These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 17445270)

  • 1. Changes in pulse pressure variability during cardiac resynchronization therapy in mechanically ventilated patients.
    Keyl C; Stockinger J; Laule S; Staier K; Schiebeling-Römer J; Wiesenack C
    Crit Care; 2007; 11(2):R46. PubMed ID: 17445270
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acute Hemodynamic Effects of Cardiac Resynchronization Therapy Versus Alternative Pacing Strategies in Patients With Left Ventricular Assist Devices.
    Tomashitis B; Baicu CF; Butschek RA; Jackson GR; Winterfield J; Tedford RJ; Zile MR; Gold MR; Houston BA
    J Am Heart Assoc; 2021 Mar; 10(6):e018127. PubMed ID: 33663225
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy.
    Ruwald MH; Mittal S; Ruwald AC; Aktas MK; Daubert JP; McNitt S; Al-Ahmad A; Jons C; Kutyifa V; Steinberg JS; Wang P; Moss AJ; Zareba W
    J Am Coll Cardiol; 2014 Sep; 64(10):971-81. PubMed ID: 25190230
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biventricular pacing (cardiac resynchronization therapy): an evidence-based analysis.
    Medical Advisory Secretariat
    Ont Health Technol Assess Ser; 2005; 5(13):1-60. PubMed ID: 23074464
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Acute hemodynamic effects of biventricular and left ventricular pacing in chronic pacemaker-dependent patients with advanced heart failure].
    Hansen C; Sperzel J; Neumann T; Pitschner HF; Neuzner J
    Z Kardiol; 2003 Oct; 92(10):862-8. PubMed ID: 14579051
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials.
    Wilkoff BL;
    Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of low versus high (>40 mm Hg) pulse pressure to predict the benefit of cardiac resynchronization therapy for heart failure (from the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy Trial).
    Sherazi S; Goldenberg I; Moss AJ; Solomon S; Kutyifa V; McNitt S; Shah AH; Huang DT; Aktas MK; Zareba W; Barsheshet A
    Am J Cardiol; 2014 Oct; 114(7):1053-8. PubMed ID: 25118116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pressure-volume loop analysis during implantation of biventricular pacemaker/cardiac resynchronization therapy device to optimize right and left ventricular pacing sites.
    Delnoy PP; Ottervanger JP; Luttikhuis HO; Vos DH; Elvan A; Ramdat Misier AR; Beukema WP; Steendijk P; van Hemel NM
    Eur Heart J; 2009 Apr; 30(7):797-804. PubMed ID: 19202156
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Left Bundle Branch Pacing Versus Biventricular Pacing for Acute Cardiac Resynchronization in Patients With Heart Failure.
    Liang Y; Wang J; Gong X; Lu H; Yu Z; Zhang L; Li M; Pan L; Chen X; Cui J; Zhang W; Li R; Zhou X; Huang W; Su Y; Ge J
    Circ Arrhythm Electrophysiol; 2022 Nov; 15(11):e011181. PubMed ID: 36306335
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of ventricular activation pattern and acute hemodynamics during multipoint left ventricular pacing.
    Menardi E; Ballari GP; Goletto C; Rossetti G; Vado A
    Heart Rhythm; 2015 Aug; 12(8):1762-9. PubMed ID: 25916565
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acute Hemodynamic Effects of Biventricular Pacing After Left Ventricular Assist Device.
    Joly JM; Acharya D; Doppalapudi H; Kay GN; Lin CP; Maddox WR; McElderry HT; Pamboukian SV; Plumb VJ; Rajapreyar IN; Tallaj JA; Yamada T; Kumar V
    J Card Fail; 2018 Oct; 24(10):716-718. PubMed ID: 30248397
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acute hemodynamic effects of right and left ventricular lead positions during the implantation of cardiac resynchronization therapy defibrillators.
    Stockinger J; Staier K; Schiebeling-Römer J; Keyl C
    Pacing Clin Electrophysiol; 2011 Nov; 34(11):1537-43. PubMed ID: 21797906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Eligibility of Pacemaker Patients for Subcutaneous Implantable Cardioverter Defibrillators.
    Ip JE; Wu MS; Kennel PJ; Thomas G; Liu CF; Cheung JW; Markowitz SM; Lerman BB
    J Cardiovasc Electrophysiol; 2017 May; 28(5):544-548. PubMed ID: 28185354
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I.
    Leclercq C; Burri H; Curnis A; Delnoy PP; Rinaldi CA; Sperzel J; Lee K; Calò L; Vicentini A; Concha JF; Thibault B
    Eur Heart J; 2019 Sep; 40(35):2979-2987. PubMed ID: 30859220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. His Resynchronization Versus Biventricular Pacing in Patients With Heart Failure and Left Bundle Branch Block.
    Arnold AD; Shun-Shin MJ; Keene D; Howard JP; Sohaib SMA; Wright IJ; Cole GD; Qureshi NA; Lefroy DC; Koa-Wing M; Linton NWF; Lim PB; Peters NS; Davies DW; Muthumala A; Tanner M; Ellenbogen KA; Kanagaratnam P; Francis DP; Whinnett ZI
    J Am Coll Cardiol; 2018 Dec; 72(24):3112-3122. PubMed ID: 30545450
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variation in optimal hemodynamic atrio-ventricular delay of biventricular pacing with different endocardial left ventricular lead locations using precision hemodynamics.
    Butcher CJT; Cantor E; Sohaib A; Shun-Shin MJ; Haynes R; Khan H; Kyriacou A; Shi R; Chen Z; Haldar S; Cleland JGF; Hussain W; Markides V; Jones DG; Lane RE; Mason MJ; Whinnett ZI; Francis DP; Wong T
    J Cardiovasc Electrophysiol; 2023 Jun; 34(6):1431-1440. PubMed ID: 36786511
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Complications of permanent cardiac pacing in patients with persistent left superior vena cava.
    Polewczyk A; Kutarski A; Czekajska-Chehab E; Adamczyk P; Boczar K; Polewczyk M; Janion M
    Cardiol J; 2014; 21(2):128-37. PubMed ID: 24526508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery: Acute Hemodynamic Assessment by Pressure-Volume Loops.
    Padeletti L; Pieragnoli P; Ricciardi G; Innocenti L; Checchi L; Padeletti M; Michelucci A; Picariello F; Valsecchi S
    Circ Arrhythm Electrophysiol; 2016 May; 9(5):. PubMed ID: 27162032
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left ventricular resynchronization predicted by individual performance of right and left univentricular pacing: a study on the impact of sequential biventricular pacing on ventricular dyssynchrony.
    Phillips KP; Harberts DB; Johnston LP; O'Donnell D
    Heart Rhythm; 2007 Feb; 4(2):147-53. PubMed ID: 17275748
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of the longest intrapatient left ventricular electrical delay may predict acute hemodynamic improvement in patients after cardiac resynchronization therapy.
    Zanon F; Baracca E; Pastore G; Fraccaro C; Roncon L; Aggio S; Noventa F; Mazza A; Prinzen F
    Circ Arrhythm Electrophysiol; 2014 Jun; 7(3):377-83. PubMed ID: 24668162
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.