BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 17396693)

  • 1. Computerized detection and measurement of drusen in age-related macular degeneration.
    Friberg TR; Huang L; Palaiou M; Bremer R
    Ophthalmic Surg Lasers Imaging; 2007; 38(2):126-34. PubMed ID: 17396693
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computer-assisted, interactive fundus image processing for macular drusen quantitation.
    Shin DS; Javornik NB; Berger JW
    Ophthalmology; 1999 Jun; 106(6):1119-25. PubMed ID: 10366080
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Drusen analysis in a human-machine synergistic framework.
    Smith RT; Sohrab MA; Pumariega NM; Mathur K; Haans R; Blonska A; Uy K; Despriet D; Klaver C
    Arch Ophthalmol; 2011 Jan; 129(1):40-7. PubMed ID: 21220627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic drusen quantification and risk assessment of age-related macular degeneration on color fundus images.
    van Grinsven MJ; Lechanteur YT; van de Ven JP; van Ginneken B; Hoyng CB; Theelen T; Sánchez CI
    Invest Ophthalmol Vis Sci; 2013 Apr; 54(4):3019-27. PubMed ID: 23572106
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated detection of age-related macular degeneration in color fundus photography: a systematic review.
    Pead E; Megaw R; Cameron J; Fleming A; Dhillon B; Trucco E; MacGillivray T
    Surv Ophthalmol; 2019; 64(4):498-511. PubMed ID: 30772363
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Quantitative and spatial analysis in image processing: study of drusen distribution from the foveal center in age-related macular degeneration].
    Barthes A; Conrath J; Ridings B
    J Fr Ophtalmol; 2005 Mar; 28(3):298-302. PubMed ID: 15883495
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated drusen detection in retinal images using analytical modelling algorithms.
    Mora AD; Vieira PM; Manivannan A; Fonseca JM
    Biomed Eng Online; 2011 Jul; 10():59. PubMed ID: 21749717
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of nonmydriatic digitized video fundus images with standard 35-mm slides to screen for and identify specific lesions of age-related macular degeneration.
    Lim JI; Labree L; Nichols T; Cardenas I
    Retina; 2002 Feb; 22(1):59-64. PubMed ID: 11884880
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated detection of macular drusen using geometric background leveling and threshold selection.
    Smith RT; Chan JK; Nagasaki T; Ahmad UF; Barbazetto I; Sparrow J; Figueroa M; Merriam J
    Arch Ophthalmol; 2005 Feb; 123(2):200-6. PubMed ID: 15710816
    [TBL] [Abstract][Full Text] [Related]  

  • 10. What is lost by digitizing stereoscopic fundus color slides for macular grading in age-related maculopathy and degeneration?
    Scholl HP; Dandekar SS; Peto T; Bunce C; Xing W; Jenkins S; Bird AC
    Ophthalmology; 2004 Jan; 111(1):125-32. PubMed ID: 14711724
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Drusen quantification for early identification of age related macular degeneration (AMD) using color fundus imaging.
    Bhuiyan A; Karmakar C; Xiao D; Ramamohanarao K; Kanagasingam Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():7392-5. PubMed ID: 24111453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated assessment of drusen using three-dimensional spectral-domain optical coherence tomography.
    Iwama D; Hangai M; Ooto S; Sakamoto A; Nakanishi H; Fujimura T; Domalpally A; Danis RP; Yoshimura N
    Invest Ophthalmol Vis Sci; 2012 Mar; 53(3):1576-83. PubMed ID: 22297491
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method of drusen measurement based on the geometry of fundus reflectance.
    Smith RT; Nagasaki T; Sparrow JR; Barbazetto I; Klaver CC; Chan JK
    Biomed Eng Online; 2003 Apr; 2():10. PubMed ID: 12740042
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detection of drusen and early signs of age-related maculopathy using a nonmydriatic camera and a standard fundus camera.
    Klein R; Meuer SM; Moss SE; Klein BE
    Ophthalmology; 1992 Nov; 99(11):1686-92. PubMed ID: 1454343
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of drusen in the fellow eye of Japanese patients with age-related macular degeneration using scanning laser ophthalmoscopy.
    Ishiko S; Akiba J; Horikawa Y; Yoshida A
    Ophthalmology; 2002 Nov; 109(11):2165-9. PubMed ID: 12414434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated Segmentation Methods of Drusen to Diagnose Age-Related Macular Degeneration Screening in Retinal Images.
    Kim YJ; Kim KG
    Comput Math Methods Med; 2018; 2018():6084798. PubMed ID: 29721037
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Age-Related Eye Disease Study system for classifying age-related macular degeneration from stereoscopic color fundus photographs: the Age-Related Eye Disease Study Report Number 6.
    Age-Related Eye Disease Study Research Group
    Am J Ophthalmol; 2001 Nov; 132(5):668-81. PubMed ID: 11704028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An interinstitutional comparative study and validation of computer aided drusen quantification.
    Sivagnanavel V; Smith RT; Lau GB; Chan J; Donaldson C; Chong NV
    Br J Ophthalmol; 2005 May; 89(5):554-7. PubMed ID: 15834083
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Statistical characterization and segmentation of drusen in fundus images.
    Santos-Villalobos H; Karnowski TP; Aykac D; Giancardo L; Li Y; Nichols T; Tobin KW; Chaum E
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():6236-41. PubMed ID: 22255764
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection and segmentation of drusen deposits on human retina: potential in the diagnosis of age-related macular degeneration.
    Rapantzikos K; Zervakis M; Balas K
    Med Image Anal; 2003 Mar; 7(1):95-108. PubMed ID: 12467724
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.