183 related articles for article (PubMed ID: 17360221)
41. Abdominal aortic pseudoaneurysm managed with endovascular stent graft.
Hower J; Burton E; Agrawal ST; Simone S; Stahlfeld K
Surg Laparosc Endosc Percutan Tech; 2009 Jun; 19(3):e106-8. PubMed ID: 19542831
[TBL] [Abstract][Full Text] [Related]
42. Modeling pulsatile flow in aortic aneurysms: effect of non-Newtonian properties of blood.
Khanafer KM; Gadhoke P; Berguer R; Bull JL
Biorheology; 2006; 43(5):661-79. PubMed ID: 17047283
[TBL] [Abstract][Full Text] [Related]
43. Dilatation of stent-grafts by luminal pressures: experimental evaluation of polytetrafluoroethylene (PTFE) and woven polyester grafts.
Suzuki K; Ishiguchi T; Kawatsu S; Iwai H; Maruyama K; Ishigaki T
Cardiovasc Intervent Radiol; 2001; 24(2):94-8. PubMed ID: 11443393
[TBL] [Abstract][Full Text] [Related]
44. Modeling of antegrade and retrograde flow into a branch artery of the aorta: implications for endovascular stent-grafting and extra-anatomical visceral bypass.
Sutalo ID; Lawrence-Brown MM; Ahmed S; Liffman K; Semmens JB
J Endovasc Ther; 2008 Jun; 15(3):300-9. PubMed ID: 18540695
[TBL] [Abstract][Full Text] [Related]
45. Impact of the volume of aneurysmal contents on intraaneurysmal pressure after endovascular grafting (experimental studies).
Volodos' SN; Sayers RD; Bell PR; Gostelow JP
Angiol Sosud Khir; 2005; 11(4):64-71. PubMed ID: 16474292
[TBL] [Abstract][Full Text] [Related]
46. Impact of aortic grafts on arterial pressure: a computational fluid dynamics study.
Vardoulis O; Coppens E; Martin B; Reymond P; Tozzi P; Stergiopulos N
Eur J Vasc Endovasc Surg; 2011 Nov; 42(5):704-10. PubMed ID: 21889370
[TBL] [Abstract][Full Text] [Related]
47. An aortic model for the physiological assessment of endovascular stent-grafts.
Desai M; Ahmed M; Darbyshire A; You Z; Hamilton G; Seifalian AM
Ann Vasc Surg; 2011 May; 25(4):530-7. PubMed ID: 21439773
[TBL] [Abstract][Full Text] [Related]
48. Endotension is influenced by wall compliance in a latex aneurysm model.
Gawenda M; Knez P; Winter S; Jaschke G; Wassmer G; Schmitz-Rixen T; Brunkwall J
Eur J Vasc Endovasc Surg; 2004 Jan; 27(1):45-50. PubMed ID: 14652836
[TBL] [Abstract][Full Text] [Related]
49. Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation.
Litwak KN; Koenig SC; Cheng RC; Giridharan GA; Gillars KJ; Pantalos GM
Artif Organs; 2005 Aug; 29(8):629-35. PubMed ID: 16048479
[TBL] [Abstract][Full Text] [Related]
50. A sutureless aortic stent-graft based on a nitinol scaffold bonded to a compliant nanocomposite polymer is durable for 10 years in a simulated in vitro model.
Desai M; Bakhshi R; Zhou X; Odlyha M; You Z; Seifalian AM; Hamilton G
J Endovasc Ther; 2012 Jun; 19(3):415-27. PubMed ID: 22788896
[TBL] [Abstract][Full Text] [Related]
51. Assessment of stenosis in vascular access grafts.
Van Tricht I; De Wachter D; Vanhercke D; Tordoir J; Verdonck P
Artif Organs; 2004 Jul; 28(7):617-22. PubMed ID: 15209853
[TBL] [Abstract][Full Text] [Related]
52. Measurement of pulsatile haemodynamic forces in a model of a bifurcated stent graft for abdominal aortic aneurysm repair.
Zhou SN; How TV; Black RA; Vallabhaneni SR; McWilliams R; Brennan JA
Proc Inst Mech Eng H; 2008 May; 222(4):543-9. PubMed ID: 18595363
[TBL] [Abstract][Full Text] [Related]
53. Turbulence significantly increases pressure and fluid shear stress in an aortic aneurysm model under resting and exercise flow conditions.
Khanafer KM; Bull JL; Upchurch GR; Berguer R
Ann Vasc Surg; 2007 Jan; 21(1):67-74. PubMed ID: 17349339
[TBL] [Abstract][Full Text] [Related]
54. In vitro analysis of modular aortic stent-graft failure.
Hinchliffe RJ; Natarajan S; Hopkinson BR
J Endovasc Ther; 2006 Feb; 13(1):77-84. PubMed ID: 16445327
[TBL] [Abstract][Full Text] [Related]
55. Effects of compliance mismatch on blood flow in an artery with endovascular prosthesis.
Surovtsova I
J Biomech; 2005 Oct; 38(10):2078-86. PubMed ID: 16084208
[TBL] [Abstract][Full Text] [Related]
56. Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs.
Dobson G; Flewitt J; Tyberg JV; Moore R; Karamanoglu M
Eur J Vasc Endovasc Surg; 2006 Aug; 32(2):129-35. PubMed ID: 16564712
[TBL] [Abstract][Full Text] [Related]
57. Compliance properties of conduits used in vascular reconstruction.
Tai NR; Salacinski HJ; Edwards A; Hamilton G; Seifalian AM
Br J Surg; 2000 Nov; 87(11):1516-24. PubMed ID: 11091239
[TBL] [Abstract][Full Text] [Related]
58. Hemodynamic consequences of replacing the aorta by vascular grafts simulated in a mathematical model.
Schulz S; Bauernschmitt R; Schwarzhaupt A; Vahl CF; Kiencke U
Biomed Sci Instrum; 1997; 34():263-8. PubMed ID: 9603050
[TBL] [Abstract][Full Text] [Related]
59. Aneurysm sac pressure monitoring: effect of pulsatile motion of the pressure sensor on the interpretation of measurements.
Hinnen JW; Koning OH; Vlaanderen E; van Bockel JH; Hamming JF
J Endovasc Ther; 2006 Apr; 13(2):145-51. PubMed ID: 16643068
[TBL] [Abstract][Full Text] [Related]
60. Flow patterns in an endovascular stent-graft for abdominal aortic aneurysm repair.
Chong CK; How TV
J Biomech; 2004 Jan; 37(1):89-97. PubMed ID: 14672572
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]