21. [Cold tap water as a source of fatal nosocomial pneumonia due to Legionella pneumophila in a rehabilitation center]. Hoebe CJ; Cluitmans JJ; Wagenvoort JH; van Leeuwen WJ; Bilkert-Mooiman MA Ned Tijdschr Geneeskd; 1999 May; 143(20):1041-5. PubMed ID: 10368731 [TBL] [Abstract][Full Text] [Related]
22. Parameters predictive of Legionella contamination in hot water systems: association with trace elements and heterotrophic plate counts. Bargellini A; Marchesi I; Righi E; Ferrari A; Cencetti S; Borella P; Rovesti S Water Res; 2011 Mar; 45(6):2315-21. PubMed ID: 21316728 [TBL] [Abstract][Full Text] [Related]
23. [Detection of legionellae in thermal water]. Schaffler-Dullnig K; Reinthaler FF; Marth E Zentralbl Hyg Umweltmed; 1992 Feb; 192(5):473-8. PubMed ID: 1554406 [TBL] [Abstract][Full Text] [Related]
24. [Occurrence of bacteria from the Legionella genus in cooling water systems]. Matuszewska R; Krogulska B Rocz Panstw Zakl Hig; 2008; 59(4):445-54. PubMed ID: 19227256 [TBL] [Abstract][Full Text] [Related]
25. Legionella pollution in cooling tower water of air-conditioning systems in Shanghai, China. Lin H; Xu B; Chen Y; Wang W J Appl Microbiol; 2009 Feb; 106(2):606-12. PubMed ID: 19120608 [TBL] [Abstract][Full Text] [Related]
26. Resistance of Legionella to disinfection in hot water distribution systems. Saby S; Vidal A; Suty H Water Sci Technol; 2005; 52(8):15-28. PubMed ID: 16312947 [TBL] [Abstract][Full Text] [Related]
27. Legionella species colonization in cooling towers: risk factors and assessment of control measures. Mouchtouri VA; Goutziana G; Kremastinou J; Hadjichristodoulou C Am J Infect Control; 2010 Feb; 38(1):50-5. PubMed ID: 19699013 [TBL] [Abstract][Full Text] [Related]
28. Risk factors for contamination of hotel water distribution systems by Legionella species. Mouchtouri V; Velonakis E; Tsakalof A; Kapoula C; Goutziana G; Vatopoulos A; Kremastinou J; Hadjichristodoulou C Appl Environ Microbiol; 2007 Mar; 73(5):1489-92. PubMed ID: 17261527 [TBL] [Abstract][Full Text] [Related]
29. Bacterial colonization and occurrence of Legionella pneumophila in warm and cold water, in faucet aerators, and in drains of hospitals. Botzenhart K; Heizmann W; Sedaghat S; Heeg P; Hahn T Zentralbl Bakteriol Mikrobiol Hyg B Umwelthyg Krankenhaushyg Arbeitshyg Prav Med; 1986 Dec; 183(1):79-85. PubMed ID: 3107260 [TBL] [Abstract][Full Text] [Related]
30. Isolation and identification of Legionella spp. from hot spring water in Algeria by culture and molecular methods. Boilattabi N; Barrassi L; Bouanane-Darenfed A; La Scola B J Appl Microbiol; 2021 Apr; 130(4):1394-1400. PubMed ID: 32985039 [TBL] [Abstract][Full Text] [Related]
31. Assessment of Legionella pneumophila in recreational spring water with quantitative PCR (Taqman) assay. Shen SM; Chou MY; Hsu BM; Ji WT; Hsu TK; Tsai HF; Huang YL; Chiu YC; Kao ES; Kao PM; Fan CW Pathog Glob Health; 2015 Jul; 109(5):236-41. PubMed ID: 26184706 [TBL] [Abstract][Full Text] [Related]
32. Occurrence and parameters of frequency of Legionella in warm water systems of hospitals and hotels in Lower Saxony. Habicht W; Müller HE Zentralbl Bakteriol Mikrobiol Hyg B Umwelthyg Krankenhaushyg Arbeitshyg Prav Med; 1988 Mar; 186(1):79-88. PubMed ID: 3134774 [TBL] [Abstract][Full Text] [Related]
33. Presence of Legionella spp. in thermal springs of the Campania region of south Italy. Sommese L; Scarfogliero P; Vitiello M; Catalanotti P; Galdiero E New Microbiol; 1996 Oct; 19(4):315-20. PubMed ID: 8914132 [TBL] [Abstract][Full Text] [Related]
34. Prevalence of Legionella pneumophila serogroup 1 in water distribution systems in Izmir province of Turkey. Uzel A; Uçar F; Hameş-Kocabaş EE APMIS; 2005 Oct; 113(10):664-9. PubMed ID: 16309424 [TBL] [Abstract][Full Text] [Related]
35. Effective environmental sampling strategies for monitoring Legionella spp contamination in hot water systems. Ditommaso S; Giacomuzzi M; Gentile M; Moiraghi AR; Zotti CM Am J Infect Control; 2010 Jun; 38(5):344-9. PubMed ID: 20083326 [TBL] [Abstract][Full Text] [Related]
36. Prevalence of Legionella species, serogroups, and monoclonal subgroups in hot water systems in south-eastern Germany. Lück PC; Leupold I; Hlawitschka M; Helbig JH; Carmienke I; Jatzwauk L; Guderitz T Zentralbl Hyg Umweltmed; 1993 Feb; 193(5):450-60. PubMed ID: 8476497 [TBL] [Abstract][Full Text] [Related]
37. Surveillance and evaluation of the infection risk of free-living amoebae and Legionella in different aquatic environments. Ji WT; Hsu BM; Chang TY; Hsu TK; Kao PM; Huang KH; Tsai SF; Huang YL; Fan CW Sci Total Environ; 2014 Nov; 499():212-9. PubMed ID: 25192927 [TBL] [Abstract][Full Text] [Related]
38. Legionella in clinical specimens and hospital water supply facilities: molecular detection and genotyping of the isolates. Qasem JA; Mustafa AS; Khan ZU Med Princ Pract; 2008; 17(1):49-55. PubMed ID: 18059101 [TBL] [Abstract][Full Text] [Related]
39. Isolation and identification of Acanthamoeba from Taiwan spring recreation areas using culture enrichment combined with PCR. Huang SW; Hsu BM Acta Trop; 2010 Sep; 115(3):282-7. PubMed ID: 20434423 [TBL] [Abstract][Full Text] [Related]
40. [Contamination status and molecular biological characteristics of Legionella in cooling water samples from different places in Wuxi city]. Zhang Q; Chen R; Xiao Y; Liu B; Qin T; Shao ZJ; Zhou WJ Zhonghua Yu Fang Yi Xue Za Zhi; 2012 Mar; 46(3):264-8. PubMed ID: 22800600 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]