240 related articles for article (PubMed ID: 17327658)
1. Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID.
Budgell GJ; Zhang R; Mackay RI
Phys Med Biol; 2007 Mar; 52(6):1721-33. PubMed ID: 17327658
[TBL] [Abstract][Full Text] [Related]
2. Improving IMRT quality control efficiency using an amorphous silicon electronic portal imager.
Budgell GJ; Zhang Q; Trouncer RJ; Mackay RI
Med Phys; 2005 Nov; 32(11):3267-78. PubMed ID: 16370416
[TBL] [Abstract][Full Text] [Related]
3. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
Baker SJ; Budgell GJ; MacKay RI
Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
[TBL] [Abstract][Full Text] [Related]
4. [Application of amorphous silicon electronic portal imaging device (a-Si EPID) to dosimetry quality assurance of radiation therapy].
Chen MW; Deng XW; Huang SM; Chen L; Kang DH
Ai Zheng; 2007 Nov; 26(11):1272-5. PubMed ID: 17991332
[TBL] [Abstract][Full Text] [Related]
5. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
Tyner E; McClean B; McCavana P; af Wetterstedt S
Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
[TBL] [Abstract][Full Text] [Related]
6. Fast, daily linac verification for segmented IMRT using electronic portal imaging.
Vieira SC; Bolt RA; Dirkx ML; Visser AG; Heijmen BJ
Radiother Oncol; 2006 Jul; 80(1):86-92. PubMed ID: 16854483
[TBL] [Abstract][Full Text] [Related]
7. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.
Greer PB; Vial P; Oliver L; Baldock C
Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504
[TBL] [Abstract][Full Text] [Related]
8. Investigation of an amorphous silicon EPID for measurement and quality assurance of enhanced dynamic wedge.
Greer PB; Barnes MP
Phys Med Biol; 2007 Feb; 52(4):1075-87. PubMed ID: 17264371
[TBL] [Abstract][Full Text] [Related]
9. Treatment planning and delivery of IMRT using 6 and 18MV photon beams without flattening filter.
Stathakis S; Esquivel C; Gutierrez A; Buckey CR; Papanikolaou N
Appl Radiat Isot; 2009 Sep; 67(9):1629-37. PubMed ID: 19369083
[TBL] [Abstract][Full Text] [Related]
10. The characterization of unflattened photon beams from a 6 MV linear accelerator.
Cashmore J
Phys Med Biol; 2008 Apr; 53(7):1933-46. PubMed ID: 18364548
[TBL] [Abstract][Full Text] [Related]
11. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.
Ding A; Xing L; Han B
Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618
[TBL] [Abstract][Full Text] [Related]
12. An empirical model of electronic portal imager response implemented within a commercial treatment planning system for verification of intensity-modulated radiation therapy fields.
Khan RFH; Ostapiak OZ; Szabo JJ
J Appl Clin Med Phys; 2008 Nov; 9(4):135-150. PubMed ID: 19020485
[TBL] [Abstract][Full Text] [Related]
13. Quality assurance measurements of a-Si EPID performance.
Menon GV; Sloboda RS
Med Dosim; 2004; 29(1):11-7. PubMed ID: 15023388
[TBL] [Abstract][Full Text] [Related]
14. Daily QA of linear accelerators using only EPID and OBI.
Sun B; Goddu SM; Yaddanapudi S; Noel C; Li H; Cai B; Kavanaugh J; Mutic S
Med Phys; 2015 Oct; 42(10):5584-94. PubMed ID: 26429233
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the veridose QC phantom.
Meigooni AS; Myron G; Sowards KT
Med Dosim; 2003; 28(1):49-54. PubMed ID: 12747620
[TBL] [Abstract][Full Text] [Related]
16. Analysis of quality control data of eight modern radiotherapy linear accelerators: the short- and long-term behaviours of the outputs and the reproducibility of quality control measurements.
Kapanen M; Tenhunen M; Hämäläinen T; Sipilä P; Parkkinen R; Järvinen H
Phys Med Biol; 2006 Jul; 51(14):3581-92. PubMed ID: 16825750
[TBL] [Abstract][Full Text] [Related]
17. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.
Hoffman D; Chung E; Hess C; Stern R; Benedict S
J Appl Clin Med Phys; 2017 Jan; 18(1):40-48. PubMed ID: 28291937
[TBL] [Abstract][Full Text] [Related]
18. Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance.
Lim S; Ma SY; Jeung TS; Yi BY; Lee SH; Lee S; Cho SJ; Choi J
Med Dosim; 2012; 37(3):296-304. PubMed ID: 22277157
[TBL] [Abstract][Full Text] [Related]
19. Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device.
Greer PB
Med Phys; 2007 Oct; 34(10):3815-24. PubMed ID: 17985627
[TBL] [Abstract][Full Text] [Related]
20. A beam-matching concept for medical linear accelerators.
Sjöström D; Bjelkengren U; Ottosson W; Behrens CF
Acta Oncol; 2009; 48(2):192-200. PubMed ID: 18752079
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]