These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. [Intermediate and long-term follow-up evaluation of posterior dynamic lumbar stabilization in lumbar degenerative disease]. Xu L; Yu X; Bi LY; Liu GZ; Li PY; Qu Y; Jiao Y Zhonghua Wai Ke Za Zhi; 2012 Sep; 50(9):792-6. PubMed ID: 23157953 [TBL] [Abstract][Full Text] [Related]
5. The Lumbar I/F Cage for posterior lumbar interbody fusion with the variable screw placement system: 10-year results of a Food and Drug Administration clinical trial. Brantigan JW; Neidre A; Toohey JS Spine J; 2004; 4(6):681-8. PubMed ID: 15541703 [TBL] [Abstract][Full Text] [Related]
6. [The DIAM spinal stabilisation system to treat degenerative disease of the lumbosacral spine]. Hrabálek L; Machác J; Vaverka M Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):417-23. PubMed ID: 19912707 [TBL] [Abstract][Full Text] [Related]
7. Prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: five-year follow-up. Guyer RD; McAfee PC; Banco RJ; Bitan FD; Cappuccino A; Geisler FH; Hochschuler SH; Holt RT; Jenis LG; Majd ME; Regan JJ; Tromanhauser SG; Wong DC; Blumenthal SL Spine J; 2009 May; 9(5):374-86. PubMed ID: 18805066 [TBL] [Abstract][Full Text] [Related]
8. [Retrospective study of complication of interspinous implants for degenerative lumbar disease]. Sun HL; Li CD; Liu XY; Yi XD; Lin JR; Liu H; Lu HL; Li H; Yu ZR Zhonghua Wai Ke Za Zhi; 2013 Jan; 51(1):35-9. PubMed ID: 23578425 [TBL] [Abstract][Full Text] [Related]
9. Effect of spacer diameter of the Dynesys dynamic stabilization system on the biomechanics of the lumbar spine: a finite element analysis. Shih SL; Chen CS; Lin HM; Huang LY; Liu CL; Huang CH; Cheng CK J Spinal Disord Tech; 2012 Jul; 25(5):E140-9. PubMed ID: 22744611 [TBL] [Abstract][Full Text] [Related]
10. Failure of the Wallis interspinous implant to lower the incidence of recurrent lumbar disc herniations in patients undergoing primary disc excision. Floman Y; Millgram MA; Smorgick Y; Rand N; Ashkenazi E J Spinal Disord Tech; 2007 Jul; 20(5):337-41. PubMed ID: 17607096 [TBL] [Abstract][Full Text] [Related]
11. Biomechanical comparison of an interspinous device and a rigid stabilization on lumbar adjacent segment range of motion. Hartmann F; Dietz SO; Kuhn S; Hely H; Rommens PM; Gercek E Acta Chir Orthop Traumatol Cech; 2011; 78(5):404-9. PubMed ID: 22094153 [TBL] [Abstract][Full Text] [Related]