These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 17487106)

  • 1. Assessment of dermal ethanol emission sensors: experimental design.
    Webster G; Gabler HC
    Biomed Sci Instrum; 2007; 43():348-53. PubMed ID: 17487106
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Studies on a wearable, electronic, transdermal alcohol sensor.
    Swift RM; Martin CS; Swette L; LaConti A; Kackley N
    Alcohol Clin Exp Res; 1992 Aug; 16(4):721-5. PubMed ID: 1530135
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validity of transdermal alcohol monitoring: fixed and self-regulated dosing.
    Sakai JT; Mikulich-Gilbertson SK; Long RJ; Crowley TJ
    Alcohol Clin Exp Res; 2006 Jan; 30(1):26-33. PubMed ID: 16433729
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat.
    Gamella M; Campuzano S; Manso J; González de Rivera G; López-Colino F; Reviejo AJ; Pingarrón JM
    Anal Chim Acta; 2014 Jan; 806():1-7. PubMed ID: 24331037
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An accurate amperometric glucose sensor based glucometer with eliminated cross-sensitivity.
    Bani Amer MM
    J Med Eng Technol; 2002; 26(5):208-13. PubMed ID: 12487712
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Temperature measurement in breath alcohol analysis].
    Schoknecht G; Kophamel B; Barduhn B
    Blutalkohol; 1989 May; 26(3):137-49. PubMed ID: 2736086
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contribution of serum ethanol concentration to the osmol gap: a prospective volunteer study.
    Carstairs SD; Suchard JR; Smith T; Simon LV; Kalynych CJ; Shimada M; Tanen DA
    Clin Toxicol (Phila); 2013 Jun; 51(5):398-401. PubMed ID: 23641935
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig.
    Gourzi M; Rouane A; Guelaz R; Nadi M; Jaspard F
    J Med Eng Technol; 2003; 27(6):276-81. PubMed ID: 14602519
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Isopropanol interference with breath alcohol analysis: a case report.
    Logan BK; Gullberg RG; Elenbaas JK
    J Forensic Sci; 1994 Jul; 39(4):1107-11. PubMed ID: 8064270
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Experiences with the SD3 Alcometer in police use--comparison between breath alcohol and blood alcohol concentrations].
    Schulz G; Schütz H
    Beitr Gerichtl Med; 1988; 46():185-8. PubMed ID: 3178660
    [No Abstract]   [Full Text] [Related]  

  • 11. [Determination of alcohol in exhaled breath may give wrong values. Warning for unspecific testing with some instruments].
    Helander A; Walther RI; Jones AW
    Lakartidningen; 2010 Jan 20-26; 107(3):110-2. PubMed ID: 20225686
    [No Abstract]   [Full Text] [Related]  

  • 12. [Breath alcohol measuring equipment: principles for calibration].
    Schoknecht G; Barduhn B
    Blutalkohol; 1995 Mar; 32(2):74-82. PubMed ID: 7748525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Experiences with the "Lion Alcometer AE-D3" in determining blood alcohol and breath alcohol].
    Kaatsch HJ; Schütz H
    Beitr Gerichtl Med; 1988; 46():175-83. PubMed ID: 3178659
    [No Abstract]   [Full Text] [Related]  

  • 14. Review of Ethanol Intoxication Sensing Technologies and Techniques.
    Paprocki S; Qassem M; Kyriacou PA
    Sensors (Basel); 2022 Sep; 22(18):. PubMed ID: 36146167
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Reevaluation of breath alcohol concentration with Alcotest 7410].
    Clasing D; Bohn G; Brackemeyer U
    Blutalkohol; 1992 Mar; 29(2):130-3. PubMed ID: 1581023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The kinetics of transdermal ethanol exchange.
    Anderson JC; Hlastala MP
    J Appl Physiol (1985); 2006 Feb; 100(2):649-55. PubMed ID: 16239611
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Identification of melanoma with a gas sensor array.
    D'Amico A; Bono R; Pennazza G; Santonico M; Mantini G; Bernabei M; Zarlenga M; Roscioni C; Martinelli E; Paolesse R; Di Natale C
    Skin Res Technol; 2008 May; 14(2):226-36. PubMed ID: 18412567
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Postmortem blood and vitreous humor ethanol concentrations in a victim of a fatal motor vehicle crash.
    Hardin GG
    J Forensic Sci; 2002 Mar; 47(2):402-3. PubMed ID: 11908619
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The application of force-sensing resistor sensors for measuring forces developed by the human hand.
    Nikonovas A; Harrison AJ; Hoult S; Sammut D
    Proc Inst Mech Eng H; 2004; 218(2):121-6. PubMed ID: 15116899
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Recommendation for a legally valid breath alcohol measurement].
    Schoknecht G; Kophamel-Röder B; Fleck K
    Blutalkohol; 1991 Jul; 28(4):210-23. PubMed ID: 1910659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.