These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 17392616)

  • 1. Intrathoracic impedance monitoring for early detection of impending heart failure decompensation.
    Abraham WT
    Congest Heart Fail; 2007; 13(2):113-5. PubMed ID: 17392616
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization.
    Yu CM; Wang L; Chau E; Chan RH; Kong SL; Tang MO; Christensen J; Stadler RW; Lau CP
    Circulation; 2005 Aug; 112(6):841-8. PubMed ID: 16061743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New approaches to monitoring heart failure before symptoms appear.
    Abraham WT
    Rev Cardiovasc Med; 2006; 7 Suppl 1():S33-41. PubMed ID: 16955058
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial.
    Conraads VM; Tavazzi L; Santini M; Oliva F; Gerritse B; Yu CM; Cowie MR
    Eur Heart J; 2011 Sep; 32(18):2266-73. PubMed ID: 21362703
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rationale and design of a prospective trial to assess the sensitivity and positive predictive value of implantable intrathoracic impedance monitoring in the prediction of heart failure hospitalizations: the SENSE-HF study.
    Cowie MR; Conraads V; Tavazzi L; Yu CM;
    J Card Fail; 2009 Jun; 15(5):394-400. PubMed ID: 19477399
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Device monitoring of intrathoracic impedance: clinical observations from a patient registry.
    Andriulli J
    Am J Cardiol; 2007 May; 99(10A):23G-8G. PubMed ID: 17512419
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Device monitoring of heart failure in cardiac resynchronization therapy device recipients: a single-center experience with a novel multivector impedance monitoring system.
    Forleo GB; Panattoni G; Schirripa V; Papavasileiou LP; Della Rocca DG; Politano A; Ticconi F; Biscione C; Sergi D; Di Molfetta A; Santini L; Capria A; Romeo F
    J Cardiovasc Med (Hagerstown); 2013 Oct; 14(10):726-32. PubMed ID: 23996011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thoracic impedance as a therapeutic marker of acute decompensated heart failure.
    Aizawa Y; Takatsuki S; Kashimura S; Katsumata Y; Nishiyama T; Kimura T; Nishiyama N; Tanimoto Y; Tanimoto K; Fukuda Y; Sato T; Ogawa S; Fukuda K
    Int J Cardiol; 2014 Jul; 174(3):840-2. PubMed ID: 24801075
    [No Abstract]   [Full Text] [Related]  

  • 9. Fundamentals of intrathoracic impedance monitoring in heart failure.
    Wang L
    Am J Cardiol; 2007 May; 99(10A):3G-10G. PubMed ID: 17512421
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intrathoracic impedance and ultrasound lung comets in heart failure deterioration monitoring.
    Maines M; Catanzariti D; Angheben C; Valsecchi S; Comisso J; Vergara G
    Pacing Clin Electrophysiol; 2011 Aug; 34(8):968-74. PubMed ID: 21477028
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of different device-based intrathoracic impedance vectors for detection of heart failure events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring study).
    Heist EK; Herre JM; Binkley PF; Van Bakel AB; Porterfield JG; Porterfield LM; Qu F; Turkel M; Pavri BB;
    Am J Cardiol; 2014 Oct; 114(8):1249-56. PubMed ID: 25150135
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure.
    Vollmann D; Nägele H; Schauerte P; Wiegand U; Butter C; Zanotto G; Quesada A; Guthmann A; Hill MR; Lamp B;
    Eur Heart J; 2007 Aug; 28(15):1835-40. PubMed ID: 17309902
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intrathoracic impedance vs daily weight monitoring for predicting worsening heart failure events: results of the Fluid Accumulation Status Trial (FAST).
    Abraham WT; Compton S; Haas G; Foreman B; Canby RC; Fishel R; McRae S; Toledo GB; Sarkar S; Hettrick DA;
    Congest Heart Fail; 2011; 17(2):51-5. PubMed ID: 21449992
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Integrating device-based monitoring into clinical practice: insights from a large heart failure clinic.
    Small RS
    Am J Cardiol; 2007 May; 99(10A):17G-22G. PubMed ID: 17512418
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intracardiac impedance after cardiac resynchronization therapy is a novel predictor for worsening of heart failure.
    Suzuki H; Nodera M; Kamioka M; Kaneshiro T; Kamiyama Y; Takeishi Y
    Heart Vessels; 2017 Aug; 32(8):926-931. PubMed ID: 28181011
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration.
    Maines M; Catanzariti D; Cirrincione C; Valsecchi S; Comisso J; Vergara G
    Europace; 2010 May; 12(5):680-5. PubMed ID: 20047927
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of thoracic impedance trends for implant-based remote monitoring in heart failure patients - Results from the (J-)HomeCARE-II Study.
    Maier SKG; Paule S; Jung W; Koller M; Ventura R; Quesada A; Bordachar P; García-Fernández FJ; Schumacher B; Lobitz N; Takizawa K; Ando K; Adachi K; Shoda M
    J Electrocardiol; 2019; 53():100-108. PubMed ID: 30739055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure.
    Vanderheyden M; Houben R; Verstreken S; Ståhlberg M; Reiters P; Kessels R; Braunschweig F
    Circ Heart Fail; 2010 May; 3(3):370-7. PubMed ID: 20197559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intrathoracic impedance monitoring detecting pneumonia.
    Barth C; Kindermann I; Mahfoud F; Buob A; Böhm M
    Clin Res Cardiol; 2010 May; 99(5):333-5. PubMed ID: 20165857
    [No Abstract]   [Full Text] [Related]  

  • 20. Measurement of thoracic fluid content in heart failure: the role of impedance cardiography.
    Folan L; Funk M
    AACN Adv Crit Care; 2008; 19(1):47-55. PubMed ID: 18418105
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.