These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 17473401)

  • 1. A new expiratory support system for resolving air trapping in lungs during mechanical ventilation: a lung model study.
    Uchiyama A; Nishimura M; Amata M; Mashimo T; Fujino Y
    Technol Health Care; 2007; 15(3):213-20. PubMed ID: 17473401
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.
    Uchiyama A; Chang C; Suzuki S; Mashimo T; Fujino Y
    Anesth Analg; 2009 Aug; 109(2):434-40. PubMed ID: 19608814
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
    Fujino Y; Uchiyama A; Mashimo T; Nishimura M
    Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
    Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
    Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
    Hentschel R; Buntzel J; Guttmann J; Schumann S
    Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
    Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M
    Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of intratracheal airway pressure in ventilated neonatal piglets with endotracheal tube leaks.
    Nikischin W; Herber-Jonat S; von Bismarck P; Lange M; Grabitz R
    Crit Care Med; 2007 May; 35(5):1383-9. PubMed ID: 17414085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Catheters for tracheal gas insufflation.
    Adams AB
    Respir Care; 2001 Feb; 46(2):177-84. PubMed ID: 11175246
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of heliox on albuterol delivery by metered-dose inhaler in pediatric in vitro models of mechanical ventilation.
    Garner SS; Wiest DB; Stevens CE; Habib DM
    Pharmacotherapy; 2006 Oct; 26(10):1396-402. PubMed ID: 16999649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.
    Ivanov VA
    Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Compensating Artificial Airway Resistance via Active Expiration Assistance.
    Wirth S; Seywert L; Spaeth J; Schumann S
    Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bench study on active exhalation valve performance.
    Jiao GY; Newhart JW
    Respir Care; 2008 Dec; 53(12):1697-702. PubMed ID: 19025705
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of leak around the endotracheal tube on measurements of pulmonary compliance and resistance during mechanical ventilation: a lung model study.
    Kuo CY; Gerhardt T; Bolivar J; Claure N; Bancalari E
    Pediatr Pulmonol; 1996 Jul; 22(1):35-43. PubMed ID: 8856802
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pressure loss caused by pediatric endotracheal tubes during high-frequency-oscillation-ventilation.
    Schumann S; Krappitz M; Möller K; Hentschel R; Braun G; Guttmann J
    Respir Physiol Neurobiol; 2008 Jul; 162(2):132-7. PubMed ID: 18571997
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of automatic tube compensation in new-generation mechanical ventilators.
    Elsasser S; Guttmann J; Stocker R; Mols G; Priebe HJ; Haberthür C
    Crit Care Med; 2003 Nov; 31(11):2619-26. PubMed ID: 14605533
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An in vitro assessment of gas trapping during high frequency oscillation.
    Leipälä JA; Sharma A; Lee S; Milner AD; Greenough A
    Physiol Meas; 2005 Jun; 26(3):329-36. PubMed ID: 15798306
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulmonary cytokine responses during mechanical ventilation of noninjured lungs with and without end-expiratory pressure.
    Meier T; Lange A; Papenberg H; Ziemann M; Fentrop C; Uhlig U; Schmucker P; Uhlig S; Stamme C
    Anesth Analg; 2008 Oct; 107(4):1265-75. PubMed ID: 18806039
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Laboratory evaluation of the Vortran Automatic Resuscitator Model RTM.
    Babic MD; Chatburn RL; Stoller JK
    Respir Care; 2007 Dec; 52(12):1718-27. PubMed ID: 18028562
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Change in expiratory flow detects partial endotracheal tube obstruction in pressure-controlled ventilation.
    Kawati R; Vimlati L; Guttmann J; Hedenstierna G; Sjöstrand U; Schumann S; Lichtwarck-Aschoff M
    Anesth Analg; 2006 Sep; 103(3):650-7. PubMed ID: 16931676
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.