BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

908 related articles for article (PubMed ID: 17395995)

  • 21. ECG signal denoising and baseline wander correction based on the empirical mode decomposition.
    Blanco-Velasco M; Weng B; Barner KE
    Comput Biol Med; 2008 Jan; 38(1):1-13. PubMed ID: 17669389
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram.
    De Clercq W; Vergult A; Vanrumste B; Van Paesschen W; Van Huffel S
    IEEE Trans Biomed Eng; 2006 Dec; 53(12 Pt 1):2583-7. PubMed ID: 17153216
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Artifact reduction in magnetogastrography using fast independent component analysis.
    Irimia A; Bradshaw LA
    Physiol Meas; 2005 Dec; 26(6):1059-73. PubMed ID: 16311453
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Denoising of surface EMG with a modified Wiener filtering approach.
    Aschero G; Gizdulich P
    J Electromyogr Kinesiol; 2010 Apr; 20(2):366-73. PubMed ID: 19278870
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators.
    Jekova I; Krasteva V
    Physiol Meas; 2005 Dec; 26(6):987-1003. PubMed ID: 16311447
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accurate real-time feedback of surface EMG during fMRI.
    Ganesh G; Franklin DW; Gassert R; Imamizu H; Kawato M
    J Neurophysiol; 2007 Jan; 97(1):912-20. PubMed ID: 17005612
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Power-line interference detection and suppression in ECG signal processing.
    Lin YD; Hu YH
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):354-7. PubMed ID: 18232382
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Removal of the electrocardiogram signal from surface EMG recordings using non-linearly scaled wavelets.
    von Tscharner V; Eskofier B; Federolf P
    J Electromyogr Kinesiol; 2011 Aug; 21(4):683-8. PubMed ID: 21470876
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Noise reduction based on ICA decomposition and wavelet transform for the extraction of motor unit action potentials.
    Ren X; Yan Z; Wang Z; Hu X
    J Neurosci Methods; 2006 Dec; 158(2):313-22. PubMed ID: 16831466
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of adaptive/nonadaptive filtering and wavelet transform techniques for noise reduction in EMG mobile acquisition equipment.
    Ortolan RL; Mori RN; Pereira RR; Cabral CM; Pereira JC; Cliquet AJ
    IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):60-9. PubMed ID: 12797727
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stimulation artifact in surface EMG signal: effect of the stimulation waveform, detection system, and current amplitude using hybrid stimulation technique.
    Mandrile F; Farina D; Pozzo M; Merletti R
    IEEE Trans Neural Syst Rehabil Eng; 2003 Dec; 11(4):407-15. PubMed ID: 14960117
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Relevance of motion artifact in electromyography recordings during vibration treatment.
    Fratini A; Cesarelli M; Bifulco P; Romano M
    J Electromyogr Kinesiol; 2009 Aug; 19(4):710-8. PubMed ID: 18495492
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A low-distortion filter method to reject muscle noise in multi-lead electrocardiogram systems.
    Wei D; Harasawa E; Hosaka H
    Front Med Biol Eng; 1999; 9(4):315-30. PubMed ID: 10718669
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Less is more: high pass filtering, to remove up to 99% of the surface EMG signal power, improves EMG-based biceps brachii muscle force estimates.
    Potvin JR; Brown SH
    J Electromyogr Kinesiol; 2004 Jun; 14(3):389-99. PubMed ID: 15094152
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Can standard surface EMG processing parameters be used to estimate motor unit global firing rate?
    Zhou P; Rymer WZ
    J Neural Eng; 2004 Jun; 1(2):99-110. PubMed ID: 15876628
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optimized wavelets for blind separation of nonstationary surface myoelectric signals.
    Farina D; Lucas MF; Doncarli C
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):78-86. PubMed ID: 18232349
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A single-lead ECG enhancement algorithm using a regularized data-driven filter.
    Hu X; Nenov V
    IEEE Trans Biomed Eng; 2006 Feb; 53(2):347-51. PubMed ID: 16485766
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals.
    Rheinberger K; Steinberger T; Unterkofler K; Baubin M; Klotz A; Amann A
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):130-7. PubMed ID: 18232354
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Bioelectric signal detrending using smoothness prior approach.
    Zhang F; Chen S; Zhang H; Zhang X; Li G
    Med Eng Phys; 2014 Aug; 36(8):1007-13. PubMed ID: 24894030
    [TBL] [Abstract][Full Text] [Related]  

  • 40. ECG artifact cancellation in surface EMG signals by fractional order calculus application.
    Miljković N; Popović N; Djordjević O; Konstantinović L; Šekara TB
    Comput Methods Programs Biomed; 2017 Mar; 140():259-264. PubMed ID: 28254082
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 46.