These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 17436175)

  • 1. Preamputation evaluation of limb perfusion with laser Doppler imaging and transcutaneous gases.
    Figoni SF; Scremin OU; Kunkel CF; Opava-Rutter D; Johnson J; Schmitter ED; Scremin AM
    J Rehabil Res Dev; 2006; 43(7):891-904. PubMed ID: 17436175
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preamputation evaluation of lower-limb skeletal muscle perfusion with H(2) (15)O positron emission tomography.
    Scremin OU; Figoni SF; Norman K; Scremin AM; Kunkel CF; Opava-Rutter D; Schmitter ED; Bert A; Mandelkern M
    Am J Phys Med Rehabil; 2010 Jun; 89(6):473-86. PubMed ID: 20357647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcutaneous carbon dioxide tension for the evaluation of limb ischemia.
    Sugimoto I; Ohta T; Ishibashi H; Iwata H; Kawanishi J; Yamada T; Tadakoshi M; Hida N; Sato T; Shimizu T
    Surg Today; 2009; 39(1):9-13. PubMed ID: 19132461
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Scanning laser-Doppler imaging of leg- and foot-skin perfusion in normal subjects: analysis of age, gender, site, and laser-type effects.
    Kunkel CF; Figoni SF; Baumgarten JM; Carvalho CM; Kim HS; Oshiro RL; Zirovich MD; Scremin OU; Scremin AM
    Am J Phys Med Rehabil; 2007 Apr; 86(4):262-71. PubMed ID: 17413539
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prediction of imminent amputation in patients with non-reconstructible leg ischemia by means of microcirculatory investigations.
    Ubbink DT; Spincemaille GH; Reneman RS; Jacobs MJ
    J Vasc Surg; 1999 Jul; 30(1):114-21. PubMed ID: 10394161
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Laser-Doppler flowmetry and arterial diseases of the limbs. Correlations with measurement of transcutaneous oxygen pressure].
    Schmidt C; Adechokan S; Mouhli J
    J Mal Vasc; 1996; 21(5):294-8. PubMed ID: 9026545
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is transcutaneous oxygen and carbon dioxide monitoring indispensable in short- and long-term therapeutic management of non-reconstructable lower critical limb ischemia?
    Melillo E; Nuti M; Pedrinelli R; Buttitta F; Balbarini A
    Minerva Cardioangiol; 2006 Aug; 54(4):481-98. PubMed ID: 17016419
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flap monitoring by transcutaneous PO2 and PCO2: importance of transcutaneous PCO2 in determining follow-up treatment for compromised free flaps.
    Hashimoto I; Nakanishi H; Takiwaki H; Takase MT; Yamano M; Sedo H
    J Reconstr Microsurg; 2007 Jul; 23(5):269-74. PubMed ID: 17876730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of toe pressure and transcutaneous oxygen measurements in management of chronic critical leg ischemia: a diagnostic randomized clinical trial.
    de Graaff JC; Ubbink DT; Legemate DA; Tijssen JG; Jacobs MJ
    J Vasc Surg; 2003 Sep; 38(3):528-34. PubMed ID: 12947272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A review of microvascular measurements in wound healing.
    Iabichella ML; Melillo E; Mosti G
    Int J Low Extrem Wounds; 2006 Sep; 5(3):181-99. PubMed ID: 16928674
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Laser Doppler flowmetry, transcutaneous oxygen tension measurements and Doppler pressure compared in patients undergoing amputation.
    Lantsberg L; Goldman M
    Eur J Vasc Surg; 1991 Apr; 5(2):195-7. PubMed ID: 2037090
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A functional murine model of hindlimb demand ischemia.
    Peck MA; Crawford RS; Abularrage CJ; Patel VI; Conrad MF; Yoo JH; Watkins MT; Albadawi H
    Ann Vasc Surg; 2010 May; 24(4):532-7. PubMed ID: 20363101
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of elevation and dependency to enhance the predictive value of transcutaneous oxygen pressure measurements in the assessment of foot amputation healing.
    Andrews KL; Boon AJ; Dib M; Liedl DA; Yacyshyn A; Yacyshyn V
    PM R; 2010 Sep; 2(9):829-34. PubMed ID: 20869682
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Repeated blood gas monitoring in healthy children and adolescents by the transcutaneous route.
    Lagerkvist AL; Sten G; Redfors S; Holmgren D
    Pediatr Pulmonol; 2003 Apr; 35(4):274-9. PubMed ID: 12629624
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue.
    Svalestad J; Hellem S; Vaagbø G; Irgens A; Thorsen E
    Microvasc Res; 2010 Jan; 79(1):29-33. PubMed ID: 19837098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The predictive value of laser Doppler fluxmetry and transcutaneous oximetry for clinical outcome in patients undergoing revascularisation for severe leg ischaemia.
    Ray SA; Buckenham TM; Belli AM; Taylor RS; Dormandy JA
    Eur J Vasc Endovasc Surg; 1997 Jan; 13(1):54-9. PubMed ID: 9046915
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous oxygen tension in patients with calciphylaxis.
    Wilmer WA; Voroshilova O; Singh I; Middendorf DF; Cosio FG
    Am J Kidney Dis; 2001 Apr; 37(4):797-806. PubMed ID: 11273880
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcutaneous oxygen tension: a useful predictor of ulcer healing in critical limb ischaemia.
    Ruangsetakit C; Chinsakchai K; Mahawongkajit P; Wongwanit C; Mutirangura P
    J Wound Care; 2010 May; 19(5):202-6. PubMed ID: 20505593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relationship between the blood perfusion values determined by laser speckle imaging and laser Doppler imaging in normal skin and port wine stains.
    Chen D; Ren J; Wang Y; Zhao H; Li B; Gu Y
    Photodiagnosis Photodyn Ther; 2016 Mar; 13():1-9. PubMed ID: 26592337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spatial heterogeneity in normal skin perfusion recorded with laser Doppler imaging and flowmetry.
    Wårdell K; Braverman IM; Silverman DG; Nilsson GE
    Microvasc Res; 1994 Jul; 48(1):26-38. PubMed ID: 7990721
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.