These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
242 related articles for article (PubMed ID: 17434071)
1. Injection rate threshold of triple-lumen central venous catheters: an in vitro study. Zamos DT; Emch TM; Patton HA; D'Amico FJ; Bansal SK Acad Radiol; 2007 May; 14(5):574-8. PubMed ID: 17434071 [TBL] [Abstract][Full Text] [Related]
2. Central venous catheter integrity during mechanical power injection of iodinated contrast medium. Macha DB; Nelson RC; Howle LE; Hollingsworth JW; Schindera ST Radiology; 2009 Dec; 253(3):870-8. PubMed ID: 19789224 [TBL] [Abstract][Full Text] [Related]
3. Power injection of microcatheters: an in vitro comparison. Brown DB; Papadouris DC; Davis RV; Vedantham S; Pilgram TK J Vasc Interv Radiol; 2005 Jan; 16(1):101-6. PubMed ID: 15640416 [TBL] [Abstract][Full Text] [Related]
4. In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media. Ruess L; Bulas DI; Rivera O; Markle BM Radiology; 1997 Jun; 203(3):625-9. PubMed ID: 9169679 [TBL] [Abstract][Full Text] [Related]
5. [Contrast media pressure injection using a portal catheter system--results of an in vitro study]. Gebauer B; Teichgräber UK; Hothan T; Felix R; Wagner HJ Rofo; 2005 Oct; 177(10):1417-23. PubMed ID: 16170712 [TBL] [Abstract][Full Text] [Related]
6. Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation. Herts BR; Cohen MA; McInroy B; Davros WJ; Zepp RC; Einstein DM Radiology; 1996 Sep; 200(3):731-5. PubMed ID: 8756923 [TBL] [Abstract][Full Text] [Related]
7. Bursting pressure of triple-lumen central venous catheters under static and dynamic loads. Beckingham T; Roberts A; St John A; O'Callaghan G J Vasc Access; 2017 Sep; 18(5):430-435. PubMed ID: 28777405 [TBL] [Abstract][Full Text] [Related]
8. Safety and feasibility of using a central venous catheter for rapid contrast injection rates. Sanelli PC; Deshmukh M; Ougorets I; Caiati R; Heier LA AJR Am J Roentgenol; 2004 Dec; 183(6):1829-34. PubMed ID: 15547237 [TBL] [Abstract][Full Text] [Related]
9. Peripheral intravenous power injection of iodinated contrast media: the impact of temperature on maximum injection pressures at different cannula sizes. Schwab SA; Kuefner MA; Anders K; Adamietz B; Heinrich MC; Baigger JF; Janka R; Uder M; Kramer M Acad Radiol; 2009 Dec; 16(12):1502-8. PubMed ID: 19896067 [TBL] [Abstract][Full Text] [Related]
10. Maximal flow rates possible during power injection through currently available PICCs: an in vitro study. Salis AI; Eclavea A; Johnson MS; Patel NH; Wong DG; Tennery G J Vasc Interv Radiol; 2004 Mar; 15(3):275-81. PubMed ID: 15028813 [TBL] [Abstract][Full Text] [Related]
11. Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study. Schwab SA; Uder M; Anders K; Heinrich MC; Kuefner MA Rofo; 2009 Apr; 181(4):355-61. PubMed ID: 19280548 [TBL] [Abstract][Full Text] [Related]
12. Impact of different vein catheter sizes for mechanical power injection in CT: in vitro evaluation with use of a circulation phantom. Behrendt FF; Bruners P; Keil S; Plumhans C; Mahnken AH; Stanzel S; Das M; Günther RW; Mühlenbruch G Cardiovasc Intervent Radiol; 2009 Jan; 32(1):25-31. PubMed ID: 18521665 [TBL] [Abstract][Full Text] [Related]
13. Power injection of contrast media via peripherally inserted central catheters for CT. Coyle D; Bloomgarden D; Beres R; Patel S; Sane S; Hurst E J Vasc Interv Radiol; 2004 Aug; 15(8):809-14. PubMed ID: 15297584 [TBL] [Abstract][Full Text] [Related]
14. Assessing the adequacy of peripherally inserted central catheters for power injection of intravenous contrast agents for CT. Williamson EE; McKinney JM J Comput Assist Tomogr; 2001; 25(6):932-7. PubMed ID: 11711806 [TBL] [Abstract][Full Text] [Related]
15. Power injection of contrast media using central venous catheters: feasibility, safety, and efficacy. Herts BR; O'Malley CM; Wirth SL; Lieber ML; Pohlman B AJR Am J Roentgenol; 2001 Feb; 176(2):447-53. PubMed ID: 11159092 [TBL] [Abstract][Full Text] [Related]
16. Power injection of peripherally inserted central catheters. Rivitz SM; Drucker EA J Vasc Interv Radiol; 1997; 8(5):857-63. PubMed ID: 9314379 [TBL] [Abstract][Full Text] [Related]
17. Power injection of iodinated intravenous contrast material through acute and chronic hemodialysis catheters. Hollander S; Mojibian H; Emery M; Tal MG J Vasc Access; 2012; 13(1):61-4. PubMed ID: 21725947 [TBL] [Abstract][Full Text] [Related]
18. Hemodialysis catheter integrity during mechanical power injection of iodinated contrast medium for computed tomography angiography. Schwartz FR; Lewis DS; King AE; Murphy FG; Howle LE; Kim CY; Nelson RC Abdom Radiol (NY); 2021 Jun; 46(6):2961-2967. PubMed ID: 33386919 [TBL] [Abstract][Full Text] [Related]
19. Power injectable peripherally inserted central venous catheter lines frequently flip after power injection of contrast. Lozano LA; Marn C; Goodman LR J Comput Assist Tomogr; 2012; 36(4):427-30. PubMed ID: 22805672 [TBL] [Abstract][Full Text] [Related]
20. Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT. Wienbeck S; Fischbach R; Kloska SP; Seidensticker P; Osada N; Heindel W; Juergens KU AJR Am J Roentgenol; 2010 Oct; 195(4):825-9. PubMed ID: 20858804 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]