These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

386 related articles for article (PubMed ID: 17467872)

  • 21. An Enhanced Adaptive Filtering Method for Suppressing Cardiopulmonary Resuscitation Artifact.
    Gong Y; Gao P; Wei L; Dai C; Zhang L; Li Y
    IEEE Trans Biomed Eng; 2017 Feb; 64(2):471-478. PubMed ID: 27168590
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluating the quality of prehospital cardiopulmonary resuscitation by reviewing automated external defibrillator records and survival for out-of-hospital witnessed arrests.
    Ko PC; Chen WJ; Lin CH; Ma MH; Lin FY
    Resuscitation; 2005 Feb; 64(2):163-9. PubMed ID: 15680524
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A new defibrillator mode to reduce chest compression interruptions for health care professionals and lay rescuers: a pilot study in manikins.
    Barash DM; Raymond RP; Tan Q; Silver AE
    Prehosp Emerg Care; 2011; 15(1):88-97. PubMed ID: 21091330
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Enhancing the accuracy of shock advisory algorithms in automated external defibrillators during ongoing cardiopulmonary resuscitation using a cascade of CNNEDs.
    Nejad MPS; Kargin V; Hajeb-M S; Hicks D; Valentine M; Chon KH
    Comput Biol Med; 2024 Apr; 172():108180. PubMed ID: 38452474
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Sensitivity and specificity of an automated external defibrillator algorithm designed for pediatric patients.
    Atkins DL; Scott WA; Blaufox AD; Law IH; Dick M; Geheb F; Sobh J; Brewer JE
    Resuscitation; 2008 Feb; 76(2):168-74. PubMed ID: 17765384
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A method to differentiate between ventricular fibrillation and asystole during chest compressions using artifact-corrupted ECG alone.
    Zhang G; Wu T; Wan Z; Song Z; Yu M; Wang D; Li L; Chen F; Xu X
    Comput Methods Programs Biomed; 2017 Apr; 141():111-117. PubMed ID: 28241962
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The performance of a new shock advisory algorithm to reduce interruptions during CPR.
    Hu Y; Tang H; Liu C; Jing D; Zhu H; Zhang Y; Yu X; Zhang G; Xu J
    Resuscitation; 2019 Oct; 143():1-9. PubMed ID: 31377393
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Minimal interruption of cardiopulmonary resuscitation for a single shock as mandated by automated external defibrillations does not compromise outcomes in a porcine model of cardiac arrest and resuscitation.
    Ristagno G; Tang W; Russell JK; Jorgenson D; Wang H; Sun S; Weil MH
    Crit Care Med; 2008 Nov; 36(11):3048-53. PubMed ID: 18824916
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reduction of CPR artifacts in the ventricular fibrillation ECG by coherent line removal.
    Amann A; Klotz A; Niederklapfer T; Kupferthaler A; Werther T; Granegger M; Lederer W; Baubin M; Lingnau W
    Biomed Eng Online; 2010 Jan; 9():2. PubMed ID: 20053282
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A new way to analyze resuscitation quality by reviewing automatic external defibrillator data.
    Lin LY; Lo MT; Chiang WC; Lin C; Ko PC; Hsiung KH; Lin JL; Chen WJ; Ma MH
    Resuscitation; 2012 Feb; 83(2):171-6. PubMed ID: 22063728
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Improved neurological outcome with continuous chest compressions compared with 30:2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest.
    Ewy GA; Zuercher M; Hilwig RW; Sanders AB; Berg RA; Otto CW; Hayes MM; Kern KB
    Circulation; 2007 Nov; 116(22):2525-30. PubMed ID: 17998457
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Post-shock chest compression delays with automated external defibrillator use.
    Berg MD; Clark LL; Valenzuela TD; Kern KB; Berg RA
    Resuscitation; 2005 Mar; 64(3):287-91. PubMed ID: 15733755
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Deep Neural Network Approach for Continuous ECG-Based Automated External Defibrillator Shock Advisory System During Cardiopulmonary Resuscitation.
    Hajeb-M S; Cascella A; Valentine M; Chon KH
    J Am Heart Assoc; 2021 Mar; 10(6):e019065. PubMed ID: 33663222
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm.
    Husøy JH; Eilevstjønn J; Eftestøl T; Aase SO; Myklebust H; Steen PA
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1287-98. PubMed ID: 12450359
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Removal of cardiopulmonary resuscitation artifacts with an enhanced adaptive filtering method: an experimental trial.
    Gong Y; Yu T; Chen B; He M; Li Y
    Biomed Res Int; 2014; 2014():140438. PubMed ID: 24795878
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Analysis of ventricular fibrillation signals for the evaluation of defibrillation success in the treatment of ventricular fibrillation].
    Lederer W; Rheinberger K; Lischke V; Amann A
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2003 Dec; 38(12):787-94. PubMed ID: 14666442
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Bench study of the accuracy of a commercial AED arrhythmia analysis algorithm in the presence of electromagnetic interferences.
    Jekova I; Krasteva V; Ménétré S; Stoyanov T; Christov I; Fleischhackl R; Schmid JJ; Didon JP
    Physiol Meas; 2009 Jul; 30(7):695-705. PubMed ID: 19525573
    [TBL] [Abstract][Full Text] [Related]  

  • 38. See through ECG technology during cardiopulmonary resuscitation to analyze rhythm and predict defibrillation outcome.
    Affatato R; Li Y; Ristagno G
    Curr Opin Crit Care; 2016 Jun; 22(3):199-205. PubMed ID: 27031917
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A new method to estimate the amplitude spectrum analysis of ventricular fibrillation during cardiopulmonary resuscitation.
    Lo MT; Lin LY; Hsieh WH; Ko PC; Liu YB; Lin C; Chang YC; Wang CY; Young VH; Chiang WC; Lin JL; Chen WJ; Ma MH
    Resuscitation; 2013 Nov; 84(11):1505-11. PubMed ID: 23851191
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Shock advisory system with minimal delay triggering after end of chest compressions: accuracy and gained hands-off time.
    Didon JP; Krasteva V; Ménétré S; Stoyanov T; Jekova I
    Resuscitation; 2011 Dec; 82 Suppl 2():S8-15. PubMed ID: 22208180
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.