1. [Usefulness of low- and medium-energy collimators in 123I-MIBG myocardial scintigraphy].
Sakashita R; Sugimoto K; Fukuya Y; Fujibuchi H; Ishida T; Higashimura K; Tsuchida T
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2007 Feb; 63(2):241-6. PubMed ID: 17387245
[TBL] [Abstract][Full Text] [Related]
2. Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera-collimator combinations.
Matsuo S; Nakajima K; Okuda K; Kawano M; Ishikawa T; Hosoya T; Taki J; Kinuya S
Eur J Nucl Med Mol Imaging; 2009 Apr; 36(4):560-6. PubMed ID: 18989667
[TBL] [Abstract][Full Text] [Related]
3. ¹²³I-MIBG heart-to-mediastinum ratio is influenced by high-energy photon penetration of collimator septa from liver and lung activity.
Verschure DO; de Wit TC; Bongers V; Hagen PJ; Sonneck-Koenne C; D'Aron J; Huber K; van Eck-Smit BL; Knoll P; Somsen GA; Mirzaei S; Verberne HJ
Nucl Med Commun; 2015 Mar; 36(3):279-85. PubMed ID: 25415845
[TBL] [Abstract][Full Text] [Related]
4. Acquisition protocols and correction methods for estimation of the heart-to-mediastinum ratio in 123I-metaiodobenzylguanidine cardiac sympathetic imaging.
Inoue Y; Abe Y; Itoh Y; Asano Y; Kikuchi K; Sakamoto Y; Matsunaga K; Ogino Y; Iizuka T; Mochizuki H
J Nucl Med; 2013 May; 54(5):707-13. PubMed ID: 23536225
[TBL] [Abstract][Full Text] [Related]
5. Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake.
Inoue Y; Suzuki A; Shirouzu I; Machida T; Yoshizawa Y; Akita F; Ohnishi S; Yoshikawa K; Ohtomo K
J Nucl Cardiol; 2003; 10(6):623-32. PubMed ID: 14668774
[TBL] [Abstract][Full Text] [Related]
6. Correction of iodine-123-labeled meta-iodobenzylguanidine uptake with multi-window methods for standardization of the heart-to-mediastinum ratio.
Nakajima K; Matsubara K; Ishikawa T; Motomura N; Maeda R; Akhter N; Okuda K; Taki J; Kinuya S
J Nucl Cardiol; 2007; 14(6):843-51. PubMed ID: 18022111
[TBL] [Abstract][Full Text] [Related]
7. Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study.
Nakajima K; Okuda K; Matsuo S; Yoshita M; Taki J; Yamada M; Kinuya S
Eur J Nucl Med Mol Imaging; 2012 Jan; 39(1):113-9. PubMed ID: 22009380
[TBL] [Abstract][Full Text] [Related]
8. Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems.
Kobayashi H; Momose M; Kanaya S; Kondo C; Kusakabe K; Mitsuhashi N
Ann Nucl Med; 2003 Jun; 17(4):309-13. PubMed ID: 12932115
[TBL] [Abstract][Full Text] [Related]
9. Influence of collimator choice and simulated clinical conditions on 123I-MIBG heart/mediastinum ratios: a phantom study.
Verberne HJ; Feenstra C; de Jong WM; Somsen GA; van Eck-Smit BL; Busemann Sokole E
Eur J Nucl Med Mol Imaging; 2005 Sep; 32(9):1100-7. PubMed ID: 15902438
[TBL] [Abstract][Full Text] [Related]
10. An improved method for estimating the heart-to-mediastinum ratio from cardiac sympathetic nerve imaging with low-energy high-resolution collimators.
Inoue Y; Abe Y; Asano Y; Kikuchi K; Matsunaga K; Iizuka T; Nishiyama K
J Nucl Cardiol; 2014 Jun; 21(3):614-21. PubMed ID: 24715623
[TBL] [Abstract][Full Text] [Related]
11. Influence of high-energy photons on the spectrum of iodine-123 with low- and medium-energy collimators: consequences for imaging with 123I-labelled compounds in clinical practice.
Dobbeleir AA; Hambÿe AS; Franken PR
Eur J Nucl Med; 1999 Jun; 26(6):655-8. PubMed ID: 10369952
[TBL] [Abstract][Full Text] [Related]
12. Comparison of Taiwanese and European Calibration Factors for Heart-to-Mediastinum Ratio in Multicenter
Okuda K; Nakajima K; Hung GU; Wu HT; Verschure DO; Verberne HJ; Kitamura C
Ann Nucl Cardiol; 2023; 9(1):54-60. PubMed ID: 38058572
[No Abstract] [Full Text] [Related]
13. Cross calibration of
Nakajima K; Okuda K; Yokoyama K; Yoneyama T; Tsuji S; Oda H; Yoshita M; Kubota K
Ann Nucl Med; 2017 Oct; 31(8):605-615. PubMed ID: 28689357
[TBL] [Abstract][Full Text] [Related]
14. Objective comparison of lesion detectability in low and medium-energy collimator iodine-123 mIBG images using a channelized Hotelling observer.
Gregory RA; Murray I; Gear J; Aldridge MD; Levine D; Fowkes L; Waddington WA; Chua S; Flux G
Phys Med Biol; 2017 Jan; 62(1):17-30. PubMed ID: 27973344
[TBL] [Abstract][Full Text] [Related]
15. Correction of collimator-dependent differences in the heart-to-mediastinum ratio in
Inoue Y; Abe Y; Kikuchi K; Matsunaga K; Masuda R; Nishiyama K
J Nucl Cardiol; 2017 Oct; 24(5):1725-1736. PubMed ID: 27251143
[TBL] [Abstract][Full Text] [Related]
16. Application of a medium-energy collimator for I-131 imaging after ablation treatment of differentiated thyroid cancer.
Kobayashi M; Wakabayashi H; Kayano D; Konishi T; Kojima H; Yoneyama H; Okuda K; Tsushima H; Onoguchi M; Kawai K; Kinuya S
Ann Nucl Med; 2014 Jul; 28(6):551-8. PubMed ID: 24710758
[TBL] [Abstract][Full Text] [Related]
17. Primary, scatter, and penetration characterizations of parallel-hole and pinhole collimators for I-123 SPECT.
Könik A; Auer B; De Beenhouwer J; Kalluri K; Zeraatkar N; Furenlid LR; King MA
Phys Med Biol; 2019 Dec; 64(24):245001. PubMed ID: 31746783
[TBL] [Abstract][Full Text] [Related]
18. [Scatter Correction of Septal Penetration for
Yamanaga T; Katayama Y; Nakama S; Kakimi A; Nagahata T; Kishimoto K; Ichida T; Higashiyama S; Kawabe J; Shiomi S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2017; 73(10):1028-1038. PubMed ID: 29057774
[TBL] [Abstract][Full Text] [Related]
19. A European myocardial
Verschure DO; Poel E; Nakajima K; Okuda K; van Eck-Smit BLF; Somsen GA; Verberne HJ
J Nucl Cardiol; 2018 Aug; 25(4):1191-1197. PubMed ID: 28120154
[TBL] [Abstract][Full Text] [Related]
20. Optimal collimator choice for sequential iodine-123 and technetium-99m imaging.
Geeter FD; Franken PR; Defrise M; Andries H; Saelens E; Bossuyt A
Eur J Nucl Med; 1996 Jul; 23(7):768-74. PubMed ID: 8662115
[TBL] [Abstract][Full Text] [Related]