310 related articles for article (PubMed ID: 17441255)
1. A computer simulation platform for the optimization of a breast tomosynthesis system.
Zhou J; Zhao B; Zhao W
Med Phys; 2007 Mar; 34(3):1098-109. PubMed ID: 17441255
[TBL] [Abstract][Full Text] [Related]
2. Optimization of the acquisition geometry in digital tomosynthesis of the breast.
Sechopoulos I; Ghetti C
Med Phys; 2009 Apr; 36(4):1199-207. PubMed ID: 19472626
[TBL] [Abstract][Full Text] [Related]
3. Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system.
Zhao B; Zhao W
Med Phys; 2008 May; 35(5):1978-87. PubMed ID: 18561674
[TBL] [Abstract][Full Text] [Related]
4. Three-dimensional linear system analysis for breast tomosynthesis.
Zhao B; Zhao W
Med Phys; 2008 Dec; 35(12):5219-32. PubMed ID: 19175081
[TBL] [Abstract][Full Text] [Related]
5. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging.
Gong X; Glick SJ; Liu B; Vedula AA; Thacker S
Med Phys; 2006 Apr; 33(4):1041-52. PubMed ID: 16696481
[TBL] [Abstract][Full Text] [Related]
6. A comparison of reconstruction algorithms for breast tomosynthesis.
Wu T; Moore RH; Rafferty EA; Kopans DB
Med Phys; 2004 Sep; 31(9):2636-47. PubMed ID: 15487747
[TBL] [Abstract][Full Text] [Related]
7. Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.
Hu YH; Zhao B; Zhao W
Med Phys; 2008 Dec; 35(12):5242-52. PubMed ID: 19175083
[TBL] [Abstract][Full Text] [Related]
8. Imaging properties of digital magnification radiography.
Boyce SJ; Samei E
Med Phys; 2006 Apr; 33(4):984-96. PubMed ID: 16696475
[TBL] [Abstract][Full Text] [Related]
9. Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications.
Chen Y; Lo JY; Dobbins JT
Med Phys; 2007 Oct; 34(10):3885-92. PubMed ID: 17985634
[TBL] [Abstract][Full Text] [Related]
10. Oblique reconstructions in tomosynthesis. II. Super-resolution.
Acciavatti RJ; Maidment AD
Med Phys; 2013 Nov; 40(11):111912. PubMed ID: 24320445
[TBL] [Abstract][Full Text] [Related]
11. Implementation and evaluation of an expectation maximization reconstruction algorithm for gamma emission breast tomosynthesis.
Gong Z; Klanian K; Patel T; Sullivan O; Williams MB
Med Phys; 2012 Dec; 39(12):7580-92. PubMed ID: 23231306
[TBL] [Abstract][Full Text] [Related]
12. Oblique reconstructions in tomosynthesis. I. Linear systems theory.
Acciavatti RJ; Maidment AD
Med Phys; 2013 Nov; 40(11):111911. PubMed ID: 24320444
[TBL] [Abstract][Full Text] [Related]
13. Experimental validation of a three-dimensional linear system model for breast tomosynthesis.
Zhao B; Zhou J; Hu YH; Mertelmeier T; Ludwig J; Zhao W
Med Phys; 2009 Jan; 36(1):240-51. PubMed ID: 19235392
[TBL] [Abstract][Full Text] [Related]
14. Three-dimensional cascaded system analysis of a 50 µm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.
Zhao C; Vassiljev N; Konstantinidis AC; Speller RD; Kanicki J
Phys Med Biol; 2017 Mar; 62(5):1994-2017. PubMed ID: 28072394
[TBL] [Abstract][Full Text] [Related]
15. Task-based performance analysis of FBP, SART and ML for digital breast tomosynthesis using signal CNR and Channelised Hotelling Observers.
Van de Sompel D; Brady SM; Boone J
Med Image Anal; 2011 Feb; 15(1):53-70. PubMed ID: 20713313
[TBL] [Abstract][Full Text] [Related]
16. A comparison of reconstruction algorithms for C-arm mammography tomosynthesis.
Rakowski JT; Dennis MJ
Med Phys; 2006 Aug; 33(8):3018-32. PubMed ID: 16964880
[TBL] [Abstract][Full Text] [Related]
17. Digital tomosynthesis: technique.
Yaffe MJ; Mainprize JG
Radiol Clin North Am; 2014 May; 52(3):489-97. PubMed ID: 24792651
[TBL] [Abstract][Full Text] [Related]
18. A mathematical model platform for optimizing a multiprojection breast imaging system.
Chawla AS; Samei E; Saunders RS; Lo JY; Baker JA
Med Phys; 2008 Apr; 35(4):1337-45. PubMed ID: 18491528
[TBL] [Abstract][Full Text] [Related]
19. Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.
Berggren K; Cederström B; Lundqvist M; Fredenberg E
Med Phys; 2018 Oct; 45(10):4392-4401. PubMed ID: 30091470
[TBL] [Abstract][Full Text] [Related]
20. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
Zhao C; Kanicki J
Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]