These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

388 related articles for article (PubMed ID: 17386495)

  • 1. Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues.
    Resano M; Briceño J; Aramendía M; Belarra MA
    Anal Chim Acta; 2007 Jan; 582(2):214-22. PubMed ID: 17386495
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of using solid sampling graphite furnace atomic absorption spectrometry for speciation analysis of volatile and non-volatile compounds of nickel and vanadium in crude oil.
    Silva MM; Damin IC; Vale MG; Welz B
    Talanta; 2007 Mar; 71(5):1877-85. PubMed ID: 19071537
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver at trace and ultratrace levels.
    Resano M; Aramendía M; García-Ruiz E; Crespo C; Belarra MA
    Anal Chim Acta; 2006 Jun; 571(1):142-9. PubMed ID: 17723432
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chromium determination in pharmaceutical grade barium sulfate by solid sampling electrothermal atomic absorption spectrometry with Zeeman-effect background correction.
    Bolzan RC; Rodrigues LF; Mattos JC; Dressler VL; Flores EM
    Talanta; 2007 Nov; 74(1):119-24. PubMed ID: 18371620
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct sample introduction of wines in graphite furnace atomic absorption spectrometry for the simultaneous determination of arsenic, cadmium, copper and lead content.
    Ajtony Z; Szoboszlai N; Suskó EK; Mezei P; György K; Bencs L
    Talanta; 2008 Jul; 76(3):627-34. PubMed ID: 18585331
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry--determination of antimony in sediment reference materials using direct solid sampling.
    Araujo RG; Welz B; Vignola F; Becker-Ross H
    Talanta; 2009 Dec; 80(2):846-52. PubMed ID: 19836562
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of direct solid sampling and slurry sampling for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry.
    Araujo RG; Oleszczuk N; Rampazzo RT; Costa PA; Silva MM; Vale MG; Welz B; Ferreira SL
    Talanta; 2008 Oct; 77(1):400-6. PubMed ID: 18804652
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of total sulfur in food samples by solid sampling high-resolution continuum source graphite furnace molecular absorption spectrometry.
    Ozbek N; Akman S
    J Agric Food Chem; 2013 May; 61(20):4816-21. PubMed ID: 23635016
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling.
    Figuerêdo Rêgo J; Virgilio A; Nóbrega JA; Gomes Neto JA
    Talanta; 2012 Oct; 100():21-6. PubMed ID: 23141306
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow injection on-line dilution for zinc determination in human saliva with electrothermal atomic absorption spectrometry detection.
    Burguera-Pascu M; Rodríguez-Archilla A; Burguera JL; Burguera M; Rondón C; Carrero P
    Anal Chim Acta; 2007 Sep; 600(1-2):214-20. PubMed ID: 17903487
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [GFAAS determination of trace amount cadmium in chitosan by micro wave].
    Weng D; Zhai GQ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Apr; 25(4):567-9. PubMed ID: 16097687
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Direct determination of trace arsenic in coal by slurry-sampling graphite-furnace atomic absorption spectrometry].
    Chen SZ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Oct; 24(10):1267-9. PubMed ID: 15760039
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous and direct determination of iron and nickel in biological solid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry.
    Gómez-Nieto B; Gismera MJ; Sevilla MT; Procopio JR
    Talanta; 2013 Nov; 116():860-5. PubMed ID: 24148485
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Determination of beryllium in geological samples with slurry sampling and probe atomization in graphite furnace atomic absorption spectrometry].
    Hou S; Chang C
    Guang Pu Xue Yu Guang Pu Fen Xi; 1998 Feb; 18(1):73-6. PubMed ID: 15810338
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous determination of Cd and Fe in beans and soil of different regions of Brazil using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling.
    dos Santos LM; Welz B; Araujo RG; Jacob Sdo C; Vale MG; Martens A; Gonzaga Martens IB; Becker-Ross H
    J Agric Food Chem; 2009 Nov; 57(21):10089-94. PubMed ID: 19831412
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Liquid phase microextraction and ultratrace determination of cadmium by modified graphite furnace atomic absorption spectrometry.
    Nazari S
    J Hazard Mater; 2009 Jun; 165(1-3):200-5. PubMed ID: 19010596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Superiority of nitric acid for deproteinization in the determination of trace lithium in serum by graphite furnace atomic absorption spectrometry.
    Zhao J; Gao P; Wu S; Zhu D
    J Pharm Biomed Anal; 2009 Dec; 50(5):1075-9. PubMed ID: 19616397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ion-exchange preconcentration and determination of vanadium in milk samples by electrothermal atomic absorption spectrometry.
    López-García I; Viñas P; Romero-Romero R; Hernández-Córdoba M
    Talanta; 2009 Jun; 78(4-5):1458-63. PubMed ID: 19362217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry.
    dos Santos LM; Araujo RG; Welz B; Jacob Sdo C; Vale MG; Becker-Ross H
    Talanta; 2009 Apr; 78(2):577-83. PubMed ID: 19203627
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cadmium analysis in soil by microwave acid digestion and graphite furnace atomic absorption spectrometry.
    Carlosena A; Prada D; Andrade JM; López P; Muniategui S
    Anal Bioanal Chem; 1996 Jun; 355(3-4):289-91. PubMed ID: 15045388
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.