These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
238 related articles for article (PubMed ID: 17369268)
1. Unusual cause for an increase of the sensing integrity counter in a patient with inappropriate implantable cardioverter-defibrillator therapy. Vollmann D; Lüthje L; Zabel M Europace; 2007 May; 9(5):275-7. PubMed ID: 17369268 [TBL] [Abstract][Full Text] [Related]
2. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Spencker S; Coban N; Koch L; Schirdewan A; Müller D Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654 [TBL] [Abstract][Full Text] [Related]
3. Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias. Occhetta E; Bortnik M; Magnani A; Francalacci G; Marino P Europace; 2006 Oct; 8(10):863-9. PubMed ID: 16916859 [TBL] [Abstract][Full Text] [Related]
4. An algorithm to predict implantable cardioverter-defibrillator lead failure. Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026 [TBL] [Abstract][Full Text] [Related]
5. An unusual cause of oversensing leading to inappropriate ICD discharges. Spencker S; Poppelbaum A; Müller D Int J Cardiol; 2008 Sep; 129(1):e24-6. PubMed ID: 17669521 [TBL] [Abstract][Full Text] [Related]
7. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy. Strohmer B; Schernthaner C; Pichler M Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515 [TBL] [Abstract][Full Text] [Related]
8. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing. Gilliam FR J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033 [TBL] [Abstract][Full Text] [Related]
9. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead. Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072 [TBL] [Abstract][Full Text] [Related]
10. T-wave oversensing and inappropriate shocks: a case report. Srivathsan K; Scott LR; Altemose GT Europace; 2008 May; 10(5):552-5. PubMed ID: 18442965 [TBL] [Abstract][Full Text] [Related]
11. Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion. Duru F; Bauersfeld U; Candinas R Europace; 2001 Jan; 3(1):80-4. PubMed ID: 11271957 [TBL] [Abstract][Full Text] [Related]
12. T wave oversensing by a cardioverter defibrillator implanted in a patient with the Brugada syndrome. Porres JM; Brugada J; Marco P; García F; Azcarate B Pacing Clin Electrophysiol; 2004 Nov; 27(11):1563-5. PubMed ID: 15546314 [TBL] [Abstract][Full Text] [Related]
13. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
14. Inadequate ICD discharges due to diaphragmatic electromyopotential oversensing as the first sign of right ventricular lead perforation. Wiegand UK; Wilke I; Bonnemeier H; Eberhardt F; Bode F Pacing Clin Electrophysiol; 2006 Oct; 29(10):1176-8. PubMed ID: 17038150 [TBL] [Abstract][Full Text] [Related]
15. T-wave oversensing by an implantable cardioverter defibrillator after successful ablation of idiopathic ventricular fibrillation. Strohmer B; Schernthaner C; Pichler M Pacing Clin Electrophysiol; 2006 Apr; 29(4):431-5. PubMed ID: 16650276 [TBL] [Abstract][Full Text] [Related]
16. Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture. Gunderson BD; Swerdlow CD; Wilcox JM; Hayman JE; Ousdigian KT; Ellenbogen KA Heart Rhythm; 2010 May; 7(5):626-33. PubMed ID: 20184977 [TBL] [Abstract][Full Text] [Related]
17. Sensing lead insulation fractures following implantable cardioverter-defibrillator placement. Tedder M; Anstadt MP; Tedder SD; Revishvili AS; Hegde SS; Lowe JE ASAIO J; 1993; 39(3):M711-4. PubMed ID: 8268630 [TBL] [Abstract][Full Text] [Related]
18. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port. Maagh P; Trappe HJ; Meissner A Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694 [TBL] [Abstract][Full Text] [Related]
19. Resolution of T-wave oversensing with implantable cardioverter defibrillator generator replacement in an adolescent. Tuzcu V Pacing Clin Electrophysiol; 2007 Jul; 30(7):929-32. PubMed ID: 17584279 [TBL] [Abstract][Full Text] [Related]
20. A single implantable cardioverter-defibrillator shock unmasking an electrical storm of 389 ventricular tachycardia episodes triggering device therapies. Arias MA; Valverde I; Puchol A; Castellanos E; Rodríguez-Padial L; Sánchez AM; Alvarez-Temiño M; Palomino M Am J Emerg Med; 2008 Nov; 26(9):1066.e1-3. PubMed ID: 19091283 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]