These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Auditory steady-state responses for children with severe to profound hearing loss. Swanepoel D; Hugo R; Roode R Arch Otolaryngol Head Neck Surg; 2004 May; 130(5):531-5. PubMed ID: 15148172 [TBL] [Abstract][Full Text] [Related]
3. Establishing normal hearing with the dichotic multiple-frequency auditory steady-state response compared to an auditory brainstem response protocol. Swanepoel D; Schmulian D; Hugo R Acta Otolaryngol; 2004 Jan; 124(1):62-8. PubMed ID: 14977080 [TBL] [Abstract][Full Text] [Related]
4. Auditory steady-state responses to bone conduction stimuli in children with hearing loss. Swanepoel de W; Ebrahim S; Friedland P; Swanepoel A; Pottas L Int J Pediatr Otorhinolaryngol; 2008 Dec; 72(12):1861-71. PubMed ID: 18963045 [TBL] [Abstract][Full Text] [Related]
5. Short report: establishing normal hearing for infants with the auditory steady-state response. Swanepoel de W; Steyn K S Afr J Commun Disord; 2005; 52():36-9. PubMed ID: 17902400 [TBL] [Abstract][Full Text] [Related]
6. Prognostic validity of dichotic multiple frequencies auditory steady-state responses versus distortion product otoacoustic emissions in hearing screening of high risk neonates. Mahmoudian S; Farhadi M; Kadivar M; Ghalehbaghi B; Rahimi F; Hemami MR; Kamrava SK; Asghari A; Amintehran E; Mohagheghi P Int J Pediatr Otorhinolaryngol; 2011 Sep; 75(9):1109-16. PubMed ID: 21719120 [TBL] [Abstract][Full Text] [Related]
7. Auditory steady-state response and auditory brainstem response thresholds in children. Swanepoel D; Ebrahim S Eur Arch Otorhinolaryngol; 2009 Feb; 266(2):213-9. PubMed ID: 18560866 [TBL] [Abstract][Full Text] [Related]
8. Comparison of auditory steady-state responses and auditory brainstem responses in audiometric assessment of adults with sensorineural hearing loss. Lin YH; Ho HC; Wu HP Auris Nasus Larynx; 2009 Apr; 36(2):140-5. PubMed ID: 18620826 [TBL] [Abstract][Full Text] [Related]
9. Assessing Agreement between Frequency-Specific Chirp Auditory Steady-State Response and Pure Tone Audiometry in Adults by Intraclass Correlation Coefficient. Chen M; Wei Y; Wang X; Liu L; Liu M; Jiang G; Wei F ORL J Otorhinolaryngol Relat Spec; 2022; 84(1):30-38. PubMed ID: 33979798 [TBL] [Abstract][Full Text] [Related]
10. A comparison of 40 Hz auditory steady-state response (ASSR) and cortical auditory evoked potential (CAEP) thresholds in awake adult subjects. Tomlin D; Rance G; Graydon K; Tsialios I Int J Audiol; 2006 Oct; 45(10):580-8. PubMed ID: 17062499 [TBL] [Abstract][Full Text] [Related]
11. Validation of multi-channel auditory steady-state response in adults with sensorineural hearing loss. Lin YH; Chen PR; Hsu CJ; Wu HP J Laryngol Otol; 2009 Jan; 123(1):38-44. PubMed ID: 18452631 [TBL] [Abstract][Full Text] [Related]
12. Estimating audiometric thresholds using simultaneous acquisition of ASSR and ABR from QASSR in patients with sensorineural hearing loss. Lachowska M; Bohórquez J; Özdamar Ö; Niemczyk K Int J Audiol; 2016 Dec; 55(12):748-757. PubMed ID: 27686167 [TBL] [Abstract][Full Text] [Related]
13. The ASSR: clinical application in normal-hearing and hearing-impaired infants and adults, comparison with the click-evoked ABR and pure-tone audiometry. Scherf F; Brokx J; Wuyts FL; Van de Heyning PH Int J Audiol; 2006 May; 45(5):281-6. PubMed ID: 16717018 [TBL] [Abstract][Full Text] [Related]
14. Dichotic multiple-frequency auditory steady-state responses in evaluating the hearing thresholds of occupational noise-exposed workers. Hsu RF; Chen SS; Lu SN; Ho CK; Lin HF Kaohsiung J Med Sci; 2011 Aug; 27(8):330-5. PubMed ID: 21802644 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of residual hearing in cochlear implants candidates using auditory steady-state response. Ramos HF; Grasel SS; Beck RM; Takahashi-Ramos MT; Ramos BF; de Almeida ER; Bento RF; de Brito Neto R Acta Otolaryngol; 2015 Mar; 135(3):246-53. PubMed ID: 25649884 [TBL] [Abstract][Full Text] [Related]
16. A controlled comparison of auditory steady-state responses and pure-tone audiometry in patients with hearing loss. Wadhera R; Hernot S; Gulati SP; Kalra V Ear Nose Throat J; 2017; 96(10-11):E47-E52. PubMed ID: 29121385 [TBL] [Abstract][Full Text] [Related]
17. Narrow band CE-Chirp auditory steady-state response is more reliable than the conventional ASSR in predicting the behavioral hearing threshold. Lee MY; Ahn SY; Lee HJ; Jung JY; Rhee CK; Suh MW Auris Nasus Larynx; 2016 Jun; 43(3):259-68. PubMed ID: 26526641 [TBL] [Abstract][Full Text] [Related]
18. [The correlativity between the threshold acquired with ASSR and PTA]. Yang XP; Fan LH; Zhou XR Fa Yi Xue Za Zhi; 2008 Oct; 24(5):321-4. PubMed ID: 18979911 [TBL] [Abstract][Full Text] [Related]
19. Multiple-ASSR thresholds in infants and young children with hearing loss. Van Maanen A; Stapells DR J Am Acad Audiol; 2010 Sep; 21(8):535-45. PubMed ID: 21034700 [TBL] [Abstract][Full Text] [Related]
20. [The estimation of behavioral audiograms, auditory brainstem response (ABR) thresholds and auditory steady-state response (ASSR) thresholds of young adults with normal hearing]. Szymańska A; Gryczyński M; Pajor A Otolaryngol Pol; 2008; 62(6):735-9. PubMed ID: 19205522 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]