222 related articles for article (PubMed ID: 1742833)
1. Measurement of cardiac output--transtracheal Doppler versus thermodilution.
Froese N; Friesen R
Can J Anaesth; 1991 Oct; 38(7):931-4. PubMed ID: 1742833
[TBL] [Abstract][Full Text] [Related]
2. [Intraoperative cardiac output monitoring by the transtracheal Doppler method].
Yoshitake S; Taniguchi K; Iwasaka H; Miyakawa H; Oda S; Honda N
Masui; 1990 Sep; 39(9):1138-41. PubMed ID: 2246803
[TBL] [Abstract][Full Text] [Related]
3. Non-invasive Doppler-derived cardiac output: a validation study comparing this technique with thermodilution and Fick methods.
Davies JN; Allen DR; Chant AD
Eur J Vasc Surg; 1991 Oct; 5(5):497-500. PubMed ID: 1959678
[TBL] [Abstract][Full Text] [Related]
4. Clinical evaluation of transtracheal Doppler for continuous cardiac output estimation.
Hausen B; Schäfers HJ; Rohde R; Haverich A
Anesth Analg; 1992 Jun; 74(6):800-4. PubMed ID: 1595910
[TBL] [Abstract][Full Text] [Related]
5. Transtracheal Doppler: a new procedure for continuous cardiac output measurement.
Abrams JH; Weber RE; Holmen KD
Anesthesiology; 1989 Jan; 70(1):134-8. PubMed ID: 2643365
[TBL] [Abstract][Full Text] [Related]
6. Transtracheal Doppler cardiac output monitoring: comparison to thermodilution during noncardiac surgery.
Perrino AC; O'Connor T; Luther M
Anesth Analg; 1994 Jun; 78(6):1060-6. PubMed ID: 8198259
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous cardiac output measurements by transtracheal Doppler, electromagnetic flow meter, and thermodilution during various hemodynamic states in pigs.
Gregoretti S; Henderson CT; Bradley EL
Anesth Analg; 1991 Oct; 73(4):455-9. PubMed ID: 1680299
[TBL] [Abstract][Full Text] [Related]
8. Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system.
Cariou A; Monchi M; Joly LM; Bellenfant F; Claessens YE; Thébert D; Brunet F; Dhainaut JF
Crit Care Med; 1998 Dec; 26(12):2066-72. PubMed ID: 9875922
[TBL] [Abstract][Full Text] [Related]
9. [Measuring stroke volume of the ascending aorta with an extravascular Doppler ultrasound probe in comparison with aortic thermodilution].
Vogt S; Troitzsch D; Abdul-Khaliq H; Späth S; Wolff MH; Lange PE; Moosdorf R
Biomed Tech (Berl); 2000 Apr; 45(4):78-81. PubMed ID: 10829540
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous intraoperative measurement of cardiac output by thermodilution and transtracheal Doppler.
Siegel LC; Fitzgerald DC; Engstrom RH
Anesthesiology; 1991 Apr; 74(4):664-9. PubMed ID: 2008947
[TBL] [Abstract][Full Text] [Related]
11. Noninvasive measurement of cardiac output during surgery using a new continuous-wave Doppler esophageal probe.
Kumar A; Minagoe S; Thangathurai D; Mikhail M; Novia D; Viljoen JF; Rahimtoola SH; Chandraratna PA
Am J Cardiol; 1989 Oct; 64(12):793-8. PubMed ID: 2801532
[TBL] [Abstract][Full Text] [Related]
12. Measurement of cardiac output with the Quantascope, a novel Doppler device: comparison with thermodilution.
Cross SJ; Lee HS; Jennings K; Rawles J
Eur Heart J; 1993 Jun; 14(6):809-11. PubMed ID: 8179644
[TBL] [Abstract][Full Text] [Related]
13. Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.
Blissitt KJ; Young LE; Jones RS; Darke PG; Utting J
Equine Vet J; 1997 Jan; 29(1):18-25. PubMed ID: 9031859
[TBL] [Abstract][Full Text] [Related]
14. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
Corley A; Barnett AG; Mullany D; Fraser JF
Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
[TBL] [Abstract][Full Text] [Related]
15. [Clinical study of neonatal cardiac output measurement methods].
Zheng ML; Sun X; Zhong J; He SR; Pan W; Pang CC; Sun YX; Liu YM
Zhonghua Er Ke Za Zhi; 2013 Jan; 51(1):58-63. PubMed ID: 23527933
[TBL] [Abstract][Full Text] [Related]
16. Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter.
Thom O; Taylor DM; Wolfe RE; Cade J; Myles P; Krum H; Wolfe R
Br J Anaesth; 2009 Dec; 103(6):800-4. PubMed ID: 19864307
[TBL] [Abstract][Full Text] [Related]
17. Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation.
; Knirsch W; Kretschmar O; Tomaske M; Stutz K; Nagdyman N; Balmer C; Schmitz A; Berger F; Bauersfeld U; Weiss M
Anaesthesia; 2008 Aug; 63(8):851-5. PubMed ID: 18557743
[TBL] [Abstract][Full Text] [Related]
18. Intraoperative assessment of the Lawrence 3000 Doppler Cardiac Output Monitor.
Stein MS; Barratt SM; Purcell GJ
Anaesth Intensive Care; 1991 May; 19(2):251-5. PubMed ID: 2069250
[TBL] [Abstract][Full Text] [Related]
19. Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: comparison with thermodilution.
Young LE; Blissitt KJ; Bartram DH; Clutton RE; Molony V; Jones RS
Br J Anaesth; 1996 Dec; 77(6):773-80. PubMed ID: 9014632
[TBL] [Abstract][Full Text] [Related]
20. Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter.
Lafanechère A; Albaladejo P; Raux M; Geeraerts T; Bocquet R; Wernet A; Castier Y; Marty J
J Cardiothorac Vasc Anesth; 2006 Feb; 20(1):26-30. PubMed ID: 16458209
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]