These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

508 related articles for article (PubMed ID: 17383521)

  • 1. Surgical specimen identification errors: a new measure of quality in surgical care.
    Makary MA; Epstein J; Pronovost PJ; Millman EA; Hartmann EC; Freischlag JA
    Surgery; 2007 Apr; 141(4):450-5. PubMed ID: 17383521
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Specimen labeling errors in surgical pathology: an 18-month experience.
    Layfield LJ; Anderson GM
    Am J Clin Pathol; 2010 Sep; 134(3):466-70. PubMed ID: 20716804
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A quality initiative to decrease pathology specimen-labeling errors using radiofrequency identification in a high-volume endoscopy center.
    Francis DL; Prabhakar S; Sanderson SO
    Am J Gastroenterol; 2009 Apr; 104(4):972-5. PubMed ID: 19259073
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Identification errors in pathology and laboratory medicine.
    Valenstein PN; Sirota RL
    Clin Lab Med; 2004 Dec; 24(4):979-96, vii. PubMed ID: 15555752
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mislabeling of cases, specimens, blocks, and slides: a college of american pathologists study of 136 institutions.
    Nakhleh RE; Idowu MO; Souers RJ; Meier FA; Bekeris LG
    Arch Pathol Lab Med; 2011 Aug; 135(8):969-74. PubMed ID: 21809987
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surgical pathology specimen identification and accessioning: A College of American Pathologists Q-Probes Study of 1 004 115 cases from 417 institutions.
    Nakhleh RE; Zarbo RJ
    Arch Pathol Lab Med; 1996 Mar; 120(3):227-33. PubMed ID: 8629896
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The loss of pathological specimens: incidence and causes.
    Sandbank S; Klein D; Westreich M; Shalom A
    Dermatol Surg; 2010 Jul; 36(7):1084-6. PubMed ID: 20533941
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical case listing accuracy: failure analysis at a high-volume academic medical center.
    Cima RR; Hale C; Kollengode A; Rogers JC; Cassivi SD; Deschamps C
    Arch Surg; 2010 Jul; 145(7):641-6. PubMed ID: 20644126
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Human error, not communication and systems, underlies surgical complications.
    Fabri PJ; Zayas-Castro JL
    Surgery; 2008 Oct; 144(4):557-63; discussion 563-5. PubMed ID: 18847639
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Laboratory errors as judged by test request slips and test reports.
    Siddiqui S
    J Coll Physicians Surg Pak; 2006 Feb; 16(2):136-8. PubMed ID: 16499809
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improving the accuracy of specimen labeling.
    Dock B
    Clin Lab Sci; 2005; 18(4):210-2. PubMed ID: 16315737
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardized patient identification and specimen labeling: a retrospective analysis on improving patient safety.
    Kim JK; Dotson B; Thomas S; Nelson KC
    J Am Acad Dermatol; 2013 Jan; 68(1):53-6. PubMed ID: 22841126
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?
    Suba EJ; Pfeifer JD; Raab SS
    J Urol; 2007 Oct; 178(4 Pt 1):1245-8. PubMed ID: 17698125
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduction in specimen labeling errors after implementation of a positive patient identification system in phlebotomy.
    Morrison AP; Tanasijevic MJ; Goonan EM; Lobo MM; Bates MM; Lipsitz SR; Bates DW; Melanson SE
    Am J Clin Pathol; 2010 Jun; 133(6):870-7. PubMed ID: 20472844
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A multidisciplinary, multifaceted improvement initiative to eliminate mislabelled laboratory specimens at a large tertiary care hospital.
    Seferian EG; Jamal S; Clark K; Cirricione M; Burnes-Bolton L; Amin M; Romanoff N; Klapper E
    BMJ Qual Saf; 2014 Aug; 23(8):690-7. PubMed ID: 24915540
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perioperative patient safety: correct patient, correct surgery, correct side--a multifaceted, cross-organizational, interventional study.
    Zohar E; Noga Y; Davidson E; Kantor M; Fredman B
    Anesth Analg; 2007 Aug; 105(2):443-7. PubMed ID: 17646503
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Specimen labeling QI project cuts error rate.
    Healthcare Benchmarks Qual Improv; 2006 Dec; 13(12):137-8. PubMed ID: 17153049
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Developing and pilot testing practical measures of preanalytic surgical specimen identification defects.
    Bixenstine PJ; Zarbo RJ; Holzmueller CG; Yenokyan G; Robinson R; Hudson DW; Prescott AM; Hubble R; Murphy MM; George CT; D'Angelo R; Watson SR; Lubomski LH; Berenholtz SM
    Am J Med Qual; 2013; 28(4):308-14. PubMed ID: 23322909
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pre-analytical workstations: a tool for reducing laboratory errors.
    Da Rin G
    Clin Chim Acta; 2009 Jun; 404(1):68-74. PubMed ID: 19302988
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rate of occult specimen provenance complications in routine clinical practice.
    Pfeifer JD; Liu J
    Am J Clin Pathol; 2013 Jan; 139(1):93-100. PubMed ID: 23270904
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.