These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 17465345)

  • 1. Bone density assessments of dental implant sites: 3. Bone quality evaluation during osteotomy and implant placement.
    Lee S; Gantes B; Riggs M; Crigger M
    Int J Oral Maxillofac Implants; 2007; 22(2):208-12. PubMed ID: 17465345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study.
    Fuster-Torres MÁ; Peñarrocha-Diago M; Peñarrocha-Oltra D; Peñarrocha-Diago M
    Int J Oral Maxillofac Implants; 2011; 26(5):1051-6. PubMed ID: 22010089
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: a clinical study.
    Salimov F; Tatli U; Kürkçü M; Akoğlan M; Oztunç H; Kurtoğlu C
    Clin Oral Implants Res; 2014 Sep; 25(9):1016-21. PubMed ID: 23772811
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets.
    Cehreli MC; Kökat AM; Comert A; Akkocaoğlu M; Tekdemir I; Akça K
    Clin Oral Implants Res; 2009 Oct; 20(10):1163-9. PubMed ID: 19681964
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of a modified stepped osteotomy on the primary stability of dental implants in low-density bone: a cadaver study.
    Boustany CM; Reed H; Cunningham G; Richards M; Kanawati A
    Int J Oral Maxillofac Implants; 2015; 30(1):48-55. PubMed ID: 25615915
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants.
    Isoda K; Ayukawa Y; Tsukiyama Y; Sogo M; Matsushita Y; Koyano K
    Clin Oral Implants Res; 2012 Jul; 23(7):832-6. PubMed ID: 21545533
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Can we predict the insertion torque using the bone density around the implant?
    Wada M; Suganami T; Sogo M; Maeda Y
    Int J Oral Maxillofac Surg; 2016 Feb; 45(2):221-5. PubMed ID: 26482639
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography.
    Aranyarachkul P; Caruso J; Gantes B; Schulz E; Riggs M; Dus I; Yamada JM; Crigger M
    Int J Oral Maxillofac Implants; 2005; 20(3):416-24. PubMed ID: 15973953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical aspects of primary implant stability: a human cadaver study.
    Turkyilmaz I; Sennerby L; McGlumphy EA; Tözüm TF
    Clin Implant Dent Relat Res; 2009 Jun; 11(2):113-9. PubMed ID: 18422713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tactile sense of the surgeon in determining bone density when placing dental implant.
    Rokn A; Rasouli Ghahroudi AA; Daneshmonfared M; Menasheof R; Shamshiri AR
    Implant Dent; 2014 Dec; 23(6):697-703. PubMed ID: 25347271
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla.
    Hakim SG; Glanz J; Ofer M; Steller D; Sieg P
    J Craniomaxillofac Surg; 2019 Mar; 47(3):461-467. PubMed ID: 30683621
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants.
    Turkyilmaz I; Tumer C; Ozbek EN; Tözüm TF
    J Clin Periodontol; 2007 Aug; 34(8):716-22. PubMed ID: 17635248
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
    Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
    Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.
    Marković A; Mišić T; Miličić B; Calvo-Guirado JL; Aleksić Z; Ðinić A
    Clin Oral Implants Res; 2013 Jul; 24(7):798-805. PubMed ID: 22469169
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bone density assessments of dental implant sites: 1. Quantitative computed tomography.
    Shahlaie M; Gantes B; Schulz E; Riggs M; Crigger M
    Int J Oral Maxillofac Implants; 2003; 18(2):224-31. PubMed ID: 12705300
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.
    Çehreli S; Arman-Özçırpıcı A
    Am J Orthod Dentofacial Orthop; 2012 Feb; 141(2):187-95. PubMed ID: 22284286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The possible association among bone density values, resonance frequency measurements, tactile sense, and histomorphometric evaluations of dental implant osteotomy sites: a preliminary study.
    Aksoy U; Eratalay K; Tözüm TF
    Implant Dent; 2009 Aug; 18(4):316-25. PubMed ID: 19667820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement.
    Turkyilmaz I; Tözüm TF; Tumer C; Ozbek EN
    J Oral Rehabil; 2006 Dec; 33(12):881-8. PubMed ID: 17168930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability.
    Sennerby L; Andersson P; Pagliani L; Giani C; Moretti G; Molinari M; Motroni A
    Clin Implant Dent Relat Res; 2015 Oct; 17(5):844-53. PubMed ID: 24373386
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conventional multi-slice computed tomography (CT) and cone-beam CT (CBCT) for computer-assisted implant placement. Part I: relationship of radiographic gray density and implant stability.
    Arisan V; Karabuda ZC; Avsever H; Özdemir T
    Clin Implant Dent Relat Res; 2013 Dec; 15(6):893-906. PubMed ID: 22251553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.