BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 17323052)

  • 1. Evaluation and application of argon and helium microstrip plasma for the determination of mercury by the cold vapor technique and optical emission spectrometry.
    Jiménez Zapata I; Pohl P; Bings NH; Broekaert JA
    Anal Bioanal Chem; 2007 Aug; 388(8):1615-23. PubMed ID: 17323052
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A microwave-induced plasma based on microstrip technology and its use for the atomic emission spectrometric determination of mercury with the aid of the cold-vapor technique.
    Engel U; Bilgiç AM; Haase O; Voges E; Broekaert JA
    Anal Chem; 2000 Jan; 72(1):193-7. PubMed ID: 10655653
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization and comparison of chemical and electrochemical hydride generation for optical emission spectrometric determination of arsenic and antimony using a novel miniaturized microwave induced argon plasma exiting the microstrip wafer.
    Pohl P; Zapata IJ; Bings NH
    Anal Chim Acta; 2008 Jan; 606(1):9-18. PubMed ID: 18068765
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microplasma source based on a dielectric barrier discharge for the determination of mercury by atomic emission spectrometry.
    Zhu Z; Chan GC; Ray SJ; Zhang X; Hieftje GM
    Anal Chem; 2008 Nov; 80(22):8622-7. PubMed ID: 18937424
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mercury speciation by HPLC--cold-vapour radiofrequency glow-discharge optical-emission spectrometry with on-line microwave oxidation.
    Martínez R; Pereiro R; Sanz-Medel A; Bordel N
    Fresenius J Anal Chem; 2001 Nov; 371(6):746-52. PubMed ID: 11768461
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multivariate optimization of mercury determination by flow injection-cold vapor generation-inductively coupled plasma optical emission spectrometry.
    dos Santos VC; Grassi MT; de Campos MS; Peralta-Zamora PG; Abate G
    Analyst; 2012 Oct; 137(19):4458-63. PubMed ID: 22870503
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: initial test with elemental Hg.
    Sahay P; Scherrer ST; Wang C
    Rev Sci Instrum; 2012 Sep; 83(9):095109. PubMed ID: 23020421
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry.
    Leal LO; Elsholz O; Forteza R; Cerdà V
    Anal Chim Acta; 2006 Jul; 573-574():399-405. PubMed ID: 17723552
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Five Phase Digitally Controlled Rotating Field Plasma Source for Photochemical Mercury Vapor Generation Optical Emission Spectrometry.
    Matusiewicz H; Ślachciński M; Pawłowski P; Portalski M
    Anal Sci; 2015; 31(10):987-95. PubMed ID: 26460362
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of a solution cathode glow discharge for cold vapor generation of mercury with determination by ICP-atomic emission spectrometry.
    Zhu Z; Chan GC; Ray SJ; Zhang X; Hieftje GM
    Anal Chem; 2008 Sep; 80(18):7043-50. PubMed ID: 18710258
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Atomization of hydride with a low-temperature, atmospheric pressure dielectric barrier discharge and its application to arsenic speciation with atomic absorption spectrometry.
    Zhu Z; Zhang S; Lv Y; Zhang X
    Anal Chem; 2006 Feb; 78(3):865-72. PubMed ID: 16448062
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of mercury by intermittent flow electrochemical cold vapor generation coupled to atomic fluorescence spectrometry.
    Li X; Wang Z
    Anal Chim Acta; 2007 Apr; 588(2):179-83. PubMed ID: 17386808
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry.
    Frentiu T; Mihaltan AI; Ponta M; Darvasi E; Frentiu M; Cordos E
    J Hazard Mater; 2011 Oct; 193():65-9. PubMed ID: 21802847
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the coupling of hydride generation (HG) with flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) for determination of traces of As, Bi, Hg, Sb and Se by optical emission spectrometry (OES).
    Gorska M; Greda K; Pohl P
    Talanta; 2021 Jan; 222():121510. PubMed ID: 33167221
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mercury speciation in sea food by flow injection cold vapor atomic absorption spectrometry using selective solid phase extraction.
    Vereda Alonso E; Siles Cordero MT; García de Torres A; Cañada Rudner P; Cano Pavón JM
    Talanta; 2008 Oct; 77(1):53-9. PubMed ID: 18804598
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Slurry micro-sampling technique for use in argon-helium microwave induced plasma optical emission spectrometry.
    Ślachciński M
    Talanta; 2016 Dec; 161():812-818. PubMed ID: 27769487
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-precision measurement of mercury isotope ratios in sediments using cold-vapor generation multi-collector inductively coupled plasma mass spectrometry.
    Foucher D; Hintelmann H
    Anal Bioanal Chem; 2006 Apr; 384(7-8):1470-8. PubMed ID: 16550418
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Online YPA4 resin microcolumn separation/preconcentration coupled with inductively coupled plasma optical emission spectrometry (ICP-OES) for the speciation analysis of mercury in seafood.
    Xiong C; Hu B
    J Agric Food Chem; 2007 Dec; 55(25):10129-34. PubMed ID: 18031005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flowing Liquid Anode Atmospheric Pressure Glow Discharge as an Excitation Source for Optical Emission Spectrometry with the Improved Detectability of Ag, Cd, Hg, Pb, Tl, and Zn.
    Greda K; Swiderski K; Jamroz P; Pohl P
    Anal Chem; 2016 Sep; 88(17):8812-20. PubMed ID: 27476678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a new electrolytic cold vapor generation system for mercury determination by AFS.
    Zhang WB; Su ZF; Chu XF; Yang XA
    Talanta; 2010 Mar; 80(5):2106-12. PubMed ID: 20152459
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.