These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 1738970)

  • 1. Implant holding power of the femoral head. A cadaver study of fracture screws.
    Benterud JG; Husby T; Graadahl O; Alho A
    Acta Orthop Scand; 1992 Feb; 63(1):47-9. PubMed ID: 1738970
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Screw fixation in the femoral head. Pull-out tests in cadavers.
    Iversen BF; Stürup J; Lyndrup P; Jensen NC; Therkilden MH
    Acta Orthop Scand; 1988 Dec; 59(6):655-7. PubMed ID: 3213451
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Holding power impaired in rheumatoid femoral heads. Cadaveric study of fracture fixation devices.
    Larsson S; Elloy M
    Acta Orthop Scand; 1990 Dec; 61(6):502-6. PubMed ID: 2281756
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Holding power of different screws in the femoral head. A study in human cadaver hips.
    Frandsen PA; Christoffersen H; Madsen T
    Acta Orthop Scand; 1984 Jun; 55(3):349-51. PubMed ID: 6741489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impaction bone-grafting increases the holding power of cancellous screws in the femoral head. A pull-out study in human cadaver hips.
    Lenzner A; Kaur I; Haviko T; Sõgel V; Gapejeva J; Ereline J; Pääsuke M
    Acta Orthop Scand; 1999 Feb; 70(1):25-8. PubMed ID: 10191743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Type of screw does not influence holding power in the femoral head: a cadaver study with shearing test.
    Jenny JY; Rapp E; Cordey J
    Acta Orthop Scand; 1999 Oct; 70(5):435-8. PubMed ID: 10622474
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of the role of the cancellous bone in generation of screw holding power at metaphysis.
    Harnroongroj T; Techataweewan A
    Clin Biomech (Bristol, Avon); 1999 Jun; 14(5):364-6. PubMed ID: 10521616
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density.
    Ab-Lazid R; Perilli E; Ryan MK; Costi JJ; Reynolds KJ
    J Mech Behav Biomed Mater; 2014 Dec; 40():354-361. PubMed ID: 25265033
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study.
    Konya MN; Verim Ö
    Balkan Med J; 2017 Sep; 34(5):425-431. PubMed ID: 28443571
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.
    Al-Munajjed AA; Hammer J; Mayr E; Nerlich M; Lenich A
    Stud Health Technol Inform; 2008; 133():1-10. PubMed ID: 18376008
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhancement of holding strength of cannulated screw supported with PMMA: a biomechanical study on femoral head [corrected].
    Zeynalov R; Ağır İ; Akgülle AH; Kocaoğlu B; Yalçın MS
    Eur J Orthop Surg Traumatol; 2015 Jul; 25(5):955-60. PubMed ID: 25208652
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Increasing bone screw anchoring in the femur head by cement administration via the implant--a biomechanical study].
    Kramer A; Angst M; Gasser B; Ganz R
    Z Orthop Ihre Grenzgeb; 2000; 138(5):464-9. PubMed ID: 11084750
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of implant design and bone density on maximum torque and holding power for femoral neck fracture devices.
    Eriksson F; Mattsson P; Larsson S
    Ann Chir Gynaecol; 2000; 89(2):119-23. PubMed ID: 10905678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound melted polymer sleeve for improved screw anchorage in trabecular bone--A novel screw augmentation technique.
    Schmoelz W; Mayr R; Schlottig F; Ivanovic N; Hörmann R; Goldhahn J
    Clin Biomech (Bristol, Avon); 2016 Mar; 33():79-83. PubMed ID: 26963706
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Local bone quality measurements correlates with maximum screw torque at the femoral diaphysis.
    McAndrew CM; Agarwalla A; Abraham AC; Feuchtbaum E; Ricci WM; Tang SY
    Clin Biomech (Bristol, Avon); 2018 Feb; 52():95-99. PubMed ID: 29407864
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Implant/bone constructs in femoral neck osteotomy. An autopsy study.
    Benterud JG; Alho A; Höiseth A
    Arch Orthop Trauma Surg; 1994; 113(2):97-100. PubMed ID: 8186057
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance.
    Heller JG; Estes BT; Zaouali M; Diop A
    J Bone Joint Surg Am; 1996 Sep; 78(9):1315-21. PubMed ID: 8816645
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stability of femoral neck osteotomies fixed by von Bahr screws or by compression hip screw.
    Engesaeter LB; Asserson O; Mølster A; Gjerdet NR; Langeland N
    Eur Surg Res; 1984; 16 Suppl 2():37-40. PubMed ID: 6723730
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Achievable accuracy of hip screw holding power estimation by insertion torque measurement.
    Erani P; Baleani M
    Clin Biomech (Bristol, Avon); 2018 Feb; 52():57-65. PubMed ID: 29360050
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
    Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.