These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 17494778)

  • 1. Is brachial artery peak velocity variation ready for prime time?
    Eikermann M; Magder S; Malhotra A
    Chest; 2007 May; 131(5):1279-81. PubMed ID: 17494778
    [No Abstract]   [Full Text] [Related]  

  • 2. Radial artery pulse pressure variation correlates with brachial artery peak velocity variation in ventilated subjects when measured by internal medicine residents using hand-carried ultrasound devices.
    Brennan JM; Blair JE; Hampole C; Goonewardena S; Vasaiwala S; Shah D; Spencer KT; Schmidt GA
    Chest; 2007 May; 131(5):1301-7. PubMed ID: 17494781
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A pilot study of the relationship between Doppler-estimated carotid and brachial artery flow and cardiac index.
    Weber U; Glassford NJ; Eastwood GM; Bellomo R; Hilton AK
    Anaesthesia; 2015 Oct; 70(10):1140-7. PubMed ID: 26010229
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Central pressure and pulse wave amplification in the upper limb.
    O'Rourke MF; Adji A
    Hypertension; 2010 Jan; 55(1):e1-2; author reply e3. PubMed ID: 19948987
    [No Abstract]   [Full Text] [Related]  

  • 5. Effect of SR manipulation on conduit artery dilation in humans.
    Carter HH; Dawson EA; Birk GK; Spence AL; Naylor LH; Cable NT; Thijssen DH; Green DJ
    Hypertension; 2013 Jan; 61(1):143-50. PubMed ID: 23150517
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Role of pulse pressure amplification in arterial hypertension: experts' opinion and review of the data.
    Avolio AP; Van Bortel LM; Boutouyrie P; Cockcroft JR; McEniery CM; Protogerou AD; Roman MJ; Safar ME; Segers P; Smulyan H
    Hypertension; 2009 Aug; 54(2):375-83. PubMed ID: 19564542
    [No Abstract]   [Full Text] [Related]  

  • 7. Caution using brachial systolic pressure to calibrate radial tonometric pressure waveforms: lessons from invasive study.
    Davies JE; Shanmuganathan M; Francis DP; Mayet J; Hackett DR; Hughes AD
    Hypertension; 2010 Jan; 55(1):e4. PubMed ID: 19948982
    [No Abstract]   [Full Text] [Related]  

  • 8. The aortic pressure wave in aortic stenosis.
    O'Rourke MF
    J Hypertens; 2009 May; 27(5):1104; author reply 1105. PubMed ID: 19390351
    [No Abstract]   [Full Text] [Related]  

  • 9. Blood flow in the brachial artery increases after intense cycling exercise.
    Medbø JI; Hisdal J; Stranden E
    Scand J Clin Lab Invest; 2009; 69(7):752-63. PubMed ID: 19929718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of a systolic parameter, defined as the ratio of right brachial pre-ejection period to ejection time, on the relationship between brachial-ankle pulse wave velocity and left ventricular diastolic function.
    Hsu PC; Lin TH; Lee CS; Chu CY; Su HM; Voon WC; Lai WT; Sheu SH
    Hypertens Res; 2011 Apr; 34(4):462-7. PubMed ID: 21228788
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of the Arteriograph working principle: questions still remain.
    Trachet B; Reymond P; Kips J; Vermeersch S; Swillens A; Stergiopulos N; Segers P
    J Hypertens; 2011 Mar; 29(3):619; author reply 620. PubMed ID: 21317726
    [No Abstract]   [Full Text] [Related]  

  • 12. Influence of applied brachial recording forces on pulse wave velocity and transmission in the brachio-radial arterial segment.
    Driscoll MD; Arnold JM; Marchiori GE; Sherebrin MH
    Clin Invest Med; 1995 Dec; 18(6):435-48. PubMed ID: 8714787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationship between radial and central arterial pulse wave and evaluation of central aortic pressure using the radial arterial pulse wave.
    Takazawa K; Kobayashi H; Shindo N; Tanaka N; Yamashina A
    Hypertens Res; 2007 Mar; 30(3):219-28. PubMed ID: 17510503
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow-mediated dilation.
    Parker BA; Proctor DN
    J Appl Physiol (1985); 2005 Oct; 99(4):1620. PubMed ID: 16160023
    [No Abstract]   [Full Text] [Related]  

  • 15. Simplified distributed-parameter model of brachial-radial arteries for noninvasive determination of mechanical characteristics of vessel.
    Ferreira AS; Filho JB; Souza MN
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1814-7. PubMed ID: 17945669
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow-mediated vasodilation partially reflects nitric oxide-mediated endothelial function.
    Linke A; Erbs S; Hambrecht R
    J Appl Physiol (1985); 2005 Oct; 99(4):1622. PubMed ID: 16160025
    [No Abstract]   [Full Text] [Related]  

  • 17. Ankle brachial pressure index.
    Jones JG
    J R Soc Med; 2007 Mar; 100(3):117. PubMed ID: 17339302
    [No Abstract]   [Full Text] [Related]  

  • 18. Regulation of vascular tone and pulse wave velocity in human muscular conduit arteries: selective effects of nitric oxide donors to dilate muscular arteries relative to resistance vessels.
    Fok H; Jiang B; Clapp B; Chowienczyk P
    Hypertension; 2012 Nov; 60(5):1220-5. PubMed ID: 23045465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flawed measurement of brachial tonometry for calculating aortic pressure?
    O'Rourke MF; Takazawa K
    Hypertension; 2009 Nov; 54(5):e131; author reply e132. PubMed ID: 19752289
    [No Abstract]   [Full Text] [Related]  

  • 20. Accuracy of nongeometric pulsed Doppler cardiac output.
    Spodick DH
    Am J Cardiol; 1994 Feb; 73(5):421. PubMed ID: 8109566
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.