41. Colonization of Legionella species in hotel water systems in Turkey. Erdogan H; Arslan H J Travel Med; 2007; 14(6):369-73. PubMed ID: 17995531 [TBL] [Abstract][Full Text] [Related]
42. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water. Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074 [TBL] [Abstract][Full Text] [Related]
43. [The control of the presence of Legionella in contaminated hot water systems]. Seidel K; Grohmann A Schriftenr Ver Wasser Boden Lufthyg; 1987; 72():91-102. PubMed ID: 3685900 [No Abstract] [Full Text] [Related]
44. [Study on the distributive regulation of Legionella pneumophila in different water]. Liu H; Hou C; Xu Y; Huang A; Chen X Wei Sheng Yan Jiu; 2004 Jul; 33(4):416-9. PubMed ID: 15461262 [TBL] [Abstract][Full Text] [Related]
45. Evaluation of the effectiveness of the Pastormaster method for disinfection of legionella in a hospital water distribution system. Peiró Callizo EF; Sierra JD; Pombo JM; Baquedano CE; Huerta BP J Hosp Infect; 2005 Jun; 60(2):150-8. PubMed ID: 15866014 [TBL] [Abstract][Full Text] [Related]
46. Activity of bacteria in water of hot springs from Southern and Central Kamchatskaya geothermal provinces, Kamchatka Peninsula, Russia. Belkova NL; Tazaki K; Zakharova JR; Parfenova VV Microbiol Res; 2007; 162(2):99-107. PubMed ID: 16546359 [TBL] [Abstract][Full Text] [Related]
47. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital. Darelid J; Löfgren S; Malmvall BE J Hosp Infect; 2002 Mar; 50(3):213-9. PubMed ID: 11886198 [TBL] [Abstract][Full Text] [Related]
48. [Biogeochemical processes in the algal-bacterial mats of the Urinskii alkaline hot spring]. Brianskaia AV; Namsaraev ZB; Kalashnikova OM; Barkhutova DD; Namsaraev BB; Gorlenko VM Mikrobiologiia; 2006; 75(5):702-12. PubMed ID: 17091594 [TBL] [Abstract][Full Text] [Related]
49. Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene. van der Kooij D; Veenendaal HR; Scheffer WJ Water Res; 2005 Aug; 39(13):2789-98. PubMed ID: 16019051 [TBL] [Abstract][Full Text] [Related]
50. [Antimicrobial ceramic for killing Legionella pneumophila in hot spring waters]. Sasahara T; Okuda S; Kikuno R; Satoh Y; Sekiguchi T; Takayama Y; Inoue M Kansenshogaku Zasshi; 2005 Mar; 79(3):157-60. PubMed ID: 15977555 [TBL] [Abstract][Full Text] [Related]
51. [Sanitizing a hospital hot water system contaminated with Legionella pneumophila]. Schulze-Röbbecke R; Jung KD; Pullmann H; Hundgeburth J Zentralbl Hyg Umweltmed; 1990 May; 190(1-2):84-100. PubMed ID: 2118357 [TBL] [Abstract][Full Text] [Related]
52. [Legionellas in domestic warm water--effects on the health of residents]. Heudorf U; Hentschel W; Hoffmann M; Lück C; Schubert R Gesundheitswesen; 2001 May; 63(5):326-34. PubMed ID: 11441676 [TBL] [Abstract][Full Text] [Related]
53. Colonization of a therapeutic spa with Legionella spp: a public health issue. Costa J; da Costa MS; Veríssimo A Res Microbiol; 2010; 161(1):18-25. PubMed ID: 20004717 [TBL] [Abstract][Full Text] [Related]
54. Experimental studies of detection and processing of Legionella spp. in public drinking water supplies. Müller HE Zentralbl Bakteriol Mikrobiol Hyg B Umwelthyg Krankenhaushyg Arbeitshyg Prav Med; 1988 Mar; 186(1):73-8. PubMed ID: 3134773 [TBL] [Abstract][Full Text] [Related]
55. Effects of chlorination and heat disinfection on long-term starved Legionella pneumophila in warm water. Chang CW; Hwang YH; Cheng WY; Chang CP J Appl Microbiol; 2007 Jun; 102(6):1636-44. PubMed ID: 17578429 [TBL] [Abstract][Full Text] [Related]
56. [Research on the procedure for recovery and species identification of Legionella from surface environmental water]. Qu PH; Yin YB; Hu ZH; Zhu QY; Song YJ; Yang RF; Liu YL; Li P Zhonghua Yu Fang Yi Xue Za Zhi; 2008 Sep; 42(9):653-7. PubMed ID: 19175175 [TBL] [Abstract][Full Text] [Related]
57. Association between Legionella pneumophila and amoebae in water. Henke M; Seidel KM Isr J Med Sci; 1986 Sep; 22(9):690-5. PubMed ID: 3793452 [TBL] [Abstract][Full Text] [Related]
58. [Legionella contamination in the hospital environment: monitoring of the hot water distribution systems of three hospitals in Catania (Italy)]. Pignato S; Coniglio MA; Faro G; Cantaro P; Carini SA; Mangano G; Cunsolo R; Coco G; Giammanco G Ig Sanita Pubbl; 2006; 62(6):635-52. PubMed ID: 17256019 [TBL] [Abstract][Full Text] [Related]
59. Field testing hot water temperature reduction as an energy-saving measure--does the Legionella presence change in a clinic's plumbing system? Völker S; Kistemann T Environ Technol; 2015; 36(13-16):2138-47. PubMed ID: 25708236 [TBL] [Abstract][Full Text] [Related]
60. Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species. Ditommaso S; Biasin C; Giacomuzzi M; Zotti CM; Cavanna A; Ruggenini Moiraghi A Infect Control Hosp Epidemiol; 2005 May; 26(5):490-3. PubMed ID: 15954489 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]