These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
159 related articles for article (PubMed ID: 17479325)
21. Intelligent, impedance-regulated, pulsed coagulation in a porcine renal artery model. Wallwiener C; Wallwiener M; Neunhoeffer E; Menger M; Isaacson K; Zubke W Fertil Steril; 2007 Jul; 88(1):206-11. PubMed ID: 17462642 [TBL] [Abstract][Full Text] [Related]
22. Efficacy and safety of 5-mm-diameter bipolar and ultrasonic shears for cutting carotid arteries of the hybrid pig. Mantke R; Halangk W; Habermann A; Peters B; Konrad S; Guenther M; Lippert H Surg Endosc; 2011 Feb; 25(2):577-85. PubMed ID: 20614136 [TBL] [Abstract][Full Text] [Related]
23. Perpendicular blood vessel seals are stronger than those made at an angle. Voegele AC; Korvick DL; Gutierrez M; Clymer JW; Amaral JF J Laparoendosc Adv Surg Tech A; 2013 Aug; 23(8):669-72. PubMed ID: 23755852 [TBL] [Abstract][Full Text] [Related]
25. Ultrasonic scalpel for sealing of the thoracic duct: evaluation of effectiveness in an animal model. Nakayama H; Ito H; Kato Y; Tsuboi M Interact Cardiovasc Thorac Surg; 2009 Sep; 9(3):399-401. PubMed ID: 19564208 [TBL] [Abstract][Full Text] [Related]
26. Pilot study of pulmonary arterial branch sealing using energy devices in an ex vivo model. Liberman M; Khereba M; Goudie E; Kazakov J; Thiffault V; Lafontaine E; Ferraro P J Thorac Cardiovasc Surg; 2014 Dec; 148(6):3219-23. PubMed ID: 25125207 [TBL] [Abstract][Full Text] [Related]
27. Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis. Matthews BD; Pratt BL; Backus CL; Kercher KW; Mostafa G; Lentzner A; Lipford EH; Sing RF; Heniford BT Am Surg; 2001 Sep; 67(9):901-6. PubMed ID: 11565773 [TBL] [Abstract][Full Text] [Related]
28. Pulmonary Artery Sealing Using the HARMONIC ACE+ Shears for Video-Assisted Thoracoscopic Surgery Lobectomy. Liberman M; Khereba M; Nasir B; Goudie E; Danino A; Giot JP; Nizard N; Hadjeres R; Thiffault V; Farrenq N; Ferraro P Ann Thorac Surg; 2015 Sep; 100(3):898-903; discussion 903-4. PubMed ID: 26209484 [TBL] [Abstract][Full Text] [Related]
30. [Bipolar Sealing of Lung Veins with 5 mm and 10 mm Instruments - Bursting Pressures Measured in an Ex-Vivo Model]. Kirschbaum A; Rössler C; Rexin P; Steinfeldt T; Bartsch DK; Mirow N Zentralbl Chir; 2016 Jun; 141(3):330-4. PubMed ID: 27027277 [TBL] [Abstract][Full Text] [Related]
31. Sealing vessels up to 7 mm in diameter solely with ultrasonic technology. Timm RW; Asher RM; Tellio KR; Welling AL; Clymer JW; Amaral JF Med Devices (Auckl); 2014; 7():263-71. PubMed ID: 25114600 [TBL] [Abstract][Full Text] [Related]
32. Effect of collagen and elastin content on the burst pressure of human blood vessel seals formed with a bipolar tissue sealing system. Latimer CA; Nelson M; Moore CM; Martin KE J Surg Res; 2014 Jan; 186(1):73-80. PubMed ID: 24035229 [TBL] [Abstract][Full Text] [Related]
33. Bipolar electrosurgical vessel-sealing device with compressive force monitoring. Chen RK; Chastagner MW; Geiger JD; Shih AJ J Biomech Eng; 2014 Jun; 136(6):061001. PubMed ID: 24658542 [TBL] [Abstract][Full Text] [Related]
34. A prospective study of in vivo and ex vivo sealing of the human inferior mesenteric artery using an electrothermal bipolar vessel-sealing device. Bibi S; Coralic J; Velchuru V; Quinteros F; Marecik S; Park J; Prasad LM J Laparoendosc Adv Surg Tech A; 2014 Jul; 24(7):471-4. PubMed ID: 24987843 [TBL] [Abstract][Full Text] [Related]
35. Ferromagnetic Heating for Vessel Sealing and Division: Utility and Comparative Study to Ultrasonic and Bipolar Technologies. Chen J; Manwaring PK; Scott RR; Manwaring KH; Glasgow RE Surg Innov; 2015 Aug; 22(4):329-37. PubMed ID: 25878211 [TBL] [Abstract][Full Text] [Related]
36. Variation in electrosurgical vessel seal quality along the length of a porcine carotid artery. Wyatt HL; Richards R; Pullin R; Yang TJ; Blain EJ; Evans SL Proc Inst Mech Eng H; 2016 Mar; 230(3):169-74. PubMed ID: 26743899 [TBL] [Abstract][Full Text] [Related]
37. Rapid sealing and cutting of porcine blood vessels, ex vivo, using a high-power, 1470-nm diode laser. Giglio NC; Hutchens TC; Perkins WC; Latimer C; Ward A; Nau WH; Fried NM J Biomed Opt; 2014 Mar; 19(3):38002. PubMed ID: 24658792 [TBL] [Abstract][Full Text] [Related]
38. Bipolar vessel sealing: instrument contamination and wear have little effect on seal quality and success in a porcine in vitro model. Wallwiener CW; Junginger SH; Zubke W; Brucker SY; Enderle MD; Neugebauer A; Schönfisch B; Wallwiener M Langenbecks Arch Surg; 2014 Oct; 399(7):863-71. PubMed ID: 25064363 [TBL] [Abstract][Full Text] [Related]
39. Vessel sealing comparison: old school is still hip. Tharakan SJ; Hiller D; Shapiro RM; Bose SK; Blinman TA Surg Endosc; 2016 Oct; 30(10):4653-8. PubMed ID: 26895898 [TBL] [Abstract][Full Text] [Related]
40. Can LigaSure seal and divide the small bowel? Salameh JR; Schwartz JH; Hildebrandt DA Am J Surg; 2006 Jun; 191(6):791-3. PubMed ID: 16720150 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]