  • 21. Noninvasive measurement of scattering anisotropy in turbid materials by nonnormal incident illumination.
    Joshi N; Donner C; Jensen HW
    Opt Lett; 2006 Apr; 31(7):936-8. PubMed ID: 16599217
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of a radiative transfer equation and diffusion approximation hybrid forward solver for fluorescence molecular imaging.
    Gorpas D; Andersson-Engels S
    J Biomed Opt; 2012 Dec; 17(12):126010. PubMed ID: 23208221
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An Adaptive Multigrid method for modeling photon transport through biological tissues in bioluminescence tomography.
    Liu K; Tian J; Wang P; Liu D; Lv Y; Xu M; Qin C
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():462-5. PubMed ID: 19162693
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hybrid radiative-transfer-diffusion model for optical tomography.
    Tarvainen T; Vauhkonen M; Kolehmainen V; Kaipio JP
    Appl Opt; 2005 Feb; 44(6):876-86. PubMed ID: 15751677
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Simple time-domain optical method for estimating the depth and concentration of a fluorescent inclusion in a turbid medium.
    Hall D; Ma G; Lesage F; Wang Y
    Opt Lett; 2004 Oct; 29(19):2258-60. PubMed ID: 15524373
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Simulation of diffuse photon migration in tissue by a Monte Carlo method derived from the optical scattering of spheroids.
    Hart VP; Doyle TE
    Appl Opt; 2013 Sep; 52(25):6220-9. PubMed ID: 24085080
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Recovery of hemoglobin oxygen saturation and intrinsic fluorescence with a forward-adjoint model.
    Finlay JC; Foster TH
    Appl Opt; 2005 Apr; 44(10):1917-33. PubMed ID: 15813528
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Diffuse photon propagation in multilayered geometries.
    Sikora J; Zacharopoulos A; Douiri A; Schweiger M; Horesh L; Arridge SR; Ripoll J
    Phys Med Biol; 2006 Feb; 51(3):497-516. PubMed ID: 16424578
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calculation of photon path changes due to scatter in Monte Carlo simulations.
    Phillips JP; Kyriacou PA; Jones DP
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():4959-62. PubMed ID: 21096672
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Combined reconstruction of fluorescent and optical parameters using time-resolved data.
    Soloviev VY; D'Andrea C; Valentini G; Cubeddu R; Arridge SR
    Appl Opt; 2009 Jan; 48(1):28-36. PubMed ID: 19107168
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Experimental validation of Monte Carlo modeling of fluorescence in tissues in the UV-visible spectrum.
    Liu Q; Zhu C; Ramanujam N
    J Biomed Opt; 2003 Apr; 8(2):223-36. PubMed ID: 12683848
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Influence of photon energy cuts on PET Monte Carlo simulation results.
    Mitev K; Gerganov G; Kirov AS; Schmidtlein CR; Madzhunkov Y; Kawrakow I
    Med Phys; 2012 Jul; 39(7):4175-86. PubMed ID: 22830751
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Polarized light propagation in multiply scattering media exhibiting both linear birefringence and optical activity: Monte Carlo model and experimental methodology.
    Wood MF; Guo X; Vitkin IA
    J Biomed Opt; 2007; 12(1):014029. PubMed ID: 17343504
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Anisotropic diffusive transport: connecting microscopic scattering and macroscopic transport properties.
    Alerstam E
    Phys Rev E Stat Nonlin Soft Matter Phys; 2014 Jun; 89(6):063202. PubMed ID: 25019904
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Scattering of light by multiple dielectric cylinders: comparison of radiative transfer and Maxwell theory.
    Schäfer J; Kienle A
    Opt Lett; 2008 Oct; 33(20):2413-5. PubMed ID: 18923640
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Mesh-based enhancement schemes in diffuse optical tomography.
    Gu X; Xu Y; Jiang H
    Med Phys; 2003 May; 30(5):861-9. PubMed ID: 12772994
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Diffuse photon density wave measurements and Monte Carlo simulations.
    Kuzmin VL; Neidrauer MT; Diaz D; Zubkov LA
    J Biomed Opt; 2015 Oct; 20(10):105006. PubMed ID: 26465614
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Experimental and simulated angular profiles of fluorescence and diffuse reflectance emission from turbid media.
    Gebhart SC; Mahadevan-Jansen A; Lin WC
    Appl Opt; 2005 Aug; 44(23):4884-901. PubMed ID: 16114526
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Modeling and experimental verification for a broad beam light transport in optical tomography.
    Janunts E; Pöschinger T; Eisa F; Langenbucher A
    Z Med Phys; 2010; 20(4):277-86. PubMed ID: 20889320
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of excitation light rejection on forward model mismatch in optical tomography.
    Hwang K; Pan T; Joshi A; Rasmussen JC; Bangerth W; Sevick-Muraca EM
    Phys Med Biol; 2006 Nov; 51(22):5889-902. PubMed ID: 17068371
    [TBL] [Abstract][Full Text] [Related]  