These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 17325596)

  • 1. An improved equation for correcting slope-intercept measurements of glomerular filtration rate for the single exponential approximation.
    Fleming JS
    Nucl Med Commun; 2007 Apr; 28(4):315-20. PubMed ID: 17325596
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Re-evaluation of the new Jodal-Brochner-Mortensen equation for one-pool correction of slope-intercept measurement of glomerular filtration rate.
    Peters AM
    Nucl Med Commun; 2011 May; 32(5):375-80. PubMed ID: 21301378
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reference data for 51Cr-EDTA measurements of the glomerular filtration rate derived from live kidney donors.
    Grewal GS; Blake GM
    Nucl Med Commun; 2005 Jan; 26(1):61-5. PubMed ID: 15604949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A general equation for estimating glomerular filtration rate from a single plasma sample.
    Fleming JS; Persaud L; Zivanovic MA
    Nucl Med Commun; 2005 Aug; 26(8):743-8. PubMed ID: 16000995
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correction of the slope-intercept method for the measurement of glomerular filtration rate.
    Blake GM; Barnfield MC; Burniston MT; Fleming JS; Cosgriff PS; Siddique M
    Nucl Med Commun; 2014 Dec; 35(12):1277-83. PubMed ID: 25211625
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality control of slope-intercept measurements of glomerular filtration rate using single-sample estimates.
    Fleming JS; Persaud L; Zivanovic MA
    Nucl Med Commun; 2005 Aug; 26(8):737-42. PubMed ID: 16000994
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The kinetic basis of glomerular filtration rate measurement and new concepts of indexation to body size.
    Peters AM
    Eur J Nucl Med Mol Imaging; 2004 Jan; 31(1):137-49. PubMed ID: 14593500
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A systematic review of single-sample glomerular filtration rate measurement techniques and demonstration of equal accuracy to slope-intercept methods.
    McMeekin H; Wickham F; Barnfield M; Burniston M
    Nucl Med Commun; 2016 Jul; 37(7):743-55. PubMed ID: 26626551
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Indexing glomerular filtration rate to suit children.
    Bird NJ; Henderson BL; Lui D; Ballinger JR; Peters AM
    J Nucl Med; 2003 Jul; 44(7):1037-43. PubMed ID: 12843217
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of formulae for accurate measurement of the glomerular filtration rate by renal dynamic imaging.
    Li Q; Zhang CL; Fu ZL; Wang RF; Ma YC; Zuo L
    Nucl Med Commun; 2007 May; 28(5):407-13. PubMed ID: 17414891
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prediction of two-sample (99m)Tc-diethylene triamine pentaacetic acid plasma clearance from single-sample method.
    Zuo L; Ying-Chun ; Wang M; Zhang CL; Wang RF; Wang HY
    Ann Nucl Med; 2005 Jul; 19(5):399-405. PubMed ID: 16164197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correction factors after having neglected the first exponential in the estimation of chromium-51 EDTA clearance: a reappraisal.
    De Sadeleer C; Piepsz A; Ham HR
    Ann Nucl Med; 2006 Feb; 20(2):95-8. PubMed ID: 16615417
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Post-test quality control for the single blood sample technique in glomerular filtration rate measurement in children.
    De Sadeleer C; Piepsz A; Ham HR
    Nucl Med Commun; 2006 Mar; 27(3):255-60. PubMed ID: 16479245
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pixel-by-pixel mean transit time without deconvolution.
    Dobbeleir AA; Piepsz A; Ham HR
    Nucl Med Commun; 2008 Apr; 29(4):345-8. PubMed ID: 18317298
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Slope-only glomerular filtration rate and single-sample glomerular filtration rate as measurements of the ratio of glomerular filtration rate to extracellular fluid volume.
    Peters AM; Glass DM; Bird NJ
    Nephrology (Carlton); 2010 Apr; 15(3):281-7. PubMed ID: 20470295
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Age-specific normal reference ranges for
    Gautam S
    Phys Eng Sci Med; 2021 Dec; 44(4):1331-1340. PubMed ID: 34694586
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New sampling strategy using a Bayesian approach to assess iohexol clearance in kidney transplant recipients.
    Benz-de Bretagne I; Le Guellec C; Halimi JM; Gatault P; Barbet C; Alnajjar A; Büchler M; Lebranchu Y; Andres CR; Vourcʼh P; Blasco H
    Ther Drug Monit; 2012 Jun; 34(3):289-97. PubMed ID: 22585184
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: monte carlo simulation approach demonstrated with gadolinium MR renography.
    Zhang JL; Conlin CC; Carlston K; Xie L; Kim D; Morrell G; Morton K; Lee VS
    NMR Biomed; 2016 Jul; 29(7):969-77. PubMed ID: 27200499
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of non-polynomial equations for one-compartment correction of slope-intercept GFR: theoretical prediction and experimental measurement.
    Finch NC; Heiene R; Bird NJ; Elliott J; Peters AM
    Scand J Clin Lab Invest; 2014 Oct; 74(7):611-9. PubMed ID: 25017421
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simple method for measuring severely reduced glomerular filtration rate.
    White AJ; Rachalewska M; Venkannagari RR
    J Nucl Med Technol; 2000 Sep; 28(3):173-5. PubMed ID: 11001500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.