115 related articles for article (PubMed ID: 1745345)
1. Transcranial Doppler ultrasound identifies patients with right-to-left cardiac or pulmonary shunts.
Chimowitz MI; Nemec JJ; Marwick TH; Lorig RJ; Furlan AJ; Salcedo EE
Neurology; 1991 Dec; 41(12):1902-4. PubMed ID: 1745345
[TBL] [Abstract][Full Text] [Related]
2. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients.
Devuyst G; Despland PA; Bogousslavsky J; Jeanrenaud X
Eur Neurol; 1997; 38(1):21-5. PubMed ID: 9252794
[TBL] [Abstract][Full Text] [Related]
3. Transesophageal contrast echocardiography and color flow mapping: methods of choice for the detection of shunts at the atrial level?
de Belder MA; Tourikis L; Griffith M; Leech G; Camm AJ
Am Heart J; 1992 Dec; 124(6):1545-50. PubMed ID: 1462912
[TBL] [Abstract][Full Text] [Related]
4. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale.
Jauss M; Kaps M; Keberle M; Haberbosch W; Dorndorf W
Stroke; 1994 Jun; 25(6):1265-7. PubMed ID: 7911265
[TBL] [Abstract][Full Text] [Related]
5. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts.
Nemec JJ; Marwick TH; Lorig RJ; Davison MB; Chimowitz MI; Litowitz H; Salcedo EE
Am J Cardiol; 1991 Dec; 68(15):1498-502. PubMed ID: 1746433
[TBL] [Abstract][Full Text] [Related]
6. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents.
Droste DW; Kriete JU; Stypmann J; Castrucci M; Wichter T; Tietje R; Weltermann B; Young P; Ringelstein EB
Stroke; 1999 Sep; 30(9):1827-32. PubMed ID: 10471431
[TBL] [Abstract][Full Text] [Related]
7. Incidental diagnosis of four pulmonary arteriovenous fistulas during patent foramen ovale closure: a case report.
Andreis A; Agnoletti G; Scacciatella P
Cardiol Young; 2020 Sep; 30(9):1363-1365. PubMed ID: 32713372
[TBL] [Abstract][Full Text] [Related]
8. Differential diagnosis between patent foramen ovale and pulmonary arteriovenous fistula in two patients with previous cryptogenic stroke caused by presumed paradoxical embolism.
Chessa M; Drago M; Krantunkov P; Bini MR; Butera G; De Rosa G; Bossone E; Carminati M
J Am Soc Echocardiogr; 2002 Aug; 15(8):845-6. PubMed ID: 12174357
[TBL] [Abstract][Full Text] [Related]
9. Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts.
Droste DW; Lakemeier S; Wichter T; Stypmann J; Dittrich R; Ritter M; Moeller M; Freund M; Ringelstein EB
Stroke; 2002 Sep; 33(9):2211-6. PubMed ID: 12215589
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous bilateral contrast transcranial doppler monitoring in patients with intracardiac and intrapulmonary shunts.
Horner S; Ni XS; Weihs W; Harb S; Augustin M; Duft M; Niederkorn K
J Neurol Sci; 1997 Sep; 150(1):49-57. PubMed ID: 9260857
[TBL] [Abstract][Full Text] [Related]
11. Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients.
Souteyrand G; Motreff P; Lusson JR; Rodriguez R; Geoffroy E; Dauphin C; Boire JY; Lamaison D; Cassagnes J
Eur J Echocardiogr; 2006 Mar; 7(2):147-54. PubMed ID: 15927538
[TBL] [Abstract][Full Text] [Related]
12. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli.
Droste DW; Reisener M; Kemény V; Dittrich R; Schulte-Altedorneburg G; Stypmann J; Wichter T; Ringelstein EB
Stroke; 1999 May; 30(5):1014-8. PubMed ID: 10229737
[TBL] [Abstract][Full Text] [Related]
13. Transcranial Doppler with contrast injection for the detection of patent foramen ovale in stroke patients.
Di Tullio M; Sacco RL; Massaro A; Venketasubramanian N; Sherman D; Hoffmann M; Mohr JP; Homma S
Int J Card Imaging; 1993 Mar; 9(1):1-5. PubMed ID: 8491996
[TBL] [Abstract][Full Text] [Related]
14. Detection of patent foramen ovale by transcranial Doppler and carotid duplex ultrasonography: a comparison with transoesophageal echocardiography.
Nygren AT; Jogestrand T
Clin Physiol; 1998 Jul; 18(4):327-30. PubMed ID: 9715758
[TBL] [Abstract][Full Text] [Related]
15. Non-smoke spontaneous contrast in left atrium intensified by respiratory manoeuvres: a new transoesophageal echocardiographic observation.
Van Camp G; Cosyns B; Vandenbossche JL
Br Heart J; 1994 Nov; 72(5):446-51. PubMed ID: 7818961
[TBL] [Abstract][Full Text] [Related]
16. Optimized transcranial Doppler technique for the diagnosis of cardiac right-to-left shunts.
Albert A; Müller HR; Hetzel A
J Neuroimaging; 1997 Jul; 7(3):159-63. PubMed ID: 9237435
[TBL] [Abstract][Full Text] [Related]
17. Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale.
Maffè S; Dellavesa P; Zenone F; Paino AM; Paffoni P; Perucca A; Kozel D; Signorotti F; Bielli M; Parravicini U; Pardo NF; Cucchi L; Aymele AG; Zanetta M
Eur J Echocardiogr; 2010 Jan; 11(1):57-63. PubMed ID: 19910318
[TBL] [Abstract][Full Text] [Related]
18. Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale.
Daniëls C; Weytjens C; Cosyns B; Schoors D; De Sutter J; Paelinck B; Muyldermans L; Van Camp G
Eur J Echocardiogr; 2004 Dec; 5(6):449-52. PubMed ID: 15556821
[TBL] [Abstract][Full Text] [Related]
19. Contrast transcranial doppler ultrasound in the detection of right-to-left shunts : time window and threshold in microbubble numbers.
Droste DW; Silling K; Stypmann J; Grude M; Kemény V; Wichter T; Kühne K; Ringelstein EB
Stroke; 2000 Jul; 31(7):1640-5. PubMed ID: 10884466
[TBL] [Abstract][Full Text] [Related]
20. Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography.
Droste DW; Schmidt-Rimpler C; Wichter T; Dittrich R; Ritter M; Stypmann J; Ringelstein EB
Cerebrovasc Dis; 2004; 17(2-3):191-6. PubMed ID: 14707421
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]