be concerned? Bisseling P; Zeilstra DJ; Hol AM; van Susante JL J Bone Joint Surg Br; 2011 Jul; 93(7):949-54. PubMed ID: 21705569 [TBL] [Abstract][Full Text] [Related]
9. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study. Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230 [TBL] [Abstract][Full Text] [Related]
10. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. Vendittoli PA; Mottard S; Roy AG; Dupont C; Lavigne M J Bone Joint Surg Br; 2007 Apr; 89(4):441-8. PubMed ID: 17463109 [TBL] [Abstract][Full Text] [Related]
11. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. Langton DJ; Jameson SS; Joyce TJ; Webb J; Nargol AV J Bone Joint Surg Br; 2008 Sep; 90(9):1143-51. PubMed ID: 18757952 [TBL] [Abstract][Full Text] [Related]
12. Changes in cobalt and chromium levels after metal-on-metal hip resurfacing in young, active Chinese patients. Yang J; Shen B; Zhou Z; Pei F; Kang P J Arthroplasty; 2011 Jan; 26(1):65-70, 70.e1. PubMed ID: 20171050 [TBL] [Abstract][Full Text] [Related]
13. Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. Clarke MT; Lee PT; Arora A; Villar RN J Bone Joint Surg Br; 2003 Aug; 85(6):913-7. PubMed ID: 12931818 [TBL] [Abstract][Full Text] [Related]
14. Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties. Langton DJ; Sprowson AP; Joyce TJ; Reed M; Carluke I; Partington P; Nargol AV J Bone Joint Surg Br; 2009 Oct; 91(10):1287-95. PubMed ID: 19794161 [TBL] [Abstract][Full Text] [Related]
15. Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up. Dunstan E; Sanghrajka AP; Tilley S; Unwin P; Blunn G; Cannon SR; Briggs TW J Bone Joint Surg Br; 2005 May; 87(5):628-31. PubMed ID: 15855362 [TBL] [Abstract][Full Text] [Related]
16. Current in vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level. Khan M; Takahashi T; Kuiper JH; Sieniawska CE; Takagi K; Richardson JB J Orthop Res; 2006 Nov; 24(11):2029-35. PubMed ID: 16960848 [TBL] [Abstract][Full Text] [Related]
17. Differential distribution of cobalt, chromium, and nickel between whole blood, plasma and urine in patients after metal-on-metal (MoM) hip arthroplasty. Newton AW; Ranganath L; Armstrong C; Peter V; Roberts NB J Orthop Res; 2012 Oct; 30(10):1640-6. PubMed ID: 22447496 [TBL] [Abstract][Full Text] [Related]
18. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949 [TBL] [Abstract][Full Text] [Related]
19. Metal ion levels from well-functioning Birmingham Hip Resurfacings decline significantly at ten years. Van Der Straeten C; Van Quickenborne D; De Roest B; Calistri A; Victor J; De Smet K Bone Joint J; 2013 Oct; 95-B(10):1332-8. PubMed ID: 24078528 [TBL] [Abstract][Full Text] [Related]
20. 2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial. Engh CA; MacDonald SJ; Sritulanondha S; Thompson A; Naudie D; Engh CA Clin Orthop Relat Res; 2009 Jan; 467(1):101-11. PubMed ID: 18855089 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]