These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
347 related articles for article (PubMed ID: 17367872)
1. A simple competitive RT-PCR assay for quantitation of HIV-1 subtype B and non-B RNA in plasma. Hamatake M; Nishizawa M; Yamamoto N; Kato S; Sugiura W J Virol Methods; 2007 Jun; 142(1-2):113-7. PubMed ID: 17367872 [TBL] [Abstract][Full Text] [Related]
2. Comparative evaluation of the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test and the Versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples. Berger A; Scherzed L; Stürmer M; Preiser W; Doerr HW; Rabenau HF J Clin Virol; 2005 May; 33(1):43-51. PubMed ID: 15797364 [TBL] [Abstract][Full Text] [Related]
3. Clinical comparison of branched DNA and reverse transcriptase-PCR and nucleic acid sequence-based amplification assay for the quantitation of circulating recombinant form_BC HIV-1 RNA in plasma. Pan P; Tao X; Zhang Q; Xing W; Sun X; Pei L; Jiang Y AIDS; 2007 Dec; 21 Suppl 8():S27-32. PubMed ID: 18172387 [TBL] [Abstract][Full Text] [Related]
4. Comparison of the Generic HIV Viral Load assay with the Amplicor HIV-1 monitor v1.5 and Nuclisens HIV-1 EasyQ v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: the Kesho Bora preparatory study. Rouet F; Foulongne V; Viljoen J; Steegen K; Becquart P; Valéa D; Danaviah S; Segondy M; Verhofstede C; Van de Perre P; J Virol Methods; 2010 Feb; 163(2):253-7. PubMed ID: 19837114 [TBL] [Abstract][Full Text] [Related]
5. Quantitation of HIV-1 RNA levels in plasma and CSF of asymptomatic HIV-1 infected patients from South India using a TaqMan real time PCR assay. Kamat A; Ravi V; Desai A; Satishchandra P; Satish KS; Borodowsky I; Subbakrishna DK; Kumar M J Clin Virol; 2007 May; 39(1):9-15. PubMed ID: 17368087 [TBL] [Abstract][Full Text] [Related]
6. Measurement of HIV RNA in patients infected by subtype C by assays optimized for subtype B results in an underestimation of the viral load. Gottesman BS; Grosman Z; Lorber M; Levi I; Shitrit P; Mileguir F; Gottesman G; Chowers MY J Med Virol; 2004 Jun; 73(2):167-71. PubMed ID: 15122788 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses. Swanson P; Huang S; Abravaya K; de Mendoza C; Soriano V; Devare SG; Hackett J J Virol Methods; 2007 Apr; 141(1):49-57. PubMed ID: 17184853 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of the NucliSens EasyQ HIV-1 v1.1 and RealTime HIV-1 kits for quantitation of HIV-1 RNA in plasma. Choi JY; Kim EJ; Rho HJ; Kim JY; Kwon OK; Lee JH; Koo MJ; Kim SS J Virol Methods; 2009 Oct; 161(1):7-11. PubMed ID: 19576640 [TBL] [Abstract][Full Text] [Related]
9. A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A-H, group O and group N samples. Tang N; Huang S; Salituro J; Mak WB; Cloherty G; Johanson J; Li YH; Schneider G; Robinson J; Hackett J; Swanson P; Abravaya K J Virol Methods; 2007 Dec; 146(1-2):236-45. PubMed ID: 17707519 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of two commercially available, inexpensive alternative assays used for assessing viral load in a cohort of human immunodeficiency virus type 1 subtype C-infected patients from South Africa. Stevens G; Rekhviashvili N; Scott LE; Gonin R; Stevens W J Clin Microbiol; 2005 Feb; 43(2):857-61. PubMed ID: 15695692 [TBL] [Abstract][Full Text] [Related]
11. Comprehensive comparison of the VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 MONITOR 1.5 assays on 1,000 clinical specimens. Galli R; Merrick L; Friesenhahn M; Ziermann R J Clin Virol; 2005 Dec; 34(4):245-52. PubMed ID: 16286047 [TBL] [Abstract][Full Text] [Related]
12. Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals. Taylor N; Schmid I; Egle A; Greil R; Patsch W; Oberkofler H Antivir Ther; 2009; 14(8):1189-93. PubMed ID: 20032549 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of NucliSens EasyQ HIV-1 assay for quantification of HIV-1 subtypes prevalent in South-east Asia. Lam HY; Chen JH; Wong KH; Chan K; Li P; Lee MP; Tsang DN; Yuen KY; Yam WC J Clin Virol; 2007 Jan; 38(1):39-43. PubMed ID: 17110162 [TBL] [Abstract][Full Text] [Related]
14. Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from London: comparison to VERSANT HIV-1 RNA 3.0, AMPLICOR HIV-1 MONITOR v1.5, and LCx HIV RNA Quantitative assays. Swanson P; Holzmayer V; Huang S; Hay P; Adebiyi A; Rice P; Abravaya K; Thamm S; Devare SG; Hackett J J Virol Methods; 2006 Nov; 137(2):184-92. PubMed ID: 16876263 [TBL] [Abstract][Full Text] [Related]
15. A sensitive in-house RT-PCR genotyping system for combined detection of plasma HIV-1 and assessment of drug resistance. Steegen K; Demecheleer E; De Cabooter N; Nges D; Temmerman M; Ndumbe P; Mandaliya K; Plum J; Verhofstede C J Virol Methods; 2006 May; 133(2):137-45. PubMed ID: 16375980 [TBL] [Abstract][Full Text] [Related]
16. Quantitative detection of human immunodeficiency virus type 1 (HIV-1) viral load by real-time RT-PCR assay using self-quenched fluorogenic primers. Promso S; Srichunrusami C; Utid K; Lulitanond V; Pairoj W; Chantratita W Southeast Asian J Trop Med Public Health; 2006 May; 37(3):477-87. PubMed ID: 17120967 [TBL] [Abstract][Full Text] [Related]
17. The first B/G intersubtype recombinant form of human immunodeficiency virus type 1 (HIV-1) identified in Germany was undetected or underquantitated by some commercial viral load assays. von Truchsess I; Harris B; Schätzl HM; Hackett J J Med Virol; 2006 Mar; 78(3):311-7. PubMed ID: 16419111 [TBL] [Abstract][Full Text] [Related]
18. High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes. Karasi JC; Dziezuk F; Quennery L; Förster S; Reischl U; Colucci G; Schoener D; Seguin-Devaux C; Schmit JC J Clin Virol; 2011 Nov; 52(3):181-6. PubMed ID: 21813320 [TBL] [Abstract][Full Text] [Related]
19. Quantitation of human immunodeficiency virus type 1 viral load in plasma using reverse transcriptase activity assay at a district hospital laboratory in Botswana: a decentralization pilot study. Mine M; Bedi K; Maruta T; Madziva D; Tau M; Zana T; Gaolathe T; Moyo S; Seipone K; Ndwapi N; Essex M; Marlink R J Virol Methods; 2009 Jul; 159(1):93-7. PubMed ID: 19442851 [TBL] [Abstract][Full Text] [Related]
20. Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma. Coste J; Montes B; Reynes J; Peeters M; Segarra C; Vendrell JP; Delaporte E; Segondy M J Med Virol; 1996 Dec; 50(4):293-302. PubMed ID: 8950685 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]