These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 1733582)

  • 21. Blood chemistry by disposable ISE with the Chempro 500 system.
    Gourmelin Y; Andriamahatratra R; Gouget B; Truchaud A
    Ann Biol Clin (Paris); 1989; 47(10):597-600. PubMed ID: 2624332
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Factitiously high sodium activities on the Ektachem 400 owing to interferences by high gamma-globulin concentrations.
    Eastep SJ; Benson PJ; Preese LM; Apple FS
    Clin Chem; 1989 Feb; 35(2):333-4. PubMed ID: 2464446
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pseudohyponatremia.
    Aw TC; Kiechle FL
    Am J Emerg Med; 1985 May; 3(3):236-9. PubMed ID: 3994801
    [TBL] [Abstract][Full Text] [Related]  

  • 24. More on direct potentiometry--the ion-selective electrode vs flame photometry.
    Czaban JD; Cormier AD
    Clin Chem; 1980 Dec; 26(13):1921-4. PubMed ID: 7438449
    [No Abstract]   [Full Text] [Related]  

  • 25. Generation 04 sodium slides and generation 04 reference fluid evaluated for use with the Ektachem 400 Analyzer.
    Jack RM; Noble W
    Clin Chem; 1987 Jun; 33(6):845-7. PubMed ID: 3594832
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Relationship between direct-potentiometric and flame-photometric measurement of sodium in blood.
    Apple FS; Koch DD; Graves S; Ladenson JH
    Clin Chem; 1982 Sep; 28(9):1931-5. PubMed ID: 7127808
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca.
    Koch DD; Parrish D; Ladenson JH
    Clin Chem; 1983 Jun; 29(6):1090-2. PubMed ID: 6851101
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Assessment of potassium and sodium ion concentrations in the vitreous humour of swine isolated eyeballs after organism death.
    BrzeziƄski PM; Godlewski A
    Rocz Akad Med Bialymst; 2004; 49 Suppl 1():161-3. PubMed ID: 15638408
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Spuriously low concentrations of serum iron measured with generation 14 Kodak Ektachem slides: prevalence, possible causes, and partial improvement with generation 16 slides.
    Kempinaire A; Laureys M; Goedhuys W; Demeulemeester L; Sevens C; Smeyers-Verbeke J; Cooreman W; Neels H; Gorus FK
    Clin Chem; 1992 Dec; 38(12):2457-64. PubMed ID: 1281051
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Direct potentiometric determination of sodium ion in blood. III. Influence of (bi)carbonate.
    Boink FB; Bijster P; Vink KL; Maas AH
    Clin Chem; 1985 Apr; 31(4):523-6. PubMed ID: 2983905
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.
    Anker P; Jenny HB; Wuthier U; Asper R; Ammann D; Simon W
    Clin Chem; 1983 Aug; 29(8):1508-12. PubMed ID: 6872210
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intermethod variability of sodium and potassium results: patients' sera and commercially available control sera.
    Cattozzo G; Fabi A; Franzini C
    Eur J Clin Chem Clin Biochem; 1997 May; 35(5):387-92. PubMed ID: 9189744
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Discrepancies between sodium concentrations measured by the Kodak Ektachem 700 and by dilutional and direct ion-selective electrode analyzers.
    Stone JA; Moriguchi JR; Notto DR; Murphy PE; Dass CJ; Wessels LM; Freier EF
    Clin Chem; 1992 Dec; 38(12):2419-22. PubMed ID: 1458577
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of an instrument (Nova-1) for direct potentiometric analysis of sodium and potassium in blood and their indirect potentiometric determination in urine.
    Ladenson JH
    Clin Chem; 1979 May; 25(5):757-63. PubMed ID: 35288
    [No Abstract]   [Full Text] [Related]  

  • 35. Effect of moderate hypercholesterolemia on recognition of hypernatremia using indirect measurements of serum sodium and potassium concentrations.
    Naskalski JW; Solnica B; Gernand W
    Clin Lab; 2007; 53(7-8):441-7. PubMed ID: 17821948
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical evaluation of Eastman Kodak's Ektachem 400 Analyzer.
    Kadinger CL; O'Kell RT
    Clin Chem; 1983 Mar; 29(3):498-501. PubMed ID: 6825262
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ionometry versus flame photometry in dialysis therapy.
    Stiller S; Mann H
    Life Support Syst; 1985; 3 Suppl 1():63-7. PubMed ID: 3870623
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Indirect ion selective electrode methods potentially overestimate peritoneal dialysate sodium losses.
    Persaud J; Thomas M; Davenport A
    Ther Apher Dial; 2014 Aug; 18(4):321-5. PubMed ID: 24206257
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Comparison of ion-selective electrodes and flame photometry for the determination of serum Na+ and K+ for clinical purposes (author's transl)].
    Preusse CJ; Fuchs C
    J Clin Chem Clin Biochem; 1979 Oct; 17(10):639-45. PubMed ID: 501292
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An evaluation of the Ektachem serum lithium method and comparison with flame emission spectrometry.
    Frezzotti A; Margarucci AM; Coppa G; De Sio G
    Scand J Clin Lab Invest; 1996 Nov; 56(7):591-6. PubMed ID: 8981654
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.