179 related articles for article (PubMed ID: 17378540)
1. Real-time rolling circle amplification for protein detection.
Yang L; Fung CW; Cho EJ; Ellington AD
Anal Chem; 2007 May; 79(9):3320-9. PubMed ID: 17378540
[TBL] [Abstract][Full Text] [Related]
2. Universal aptameric system for highly sensitive detection of protein based on structure-switching-triggered rolling circle amplification.
Wu ZS; Zhang S; Zhou H; Shen GL; Yu R
Anal Chem; 2010 Mar; 82(6):2221-7. PubMed ID: 20151715
[TBL] [Abstract][Full Text] [Related]
3. Combination of aptamer with gold nanoparticles for electrochemical signal amplification: application to sensitive detection of platelet-derived growth factor.
Wang J; Meng W; Zheng X; Liu S; Li G
Biosens Bioelectron; 2009 Feb; 24(6):1598-602. PubMed ID: 18829294
[TBL] [Abstract][Full Text] [Related]
4. Triggered polycatenated DNA scaffolds for DNA sensors and aptasensors by a combination of rolling circle amplification and DNAzyme amplification.
Bi S; Li L; Zhang S
Anal Chem; 2010 Nov; 82(22):9447-54. PubMed ID: 20954711
[TBL] [Abstract][Full Text] [Related]
5. Aptamer-functionalized gold nanoparticles for turn-on light switch detection of platelet-derived growth factor.
Huang CC; Chiu SH; Huang YF; Chang HT
Anal Chem; 2007 Jul; 79(13):4798-804. PubMed ID: 17530743
[TBL] [Abstract][Full Text] [Related]
6. Direct optical detection of aptamer conformational changes induced by target molecules.
Neumann O; Zhang D; Tam F; Lal S; Wittung-Stafshede P; Halas NJ
Anal Chem; 2009 Dec; 81(24):10002-6. PubMed ID: 19928834
[TBL] [Abstract][Full Text] [Related]
7. Aptamer-based electrochemical detection of picomolar platelet-derived growth factor directly in blood serum.
Lai RY; Plaxco KW; Heeger AJ
Anal Chem; 2007 Jan; 79(1):229-33. PubMed ID: 17194144
[TBL] [Abstract][Full Text] [Related]
8. Aptamer-based rolling circle amplification: a platform for electrochemical detection of protein.
Zhou L; Ou LJ; Chu X; Shen GL; Yu RQ
Anal Chem; 2007 Oct; 79(19):7492-500. PubMed ID: 17722881
[TBL] [Abstract][Full Text] [Related]
9. Highly sensitive detection of platelet-derived growth factor on a functionalized diamond surface using aptamer sandwich design.
Ruslinda AR; Penmatsa V; Ishii Y; Tajima S; Kawarada H
Analyst; 2012 Apr; 137(7):1692-7. PubMed ID: 22349046
[TBL] [Abstract][Full Text] [Related]
10. Differentiation and detection of PDGF isomers and their receptors by tunable aptamer capillary electrophoresis.
Zhang H; Li XF; Le XC
Anal Chem; 2009 Sep; 81(18):7795-800. PubMed ID: 19691297
[TBL] [Abstract][Full Text] [Related]
11. Electrochemical aptameric recognition system for a sensitive protein assay based on specific target binding-induced rolling circle amplification.
Wu ZS; Zhou H; Zhang S; Shen G; Yu R
Anal Chem; 2010 Mar; 82(6):2282-9. PubMed ID: 20155943
[TBL] [Abstract][Full Text] [Related]
12. Coupled rolling circle amplification loop-mediated amplification for rapid detection of short DNA sequences.
Marciniak J; Kummel A; Esener S; Heller M; Messmer B
Biotechniques; 2008 Sep; 45(3):275-80. PubMed ID: 18778251
[TBL] [Abstract][Full Text] [Related]
13. Aptamer-modified gold nanoparticles for colorimetric determination of platelet-derived growth factors and their receptors.
Huang CC; Huang YF; Cao Z; Tan W; Chang HT
Anal Chem; 2005 Sep; 77(17):5735-41. PubMed ID: 16131089
[TBL] [Abstract][Full Text] [Related]
14. Arrest of rolling circle amplification by protein-binding DNA aptamers.
Wang L; Tram K; Ali MM; Salena BJ; Li J; Li Y
Chemistry; 2014 Feb; 20(9):2420-4. PubMed ID: 24590539
[TBL] [Abstract][Full Text] [Related]
15. A universal electrochemical sensing system for small biomolecules using target-mediated sticky ends-based ligation-rolling circle amplification.
Yi X; Li L; Peng Y; Guo L
Biosens Bioelectron; 2014 Jul; 57():103-9. PubMed ID: 24561524
[TBL] [Abstract][Full Text] [Related]
16. Selection and characterization of DNA aptamers against VEGF165 with aptamer blotting method and its application.
Ikebukuro K; Hasegawa H; Sode K
Nucleic Acids Symp Ser (Oxf); 2007; (51):399-400. PubMed ID: 18029755
[TBL] [Abstract][Full Text] [Related]
17. Double-probe signal enhancing strategy for toxin aptasensing based on rolling circle amplification.
Tong P; Zhao WW; Zhang L; Xu JJ; Chen HY
Biosens Bioelectron; 2012 Mar; 33(1):146-51. PubMed ID: 22270050
[TBL] [Abstract][Full Text] [Related]
18. Label-free aptasensor for platelet-derived growth factor (PDGF) protein.
Degefa TH; Kwak J
Anal Chim Acta; 2008 Apr; 613(2):163-8. PubMed ID: 18395055
[TBL] [Abstract][Full Text] [Related]
19. Cocaine detection via rolling circle amplification of short DNA strand separated by magnetic beads.
Ma C; Wang W; Yang Q; Shi C; Cao L
Biosens Bioelectron; 2011 Mar; 26(7):3309-12. PubMed ID: 21277763
[TBL] [Abstract][Full Text] [Related]
20. Chemiluminescent detection of DNA hybridization and single-nucleotide polymorphisms on a solid surface using target-primed rolling circle amplification.
Li Z; Li W; Cheng Y; Hao L
Analyst; 2008 Sep; 133(9):1164-8. PubMed ID: 18709189
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]