These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 17387452)

  • 1. Bernstein-Osypka stroke volume equation for impedance cardiography: citation correction.
    Bernstein DP
    Intensive Care Med; 2007 May; 33(5):923. PubMed ID: 17387452
    [No Abstract]   [Full Text] [Related]  

  • 2. Impedance cardiography. Importance of the equation and the electrode configuration.
    van der Meer BJ; Woltjer HH; Sousman AM; Schreuder WO; Bulder ER; Huybregts MA; de Vries PM
    Intensive Care Med; 1996 Oct; 22(10):1120-4. PubMed ID: 8923081
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.
    Woltjer HH; Bogaard HJ; Scheffer GJ; van der Spoel HI; Huybregts MA; de Vries PM
    Br J Anaesth; 1996 Dec; 77(6):748-52. PubMed ID: 9014628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution.
    Sherwood A; Carter LS; Murphy CA
    Aviat Space Environ Med; 1991 Feb; 62(2):116-22. PubMed ID: 2001207
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical evaluation of impedance cardiography.
    Goldstein DS; Cannon RO; Zimlichman R; Keiser HR
    Clin Physiol; 1986 Jun; 6(3):235-51. PubMed ID: 3087687
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients.
    Woltjer HH; Bogaard HJ; van der Spoel HI; de Vries PM
    Intensive Care Med; 1996 Aug; 22(8):766-71. PubMed ID: 8880245
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The dependability of noninvasive stroke volume measurements with impedance cardiography].
    Slany J; Mösslacher H; Kronik G; Schmoliner R
    Acta Med Austriaca; 1978; 5(4-5):118-21. PubMed ID: 756116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review.
    Newman DG; Callister R
    Aviat Space Environ Med; 1999 Aug; 70(8):780-9. PubMed ID: 10447052
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On-line computation of the stroke volume from the systolic stroke of the thoracic impedance. Part 1: method and automatic evaluation.
    Prestele K; Franetzki M
    Biomed Tech (Berl); 1980 Nov; 25(11):274-8. PubMed ID: 7459416
    [No Abstract]   [Full Text] [Related]  

  • 10. A review of impedance cardiography.
    Jensen L; Yakimets J; Teo KK
    Heart Lung; 1995; 24(3):183-93. PubMed ID: 7622392
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac performance measured by impedance cardiography and radionuclide angiography.
    Pedersen T
    Methods Find Exp Clin Pharmacol; 1984 Nov; 6(11):717-20. PubMed ID: 6530910
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of cardiac output using ensemble-averaged impedance cardiograms.
    Muzi M; Ebert TJ; Tristani FE; Jeutter DC; Barney JA; Smith JJ
    J Appl Physiol (1985); 1985 Jan; 58(1):200-5. PubMed ID: 3968011
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stroke volume equation for impedance cardiography.
    Bernstein DP; Lemmens HJ
    Med Biol Eng Comput; 2005 Jul; 43(4):443-50. PubMed ID: 16255425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: a comparison between thermodilution and impedance cardiography.
    Secher NJ; Arnsbo P; Andersen LH; Thomsen A
    Scand J Clin Lab Invest; 1979 Oct; 39(6):569-76. PubMed ID: 531485
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impedance cardiography in the measurement of cardiac output: studies in rabbits.
    Pappas CG; Wang X; Connolly RJ; Schwaitzberg SD
    J Surg Res; 1995 Oct; 59(4):504-10. PubMed ID: 7564325
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The technique of impedance cardiography.
    Woltjer HH; Bogaard HJ; de Vries PM
    Eur Heart J; 1997 Sep; 18(9):1396-403. PubMed ID: 9458444
    [No Abstract]   [Full Text] [Related]  

  • 17. Improvement in intracardiac impedance volumes by field extrapolation.
    Salo RW
    Eur Heart J; 1992 Nov; 13 Suppl E():35-9. PubMed ID: 1478207
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impedance cardiography in cardiac surgery patients: abnormal body weight gives unreliable cardiac output measurements.
    van der Meer BJ; de Vries JP; Schreuder WO; Bulder ER; Eysman L; de Vries PM
    Acta Anaesthesiol Scand; 1997 Jun; 41(6):708-12. PubMed ID: 9241329
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stroke volume in the dog: measurements by the impedance technique and thermodilution.
    Spinelli JC; Valentinuzzi ME
    Med Prog Technol; 1983; 10(1):45-53. PubMed ID: 6669146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise.
    Thomas SH
    Br J Clin Pharmacol; 1992 Dec; 34(6):467-76. PubMed ID: 1493078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.