289 related articles for article (PubMed ID: 17406444)
1. Quality assurance for polychromatic flow cytometry.
Perfetto SP; Ambrozak D; Nguyen R; Chattopadhyay P; Roederer M
Nat Protoc; 2006; 1(3):1522-30. PubMed ID: 17406444
[TBL] [Abstract][Full Text] [Related]
2. Quality assurance for polychromatic flow cytometry using a suite of calibration beads.
Perfetto SP; Ambrozak D; Nguyen R; Chattopadhyay PK; Roederer M
Nat Protoc; 2012 Dec; 7(12):2067-79. PubMed ID: 23138348
[TBL] [Abstract][Full Text] [Related]
3. Fundamental flow cytometer properties governing sensitivity and resolution.
Wood JC
Cytometry; 1998 Oct; 33(2):260-6. PubMed ID: 9773889
[TBL] [Abstract][Full Text] [Related]
4. Resolution of dimly fluorescent particles: a practical measure of fluorescence sensitivity.
Chase ES; Hoffman RA
Cytometry; 1998 Oct; 33(2):267-79. PubMed ID: 9773890
[TBL] [Abstract][Full Text] [Related]
5. Photomultiplier voltage setting: possible important source of variability in molecular equivalents of soluble fluorochrome (MESF) calculation?
Rigolin GM; Lanza F; Castoldi G
Cytometry; 1995 Aug; 20(4):362-8. PubMed ID: 7587725
[TBL] [Abstract][Full Text] [Related]
6. Evaluating fluorescence sensitivity on flow cytometers: an overview.
Wood JC; Hoffman RA
Cytometry; 1998 Oct; 33(2):256-9. PubMed ID: 9773888
[TBL] [Abstract][Full Text] [Related]
7. A modular detector for flow cytometric multicolor fluorescence measurements.
Steinkamp JA; Habbersett RC; Stewart CC
Cytometry; 1987 Jul; 8(4):353-65. PubMed ID: 3622158
[TBL] [Abstract][Full Text] [Related]
8. Standardization, calibration, and control in flow cytometry.
Hoffman RA
Curr Protoc Cytom; 2005 May; Chapter 1():Unit 1.3. PubMed ID: 18770811
[TBL] [Abstract][Full Text] [Related]
9. Classification and properties of 64 multiplexed microsphere sets.
Kettman JR; Davies T; Chandler D; Oliver KG; Fulton RJ
Cytometry; 1998 Oct; 33(2):234-43. PubMed ID: 9773885
[TBL] [Abstract][Full Text] [Related]
10. Determination of background, signal-to-noise, and dynamic range of a flow cytometer: A novel practical method for instrument characterization and standardization.
Giesecke C; Feher K; von Volkmann K; Kirsch J; Radbruch A; Kaiser T
Cytometry A; 2017 Nov; 91(11):1104-1114. PubMed ID: 28960720
[TBL] [Abstract][Full Text] [Related]
11. Standardizing flow cytometry: construction of a standardized fluorescence calibration plot using matching spectral calibrators.
Schwartz A; Fernández Repollet E; Vogt R; Gratama JW
Cytometry; 1996 Mar; 26(1):22-31. PubMed ID: 8809477
[TBL] [Abstract][Full Text] [Related]
12. Intracellular cytokine optimization and standard operating procedure.
Lamoreaux L; Roederer M; Koup R
Nat Protoc; 2006; 1(3):1507-16. PubMed ID: 17406442
[TBL] [Abstract][Full Text] [Related]
13. Model system evaluating fluorescein-labeled microbeads as internal standards to calibrate fluorescence intensity on flow cytometers.
Vogt RF; Cross GD; Henderson LO; Phillips DL
Cytometry; 1989 May; 10(3):294-302. PubMed ID: 2714113
[TBL] [Abstract][Full Text] [Related]
14. Violet laser diodes in flow cytometry: an update.
Telford W; Kapoor V; Jackson J; Burgess W; Buller G; Hawley T; Hawley R
Cytometry A; 2006 Nov; 69(11):1153-60. PubMed ID: 17051581
[TBL] [Abstract][Full Text] [Related]
15. Flow cytometer in the infrared: inexpensive modifications to a commercial instrument.
Stewart CC; Woodring ML; Podniesinski E; Gray B
Cytometry A; 2005 Oct; 67(2):104-11. PubMed ID: 16163692
[TBL] [Abstract][Full Text] [Related]
16. Sensitivity measurement and compensation in spectral imaging.
Ortyn WE; Hall BE; George TC; Frost K; Basiji DA; Perry DJ; Zimmerman CA; Coder D; Morrissey PJ
Cytometry A; 2006 Aug; 69(8):852-62. PubMed ID: 16969805
[TBL] [Abstract][Full Text] [Related]
17. Flow cytometry and FISH to measure the average length of telomeres (flow FISH).
Baerlocher GM; Vulto I; de Jong G; Lansdorp PM
Nat Protoc; 2006; 1(5):2365-76. PubMed ID: 17406480
[TBL] [Abstract][Full Text] [Related]
18. Observation of single-cell fluorescence spectra in laser flow cytometry.
Gauci MR; Vesey G; Narai J; Veal D; Williams KL; Piper JA
Cytometry; 1996 Dec; 25(4):388-93. PubMed ID: 8946147
[TBL] [Abstract][Full Text] [Related]
19. Toward quantitative fluorescence measurements with multicolor flow cytometry.
Wang L; Gaigalas AK; Marti G; Abbasi F; Hoffman RA
Cytometry A; 2008 Apr; 73(4):279-88. PubMed ID: 18163471
[TBL] [Abstract][Full Text] [Related]
20. Immunofluorescence: quantitative considerations.
Haaijman JJ
Acta Histochem Suppl; 1988; 35():77-83. PubMed ID: 3138723
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]