These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

440 related articles for article (PubMed ID: 17458700)

  • 1. Models of flow-induced loading on blood cells in laminar and turbulent flow, with application to cardiovascular device flow.
    Quinlan NJ; Dooley PN
    Ann Biomed Eng; 2007 Aug; 35(8):1347-56. PubMed ID: 17458700
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.
    Barbaro V; Grigioni M; Daniele C; D'Avenio G
    Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monodimensional estimation of maximum Reynolds shear stress in the downstream flow field of bileaflet valves.
    Grigioni M; Daniele C; D'Avenio G; Barbaro V
    J Heart Valve Dis; 2002 May; 11(3):392-401. PubMed ID: 12056734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spatio-temporal flow analysis in bileaflet heart valve hinge regions: potential analysis for blood element damage.
    Simon HA; Dasi LP; Leo HL; Yoganathan AP
    Ann Biomed Eng; 2007 Aug; 35(8):1333-46. PubMed ID: 17431789
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rethinking turbulence in blood.
    Antiga L; Steinman DA
    Biorheology; 2009; 46(2):77-81. PubMed ID: 19458411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prediction of hemolysis in turbulent shear orifice flow.
    Tamagawa M; Akamatsu T; Saitoh K
    Artif Organs; 1996 Jun; 20(6):553-9. PubMed ID: 8817954
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Shear stress investigation across mechanical heart valve.
    Zhang P; Yeo JH; Qian P; Hwang NH
    ASAIO J; 2007; 53(5):530-6. PubMed ID: 17885324
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of eddy length scale on mechanical loading of blood cells in turbulent flow.
    Dooley PN; Quinlan NJ
    Ann Biomed Eng; 2009 Dec; 37(12):2449-58. PubMed ID: 19757062
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Estimation of viscous dissipative stresses induced by a mechanical heart valve using PIV data.
    Li CP; Lo CW; Lu PC
    Ann Biomed Eng; 2010 Mar; 38(3):903-16. PubMed ID: 20020213
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR; Yoganathan AP
    Life Support Syst; 1985; 3(4):283-312. PubMed ID: 4068753
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Turbulence detection in a stenosed artery bifurcation by numerical simulation of pulsatile blood flow using the low-Reynolds number turbulence model.
    Ghalichi F; Deng X
    Biorheology; 2003; 40(6):637-54. PubMed ID: 14610313
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of tilting disk, heart valve orientation on flow through a curved aortic model.
    Walker JD; Tiederman WG; Phillips WM
    J Biomech Eng; 1989 Aug; 111(3):229-32. PubMed ID: 2779188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies.
    Alemu Y; Bluestein D
    Artif Organs; 2007 Sep; 31(9):677-88. PubMed ID: 17725695
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An instrument for the measurement of in vitro velocity and turbulent shear stress in the immediate vicinity of prosthetic heart valves.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(1):47-62. PubMed ID: 2937981
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-dimensional color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro.
    Nygaard H; Giersiepen M; Hasenkam JM; Reul H; Paulsen PK; Rovsing PE; Westphal D
    J Biomech; 1992 Apr; 25(4):429-40. PubMed ID: 1583021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-component laser Doppler anemometer for measurement of velocity and turbulent shear stress near prosthetic heart valves.
    Woo YR; Yoganathan AP
    Med Instrum; 1985; 19(5):224-31. PubMed ID: 2932625
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of energy dissipation rate as a predictor of mechanical blood damage.
    Faghih MM; Sharp MK
    Artif Organs; 2019 Jul; 43(7):666-676. PubMed ID: 30588644
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of hemodynamic forces induced by mechanical heart valves: Reynolds vs. viscous stresses.
    Ge L; Dasi LP; Sotiropoulos F; Yoganathan AP
    Ann Biomed Eng; 2008 Feb; 36(2):276-97. PubMed ID: 18049902
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage?
    Steegers A; Paul R; Reul H; Rau G
    J Heart Valve Dis; 1999 May; 8(3):312-23. PubMed ID: 10399668
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.