These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 1743740)

  • 1. A low-cost fiber-optic strain gage system for biological applications.
    George DT; Bogen DK
    IEEE Trans Biomed Eng; 1991 Sep; 38(9):919-24. PubMed ID: 1743740
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A new method for small displacement test and measurement based on the light reflection theory].
    Chen RW; Sun YF; Chen Y
    Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Jan; 24(1):21-4. PubMed ID: 15768967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patient isolation in multichannel bioelectric recordings by digital transmission through a single optical fiber.
    MettingVanRijn AC; Kuiper AP; Linnenbank AC; Grimbergen CA
    IEEE Trans Biomed Eng; 1993 Mar; 40(3):302-8. PubMed ID: 8335335
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Integration of optical fiber light guide, fluorescence detection system, and multichannel disposable microfluidic chip.
    Irawan R; Tjin SC; Fang X; Fu CY
    Biomed Microdevices; 2007 Jun; 9(3):413-9. PubMed ID: 17473985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique.
    Battista L; Sciuto SA; Scorza A
    Rev Sci Instrum; 2013 Mar; 84(3):035005. PubMed ID: 23556844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fiber optic system for measuring dynamic mechanical properties of embryonic tissues.
    Moore SW
    IEEE Trans Biomed Eng; 1994 Jan; 41(1):45-50. PubMed ID: 8200667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The design of an optical fiber pressure transducer for use in the upper airways.
    Goodyer PD; Fothergill JC; Jones NB; Hanning CD
    IEEE Trans Biomed Eng; 1996 Jun; 43(6):600-6. PubMed ID: 8987264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scanning tooth surface reflectometer.
    Gabathuler H
    Helv Odontol Acta; 1975 Apr; 19(1):37-9. PubMed ID: 1150474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microcapillary electrophoresis chips utilizing controllable micro-lens structures and buried optical fibers for on-line optical detection.
    Hsiung SK; Lee CH; Lee GB
    Electrophoresis; 2008 May; 29(9):1866-73. PubMed ID: 18393334
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fiber optic light collection system for scanning-tunneling-microscope-induced light emission.
    Watkins NJ; Long JP; Kafafi ZH; Mäkinen AJ
    Rev Sci Instrum; 2007 May; 78(5):053707. PubMed ID: 17552825
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: theory, working principle, and static calibration.
    Schena E; Saccomandi P; Silvestri S
    Rev Sci Instrum; 2013 Feb; 84(2):024301. PubMed ID: 23464229
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical and optical characteristics of a new fiber optical system used for cardiac contraction measurement.
    Kloppe A; Hoeland K; Müller S; Hexamer M; Nowack G; Mügge A; Werner J
    Med Eng Phys; 2004 Oct; 26(8):687-94. PubMed ID: 15471697
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An optical fiber transducer for single myofibril force measurement.
    Fearn LA; Bartoo ML; Myers JA; Pollack GH
    IEEE Trans Biomed Eng; 1993 Nov; 40(11):1127-32. PubMed ID: 8307596
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a dual function sensor system for measuring pressure and temperature at the tip of a single optical fiber.
    Wolthuis R; Mitchell G; Hartl J; Saaski E
    IEEE Trans Biomed Eng; 1993 Mar; 40(3):298-302. PubMed ID: 8335334
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Real-time frequency domain temperature and oxygen sensor with a single optical fiber.
    Liao SC; Xu Z; Izatt JA; Alcala JR
    IEEE Trans Biomed Eng; 1997 Nov; 44(11):1114-21. PubMed ID: 9353991
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fiber-optic biosensor to assess circulating phagocyte activity by chemiluminescence.
    Magrisso M; Etzion O; Pilch G; Novodvoretz A; Perez-Avraham G; Schlaeffer F; Marks R
    Biosens Bioelectron; 2006 Jan; 21(7):1210-8. PubMed ID: 15978799
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fiber-optic probes for in vivo Raman spectroscopy in the high-wavenumber region.
    Santos LF; Wolthuis R; Koljenović S; Almeida RM; Puppels GJ
    Anal Chem; 2005 Oct; 77(20):6747-52. PubMed ID: 16223266
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two-point electrical-fluorescence recording from heart with optical fibers.
    Krauthamer V; Davis CC; Gan ET
    IEEE Trans Biomed Eng; 1994 Dec; 41(12):1191-4. PubMed ID: 7851921
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The possibilities of using fiber optic luminescent light sources in medical-biological studies].
    Monich VA; Krivosheina IV; Malinovskaia SL; Kontorshchikova KN
    Med Tekh; 1993; (2):13-4. PubMed ID: 8502147
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An optical neural interface: in vivo control of rodent motor cortex with integrated fiberoptic and optogenetic technology.
    Aravanis AM; Wang LP; Zhang F; Meltzer LA; Mogri MZ; Schneider MB; Deisseroth K
    J Neural Eng; 2007 Sep; 4(3):S143-56. PubMed ID: 17873414
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.