191 related articles for article (PubMed ID: 17441241)
1. Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams.
Karaj E; Righi S; Di Martino F
Med Phys; 2007 Mar; 34(3):952-8. PubMed ID: 17441241
[TBL] [Abstract][Full Text] [Related]
2. Absolute and relative dose measurements with Gafchromic EBT film for high energy electron beams with different doses per pulse.
Fiandra C; Ragona R; Ricardi U; Anglesio S; Giglioli FR
Med Phys; 2008 Dec; 35(12):5463-70. PubMed ID: 19175106
[TBL] [Abstract][Full Text] [Related]
3. Ion recombination correction for very high dose-per-pulse high-energy electron beams.
Di Martino F; Giannelli M; Traino AC; Lazzeri M
Med Phys; 2005 Jul; 32(7):2204-10. PubMed ID: 16121574
[TBL] [Abstract][Full Text] [Related]
4. Ion recombination correction for very high dose-per-pulse high-energy electron beams.
Di Martino F; Giannelli M; Traino AC; Lazzeri M
Med Phys; 2005 Jul; 32(7Part1):2204-2210. PubMed ID: 28493588
[TBL] [Abstract][Full Text] [Related]
5. Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
Saiful Huq M; Song H; Andreo P; Houser CJ
Med Phys; 2001 Oct; 28(10):2077-87. PubMed ID: 11695769
[TBL] [Abstract][Full Text] [Related]
6. The saturation loss for plane parallel ionization chambers at high dose per pulse values.
Piermattei A; Canne SD; Azario L; Russo A; Fidanzio A; Micelit R; Soriani AT; Orvieto A; Fantini M
Phys Med Biol; 2000 Jul; 45(7):1869-83. PubMed ID: 10943925
[TBL] [Abstract][Full Text] [Related]
7. Charge collection efficiency in ionization chambers exposed to electron beams with high dose per pulse.
Laitano RF; Guerra AS; Pimpinella M; Caporali C; Petrucci A
Phys Med Biol; 2006 Dec; 51(24):6419-36. PubMed ID: 17148826
[TBL] [Abstract][Full Text] [Related]
8. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.
Jaccard M; Petersson K; Buchillier T; Germond JF; Durán MT; Vozenin MC; Bourhis J; Bochud FO; Bailat C
Med Phys; 2017 Feb; 44(2):725-735. PubMed ID: 28019660
[TBL] [Abstract][Full Text] [Related]
9. Calibration of low-energy electron beams from a mobile linear accelerator with plane-parallel chambers using both TG-51 and TG-21 protocols.
Beddar AS; Tailor RC
Phys Med Biol; 2004 Apr; 49(8):N105-10. PubMed ID: 15152696
[TBL] [Abstract][Full Text] [Related]
10. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.
Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM
Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223
[TBL] [Abstract][Full Text] [Related]
11. The characterization of the Advanced Markus ionization chamber for use in reference electron dosimetry in the UK.
Pearce J; Thomas R; Dusautoy A
Phys Med Biol; 2006 Feb; 51(3):473-83. PubMed ID: 16424576
[TBL] [Abstract][Full Text] [Related]
12. High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber.
Petersson K; Jaccard M; Germond JF; Buchillier T; Bochud F; Bourhis J; Vozenin MC; Bailat C
Med Phys; 2017 Mar; 44(3):1157-1167. PubMed ID: 28094853
[TBL] [Abstract][Full Text] [Related]
13. The Italian affair: the employment of parallel-plate ionization chambers for dose measurements in high dose-per-pulse IORT electron beams.
Cella L; Liuzzi R; Salvatore M
Med Phys; 2010 Jun; 37(6):2918-24. PubMed ID: 20632603
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric characteristics of electron beams produced by two mobile accelerators, Novac7 and Liac, for intraoperative radiation therapy through Monte Carlo simulation.
Righi S; Karaj E; Felici G; Di Martino F
J Appl Clin Med Phys; 2013 Jan; 14(1):3678. PubMed ID: 23318376
[TBL] [Abstract][Full Text] [Related]
15. Direct determination of k
Krauss A; Kapsch RP
Phys Med Biol; 2018 Feb; 63(3):035041. PubMed ID: 29327693
[TBL] [Abstract][Full Text] [Related]
16. Verification of absorbed doses determined with thimble and parallel-plate ionization chambers in clinical electron beams using ferrous sulphate dosimetry.
Van der Plaetsen A; Seuntjens J; Thierens H; Vynckier S
Med Phys; 1994 Jan; 21(1):37-44. PubMed ID: 8164587
[TBL] [Abstract][Full Text] [Related]
17. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry.
Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J
Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221
[TBL] [Abstract][Full Text] [Related]
18. Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies.
Tailor RC; Hanson WF
Med Phys; 2002 Jul; 29(7):1464-72. PubMed ID: 12148727
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.
Pimpinella M; Mihailescu D; Guerra AS; Laitano RF
Phys Med Biol; 2007 Oct; 52(20):6197-214. PubMed ID: 17921580
[TBL] [Abstract][Full Text] [Related]
20. Output factor measurement in high dose-per-pulse IORT electron beams.
Pimpinella M; Andreoli S; De Angelis C; Della Monaca S; D'Arienzo M; Menegotti L
Phys Med; 2019 May; 61():94-102. PubMed ID: 31151586
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]